My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2801 E SR 60 (2)
Zephyrhills
>
Building Department
>
Building Plans
>
2801 E SR 60 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:46:06 AM
Creation date
2/19/2025 8:18:18 AM
Metadata
Fields
Template:
Building Plans
Street #
2801
Location
E SR 60
Contractor
JJ Consulting Group, Inc
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE ALARM SYSTEM DEVICE LEGEND <br />SYMBOL DESRIPTION COMMENT PRODUCT I.D. MOUNTING HEIGHT ELEC. BOX <br />FIRE ALARM CONTROL <br />VIGILANT SERIES VS1-RD <br />72" AFF TO TOP <br />FRCP <br />PANEL WITH DACT <br />OF CONTAINER <br />MFR. <br />FIRE ALARM REMOTE <br />VIGILANT SERIES RLCD-R <br />60" AFF TO TOP <br />FAAP <br />ANNUCIATOR PANEL <br />OF CONTAINER <br />MFR. <br />FIRE ALARM REMOTE <br />VIGILANT SERIES MIRBPS6A <br />BESIDE FACP <br />FEP <br />POWER SUPPLY <br />MFR. <br />F❑ <br />ADDRESSABLE MANUAL <br />VIGILANT SERIES <br />42" TO 48" AFF <br />PULL STATION <br />GSA-M278 DOUBLE ACTION <br />NOTE 2 <br />C <br />ADDRESSABLE <br />VIGILANT SERIES <br />CEILING <br />0 <br />SMOKE DETECTOR <br />V-PD WITH K1-SB BASE <br />MOUNT <br />B <br />�2 <br />ADDRESSABLE SUPP./ <br />VIGILANT SERIES GSA -SD <br />DUCT <br />S/R <br />RTN. SIDE DUCT DET. <br />WITH SD-T60 SAMPLING TUBES <br />MOUNTED <br />D <br />DUCT DETECTOR <br />VIGILANT SERIES GSA -SD <br />CEILING <br />® <br />REMOTE TEST SWITCH <br />WITH SD-TRM <br />MOUNT <br />C <br />ADDRESSABLE <br />VIGILANT SERIES <br />PROVIDE DRY <br />M <br />MONITOR MODULE <br />GSA-CT1 <br />ENCLOSURES <br />E <br />ADDRESSABLE DUAL <br />VIGILANT SERIES <br />PROVIDE DRY <br />® <br />2 <br />MONITOR MODULE <br />GSA-CT2 <br />ENCLOSURES <br />E <br />ADDRESSABLE <br />VIGILANT SERIES <br />PROVIDE DRY <br />C R <br />RELAY MODULE <br />GSA-CR <br />ENCLOSURES <br />E <br />a F <br />SPRINKLER <br />FURNISHED BY OTHERS <br />FIELD LOCATE <br />�--c <br />FLOW SWITCH <br />MONITORED BY NEW FACP <br />PER FLOOR PLANS <br />D <br />T <br />SPRINKLER <br />.FURNISHED BY OTHERS <br />FIELD LOCATE <br />TAMPER SWITCH <br />MONITORED BY NEW FRCP <br />PER FLOOR PLANS <br />D <br />WALL MOUNT <br />WHEELOCK EXCEDER LHS3 SERIES <br />82" AFF TO <br />HORN STROBE <br />(*) CANDELA RATING <br />BOTTOM OF LENS <br />C <br />CEILING MOUNT <br />WHEELOCK EXCEDER LHSC3 SERIES <br />CEILING <br />HORN STROBE <br />(*) CANDELA RATING <br />MOUNT <br />C <br />CLG. <br />WALL MOUNT W.P. <br />WHEELOCK ASWP-2475W-FR SERIES <br />82" AFF TO <br />o, <br />Wp <br />HORN STROBE <br />115 CANDELA RATING <br />BOTTOM OF LENS <br />WBB <br />WALL MOUNT W.P. <br />WHEELOCK ASWP-2475C-FR SERIES <br />82" AFF TO <br />WP CLG. <br />HORN STROBE <br />115 CANDELA RATING <br />BOTTOM OF LENS <br />WBB <br />CEILING MOUNT <br />WHEELOCK EXCEDER LSTC3 SERIES <br />CEILING <br />C <br />CLG. <br />STROBE <br />(*) CANDELA RATING <br />MOUNT <br />FIRE ALARM 120VAC <br />DITEK DTK-120HW SERIES <br />FIELD LOCATED <br />120 <br />CIRCUIT PROTECTOR <br />AT FACP/BPS <br />D <br />MFR. DENOTES BACKBOX FURNISHED BY MANUFACTURER <br />AFF DENOTES ABOVE FINISHED FLOOR <br />WBB DENOTES WEATHERPROOF BACKBOX <br />BACKBOXES <br />REQUIRED BY OTHERS <br />2-1 /8' 2-1 /8" 1-1 /2" <br />DEEP DEEP DEEP <br />4" SQ. 1-1 /2" BLANK SINGLE 4-1 1 /16" 4-1 1 /16" OCTAGON <br />EXT. RING PLATE GANG BOX SQ. BOX EXT. RING BOX <br />BACKBOX SCHEDULE <br />A - 4" <br />BOX <br />WITH SINGLE GANG RING <br />B - 4" <br />BOX <br />WITH ROUND RING OR OCTAGON BOX <br />C - 4" <br />BOX <br />2-1 /8" DEEP WITH SGPR <br />D - 4" <br />BOX <br />ADJACENT FLEX TO DEVICE <br />E - 4" <br />BOX <br />2 1/8" DEEP WITH EXTENSION BOX <br />GENERAL <br />NOTES <br />SYSTEM INSTALLATION IN ACCORDANCE WITH <br />6TH EDITION (2017) OF THE FLORIDA BUILDING CODE <br />FLORIDA SPECIFIC ADDITION OF NFPA 1, THE FIRE CODE (2015) <br />NATIONAL ELECTRIC CODE (2014 EDITION) NFPA 72 (2013 EDITION) <br />NATIONAL FIRE ALARM SIGNALING CODE - FLORIDA SPECIFIC EDITION OF NFPA 101 <br />NFPA 101 (2015 EDITION) <br />FLORIDA ADMINISTRATIVE CODE 61G15-32 <br />ALL OTHER CODES MANDATED BY THE LOCAL AUTHORITY HAVING JURISDICTION <br />1) FIRE ALARM SYSTEM WIRING:. <br />STYLE B (CLASS B) INITIATION DEVICE CKTS. <br />STYLE Y (CLASS B) NOTIFICATION APPLIANCE CKTS. <br />STYLE 4 (CLASS B) ADDRESSABLE SIGNALING LINE <br />2) LOCKBOX TO BE MOUNTED OUTSIDE OF THE BUILDING WITHIN 6' OF <br />PRIMARY ENTRANCE DOOR AND AT A HEIGHT NOT TO EXCEED 12' AFF <br />NOR BE LESS THAN 8' AFF TO BOTTOM OF BOX. <br />KEYBOX SHALL BE ZONED INDEPENDENTLY IF REQUIRED BY THE LOCAL AUTHORITY <br />FIRE ALARM SYSTEM BATTERY CALCULATION <br />VIGILANT SERIES VS1 -RD (FACP) <br />ITEM <br />QTY <br />DESCRIPTION <br />STANDBY <br />ALARM <br />STANDBY <br />ALARM <br />per unit <br />per unit <br />Total <br />Total <br />A 1 MASTER CONTROLLER <br />0.155 <br />0.204 <br />0.155 <br />0.204 <br />B 1 REMOTE ANNUCIATOR <br />0.036 <br />0.146 <br />0.036 <br />0.146 <br />C 18 ADDRESSABLE DEVICES <br />0.0005 <br />0.0005 <br />0.009 <br />0.009 <br />D 1 FULL LOAD NOTIFICATION <br />0.000 <br />3.750 <br />0.000 <br />3.750 <br />E 3 AUX. 24VDC RELAY <br />0.000 <br />0.015 <br />0.000 <br />0.045 <br />TOTAL DRAW AMPS <br />0.200 <br />4.154 <br />STANDBY FOR 24 HOURS AMPS <br />4.800 <br />ALARM FOR 5 MINUTES AMPS <br />.347 <br />TOTAL BATTERY IN AMPS REQUIRED <br />5.147 <br />X 1.2 FACTOR <br />6.177 <br />BATTERIES SUPPLIED 7.0 AMP HOUR <br />NOTIFICATION CIRCUITS FUSED AT 2.5 AMPS <br />VIGILANT SERIES MIRBPS6A (PCPs) <br />ITEM <br />QTY <br />DESCRIPTION <br />STANDBY <br />ALARM <br />STANDBY <br />ALARM <br />per unit <br />per unit <br />Total <br />Total <br />A 1 MASTER CONTROLLER <br />0.175 <br />0.270 <br />0.175 <br />0.270 <br />B NOTIFICATION CIRCUIT 1 <br />0.000 <br />1.022 <br />0.000 <br />1.022 <br />C 1 NOTIFICATION CIRCUIT 2 <br />0.000 <br />1.109 <br />0.000 <br />1.109 <br />p 1 NOTIFICATION CIRCUIT 3 <br />0.000 <br />1.511 <br />0.000 <br />1.511 <br />E 1 NOTIFICATION CIRCUIT 4 (SPARE) <br />0.000 <br />0.000 <br />0.000 <br />0.000 <br />TOTAL DRAW AMPS <br />0.175 <br />3.912 <br />STANDBY FOR 24 HOURS AMPS <br />4.200 <br />ALARM FOR 5 MINUTES AMPS <br />.326 <br />TOTAL BATTERY IN AMPS REQUIRED <br />4.526 <br />X 1.2 FACTOR <br />5.432 <br />BATTERIES SUPPLIED 7.0 AMP HOUR <br />NOTIFICATION CIRCUITS FUSED AT 3.0 AMPS <br />FIRE ALARM FUNCTIONAL MATRIX:Ld <br />Uj <br />cn <br />Of <br />U <br />CONTROL UNIT ANNUNCIATION <br />NOTIFICATION <br />SUPPLEMENTARY <br />o <br />r <br />Z <br />� <br />Z <br />J <br />m <br />N <br />Z <br />CD <br />O <br />� <br />~ <br />CD a- <br />a-cn <br />a. <br />� � <br />¢ <br />WO <br />�Q N <br />� cwn <br />cn N <br />N CD~ <br />O <br />In� <br />Z <br />W <br />J <br />7 <br />ZO <br />W <br />J <br />�] <br />� <br />' <br />Q <br />m ta_ i <br />J <br />CD <br />J Z <br />� Z <br />� Z <br />� Z <br />Q <br />� H <br />N <br />W O <br />W O <br />Q <br />Q <br />(/w? <br />C=? <br />N <br />N <br />N <br />W lJi <br />W I.Ji <br />wQ <br />c-3 � <br />c.) � <br />c.> � <br />U o <br />N <br />� LU <br />of <br />� Uj <br />W= Uj <br />Ld rr <br />c=n <br />Q Q <br />Q Q <br />Q Q <br />Q Z <br />� <br />cwi <br />MANUAL PULL STATION <br />X <br />X <br />X <br />X <br />P.E. STAMP <br />0) CIO <br />co <br />00 <br />CD <br />L <br />CD <br />FT 00 <br />O LO <br />LCJ "I, <br />co� <br />C3 <br />� I <br />00 <br />� CO � cr) O <br />s` <br />O <br />w r-I I w <br />a W <br />Q � c) <br />CYJ co O <br />I �4 <br />� W <br />� o <br />LO <br />\ <br />Q <br />H <br />O C <br />2 <br />w � <br />CO � <br />�D W � <br />O � q <br />O <br />U1 � <br />W � <br />� O <br />� q � <br />L� <br />� O <br />N � C4 <br />E- <br />O <br />E- <br />O <br />DRAWN BY: DQDD <br />APPROVED BY: <br />DATE: 11 /21 /19 <br />scA-E: AS INDICATED <br />PROJECT N0: <br />DEVICE LEGEND <br />BATTERY CALCS. <br />RISER DIAGRAM <br />SEAL <br />DATE <br />FA 1 <br />O LO <br />LCJ "I, <br />co� <br />C3 <br />� I <br />00 <br />� CO � cr) O <br />s` <br />O <br />w r-I I w <br />a W <br />Q � c) <br />CYJ co O <br />I �4 <br />� W <br />� o <br />LO <br />\ <br />Q <br />H <br />O C <br />2 <br />w � <br />CO � <br />�D W � <br />O � q <br />O <br />U1 � <br />W � <br />� O <br />� q � <br />L� <br />� O <br />N � C4 <br />E- <br />O <br />E- <br />O <br />DRAWN BY: DQDD <br />APPROVED BY: <br />DATE: 11 /21 /19 <br />scA-E: AS INDICATED <br />PROJECT N0: <br />DEVICE LEGEND <br />BATTERY CALCS. <br />RISER DIAGRAM <br />SEAL <br />DATE <br />FA 1 <br />Q <br />H <br />O C <br />2 <br />w � <br />CO � <br />�D W � <br />O � q <br />O <br />U1 � <br />W � <br />� O <br />� q � <br />L� <br />� O <br />N � C4 <br />E- <br />O <br />E- <br />O <br />DRAWN BY: DQDD <br />APPROVED BY: <br />DATE: 11 /21 /19 <br />scA-E: AS INDICATED <br />PROJECT N0: <br />DEVICE LEGEND <br />BATTERY CALCS. <br />RISER DIAGRAM <br />SEAL <br />DATE <br />FA 1 <br />DRAWN BY: DQDD <br />APPROVED BY: <br />DATE: 11 /21 /19 <br />scA-E: AS INDICATED <br />PROJECT N0: <br />DEVICE LEGEND <br />BATTERY CALCS. <br />RISER DIAGRAM <br />SEAL <br />DATE <br />FA 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.