FIRE ALARM SYSTEM DEVICE LEGEND <br />SYMBOL DESRIPTION COMMENT PRODUCT I.D. MOUNTING HEIGHT ELEC. BOXMj <br />FIRE ALARM CONTROL <br />VIGILANT SERIES VS1-RD <br />72" AFF TO TOP <br />FACP <br />PANEL WITH DACT <br />OF CONTAINER <br />MFR. <br />FIRE ALARM REMOTE <br />VIGILANT SERIES RLCD-R <br />60" AFF TO TOP <br />FAAP <br />ANNUCIATOR PANEL <br />OF CONTAINER <br />MFR. <br />BPS <br />FIRE ALARM REMOTE <br />VIGILANT SERIES MIRBPS6A <br />BESIDE FACP <br />MFR. <br />POWER SUPPLY <br />ADDRESSABLE MANUAL <br />VIGILANT SERIES <br />42" TO 48" AFF <br />PULL STATION <br />GSA-M278 DOUBLE ACTION <br />NOTE 2 <br />C <br />z <br />O <br />ADDRESSABLE <br />VIGILANT SERIES <br />CEILING <br />B <br />SMOKE DETECTOR <br />V-PD WITH K1-SB BASE <br />MOUNT <br />ADDRESSABLE SUPP./ <br />VIGILANT SERIES GSA -SD <br />DUCT <br />S/R <br />RTN. SIDE DUCT DET. <br />WITH SD-T60 SAMPLING TUBES <br />MOUNTED <br />D <br />R <br />DUCT DETECTOR <br />VIGILANT SERIES GSA -SD <br />CEILING <br />C <br />REMOTE TEST SWITCH <br />WITH SD-TRM <br />MOUNT <br />0 <br />ADDRESSABLE <br />VIGILANT SERIES <br />PROVIDE DRY <br />E <br />MONITOR MODULE <br />GSA-CT1 <br />ENCLOSURES <br />❑M <br />ADDRESSABLE DUAL <br />VIGILANT SERIES <br />PROVIDE DRY <br />E <br />2 <br />MONITOR MODULE <br />GSA-CT2 <br />ENCLOSURES <br />C R <br />ADDRESSABLE <br />VIGILANT SERIES <br />PROVIDE DRY <br />E <br />RELAY MODULE <br />GSA-CR <br />ENCLOSURES <br />0 F <br />SPRINKLER <br />FURNISHED BY OTHERS <br />FIELD LOCATE <br />D <br />�--do-� <br />FLOW SWITCH <br />MONITORED BY NEW FACP <br />PER FLOOR PLANS <br />T <br />SPRINKLER <br />FURNISHED BY OTHERS <br />FIELD LOCATE <br />TAMPER SWITCH <br />MONITORED BY NEW FACP <br />PER FLOOR PLANS <br />D <br />WALL MOUNT <br />WHEELOCK EXCEDER LHS3 SERIES <br />82" AFF TO <br />C <br />HORN STROBE <br />(*) CANDELA RATING <br />BOTTOM OF LENS <br />CEILING MOUNT <br />WHEELOCK EXCEDER LHSC3 SERIES <br />CEILING <br />HORN STROBE <br />(*) CANDELA RATING <br />MOUNT <br />C <br />CLG. <br />MOUNT W.P. <br />WHEELOCK ASWP-2475W-FR SERIES <br />82" AFF TO <br />�WALL <br />p <br />HORN STROBE <br />115 CANDELA RATING <br />BOTTOM OF LENS <br />WBB <br />WALL MOUNT W.P. <br />WHEELOCK ASWP-2475C-FR SERIES <br />82" AFF TO <br />HORN STROBE <br />115 CANDELA RATING <br />BOTTOM OF LENS <br />WBB <br />WP CLG. <br />CEILING MOUNT <br />WHEELOCK EXCEDER LSTC3 SERIES <br />CEILING <br />C <br />STROBE <br />(*) CANDELA RATING <br />MOUNT <br />CLG. <br />S�-� <br />FIRE ALARM 120VAC <br />DITEK DTK-120HW SERIES <br />FIELD LOCATED <br />120 <br />CIRCUIT PROTECTOR <br />AT FACP/BPS <br />D <br />MFR. DENOTES BACKBOX FURNISHED BY MANUFACTURER <br />AFF DENOTES ABOVE FINISHED FLOOR <br />WBB DENOTES WEATHERPROOF BACKBOX <br />BACKBOXES <br />REQUIRED BY OTHERS <br />2-1 /8" 4>, SQ 2-1 /8" 1-1 /2,> <br />DEEP DEEP DEEP <br />4" SQ. 1-1/2" BLANK SINGLE 4-1 1 /16" 4-1 1 /16" OCTAGON <br />EXT. RING PLATE GANG BOX SQ. BOX EXT. RING BOX <br />BACKBOX SCHEDULE <br />A - 4" BOX WITH SINGLE GANG RING <br />B - 4" BOX WITH ROUND RING OR OCTAGON BOX <br />C - 4" BOX 2-1 /8" DEEP WITH SGPR <br />D - 4" BOX ADJACENT FLEX TO DEVICE <br />E - 4" BOX 2 1/8" DEEP WITH EXTENSION BOX <br />GENERAL NOTES <br />SYSTEM INSTALLATION IN ACCORDANCE WITH <br />6TH EDITION (2017) OF THE FLORIDA BUILDING CODE <br />FLORIDA SPECIFIC ADDITION OF NFPA 1, THE FIRE CODE (2015) <br />NATIONAL ELECTRIC CODE (2014 EDITION) NFPA 72 (2013 EDITION) <br />NATIONAL FIRE ALARM SIGNALING CODE - FLORIDA SPECIFIC EDITION OF NFPA 101 <br />NFPA 101 (2015 EDITION) <br />FLORIDA ADMINISTRATIVE CODE 61 G15-32 <br />ALL OTHER CODES MANDATED BY THE LOCAL AUTHORITY HAVING JURISDICTION <br />1) FIRE ALARM SYSTEM WIRING: <br />STYLE B (CLASS B) INITIATION DEVICE CKTS. <br />STYLE Y (CLASS B) NOTIFICATION APPLIANCE CKTS. <br />STYLE 4 (CLASS B) ADDRESSABLE SIGNALING LINE <br />2) LOCKBOX TO BE MOUNTED OUTSIDE OF THE BUILDING WITHIN 6' OF <br />PRIMARY ENTRANCE DOOR AND AT A HEIGHT NOT TO EXCEED 12' AFF <br />.NOR BE LESS THAN 8' AFF TO BOTTOM OF BOX. <br />KEYBOX SHALL BE ZONED INDEPENDENTLY IF REQUIRED BY THE LOCAL AUTHORITY <br />FIRE ALARM SYSTEM BATTERY CALCULATION <br />VIGILANT SERIES VS1 -RD (FACP) <br />ITEM <br />QTY <br />DESCRIPTION <br />STANDBY <br />ALARM <br />STANDBY <br />ALARM <br />per unit <br />per unit <br />Total <br />Total <br />A 1 MASTER CONTROLLER <br />0.155 <br />0.204 <br />0.155 <br />0.204 <br />B 1 REMOTE ANNUCIATOR <br />0.036 <br />0.146 <br />0.036 <br />0.146 <br />C 18 ADDRESSABLE DEVICES <br />0.0005 <br />0.0005 <br />0.009 <br />0.009 <br />D 1 FULL LOAD NOTIFICATION <br />0.000 <br />3.750 <br />0.000 <br />3.750 <br />E 3 AUX. 24VDC RELAY <br />0.000 <br />0.015 <br />0.000 <br />0.045 <br />TOTAL DRAW AMPS <br />0.200 <br />4.154 <br />STANDBY FOR 24 HOURS AMPS <br />4.800 <br />ALARM FOR 5 MINUTES AMPS <br />.347 <br />TOTAL BATTERY IN AMPS REQUIRED <br />5.147 <br />X 1.2 FACTOR <br />6.177 <br />BATTERIES SUPPLIED 7.0 AMP HOUR <br />NOTIFICATION CIRCUITS FUSED AT 2.5 AMPS <br />VIGILANT SERIES MIRBPS6A (PCPs) <br />ITEM <br />QTY <br />DESCRIPTION <br />STANDBY <br />ALARM <br />STANDBY <br />ALARM <br />per unit <br />per unit <br />Total <br />Total <br />A 1 MASTER CONTROLLER <br />0.175 <br />0.270 <br />0.175 <br />0.270 <br />B NOTIFICATION CIRCUIT 1 <br />0.000 <br />1.022 <br />0.000 <br />1.022 <br />C 1 NOTIFICATION CIRCUIT 2 <br />0.000 <br />1.109 <br />0.000 <br />1.109 <br />p 1 NOTIFICATION CIRCUIT 3 <br />0.000 <br />1.511 <br />0.000 <br />1.511 <br />E 1 NOTIFICATION CIRCUIT 4 (SPARE) <br />0.000 <br />0.000 <br />0.000 <br />0.000 <br />TOTAL DRAW AMPS <br />0.175 <br />3.912 <br />STANDBY FOR 24 HOURS AMPS <br />4.200 <br />ALARM FOR 5 MINUTES AMPS <br />.326 <br />TOTAL BATTERY IN AMPS REQUIRED <br />4.526 <br />X 1.2 FACTOR <br />5.432 <br />BATTERIES SUPPLIED 7.0 AMP HOUR <br />NOTIFICATION CIRCUITS FUSED AT 3.0 AMPS <br />ELECTRICAL/MECHANICAL ROOM <br />nRKA cVCTFt\A RIcr-R 111A(_RANA <br />00 <br />MAIN ENTRANCE <br />001 <br />FIRE ALARM FUNCTIONAL MATRIX:..Of <br />Of U-3 <br />m <br />2f -cc <br />M <br />W cn <br />W <br />CUj <br />cn <br />/ <br />CONTROL UNIT ANNUNCIATION <br />NOTIFICATION <br />SUPPLEMENTARY <br />o <br />Q <br />r <br />o <br />o <br />U <br />J <br />� <br />J <br />J <br />Q <br />O <br />Q <br />Z <br />I - <br />ALL WORK SHALL Ct:MFLY WITH <br />NFFA CODES AND STANDARDS If <br />REVIEW DATE <br />CITY OF ZEPHYRHIL` lS <br />FIRE AND LIFE SAFETY EXAMINER_______ <br />P.E. STAMP <br />1 <br />o <br />• <br />• <br />yy . <br />y z <br />rrr <br />ty;� <br />� <br />q <br />Q <br />O <br />C <br />DRAWN BY: DQDD <br />APPROVED BY: <br />DATE: 11 /21 /19 <br />SCALE: AS INDICATED <br />PROJECT N0: <br />Al <br />DEVICE LEGEND <br />BATTERY CALCS. <br />RISER DIAGRAM <br />FA-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.