Laserfiche WebLink
ABBREVIATIONS <br />AB or A.B. <br />Anchor Bolt <br />FIX or FXD <br />Fixed <br />PWDR or Pwd. <br />Powder Room <br />ABV or Abv. <br />Above <br />FLR or Fir. <br />Floor <br />RA or R/A or R.A. <br />Return Air <br />AC or A/C <br />Air -Conditioner <br />FLR SYS or Flr Sys <br />Floor System <br />RAD or Red. <br />Radius <br />ADJ orADJ. <br />Adjustable <br />FOM or F.O.M. <br />Face Of Masonry <br />RAG or Rag. <br />Return Air Grill <br />AFF or A.F.F. <br />Above Finished Floor <br />FP or F.P. <br />Fireplace <br />REC or Rec. <br />Recessed <br />AHU or A.H.U. <br />Air Handler Unit <br />FR DR <br />French Door <br />RECEPT <br />Receptacle <br />ALT or ALT. <br />Alternate <br />FRT <br />Front <br />REF or Ref. <br />Refrigerator <br />Be <br />Base Cabinet <br />FT or Ft <br />Foot/ Feet <br />REINF <br />Reinforcing <br />BF <br />Bifold Door <br />FTG or Ftg. <br />Footing <br />READ or Req'd. <br />Required <br />BK SH or Bk Sh <br />BookShelf <br />FXD GL <br />Fixed Glass <br />RM or Rm. <br />Room <br />BILK or BILK. <br />Block <br />GALV or Gaiv. <br />Galvanized <br />RND or Rnd. <br />Round <br />BLW or BLW. <br />Below <br />GC or G.C. <br />General Contractor <br />RO or R.O. <br />Rough Opening <br />BM or Bm. <br />Beam <br />GFI or G.F.I. <br />Ground Fault Interrupter <br />IRS, R/S, R/SH or R&S <br />Rod and Shelf <br />BOT or Bot. <br />Bottom <br />GT or G.T. <br />Girder Truss <br />SO or SD. <br />Smoke Detector <br />BP or B.P. <br />Bypass (door) <br />GYP BD or Gyp. Bd. <br />Gypsum Board <br />SGD <br />Sliding Glass Door <br />BRG or BRG. <br />Bearing <br />HB <br />Hose Bibb <br />SH or Sh. <br />Shelves <br />C <br />Carpet <br />HDR or Hdr. <br />Header <br />SHT <br />Sheet <br />CAB <br />Cabinet <br />HGT or Hgt. <br />Height <br />SHWR or Shwr. <br />Shower <br />CIR or Cir. <br />Circle <br />HH or H.H. <br />Hand Held (plumbing faucet) <br />SL or S.L. <br />Side Lights <br />CJ or C/J <br />Control Joint <br />HORIZ <br />Horizontal <br />SPECS or SPECS. <br />Specifications <br />CLG or Cig. <br />Ceiling <br />HS <br />Hard Surface (flooring) <br />SPF or S.P.F. <br />Spruce Pine Fir <br />CMU <br />Concrete Masonry Unit <br />ILO <br />In Lieu Of <br />SO FT or SF or S.F. <br />Square Foot (feet) <br />COFF or Coff. <br />Coffered or Tray Ceiling <br />INSUL or Insul. <br />Insulation <br />SO or Sq. <br />Square <br />COL or Col. <br />Column <br />INT or Int. <br />Interior <br />STO <br />Storage <br />COMM or Comm. <br />Community <br />K/WALL or KlWall <br />Kneewall <br />SW or S.W. <br />Shear Wall <br />COMP or Comp. <br />Compressor <br />KS or K.S. <br />Knee Space <br />SYP or S.Y.P. <br />Southern Yellow Pine <br />CONN or CONN. <br />Connection <br />LAUN or Laun. <br />Laundry <br />TB <br />Towel Bar <br />CONT or Cont. <br />Continuous <br />LAV or Lay. <br />Lavatory <br />TEMP or Temp. <br />Tempered <br />CT or C.T. <br />Ceramic Tile <br />LF or L.F. <br />Linear Ft. <br />THIKN or Thik'n. <br />Thicken <br />D or D. <br />Dryer <br />LL <br />Lintel Length <br />TOB or T.O.B. <br />Top of Block <br />DB <br />Door Bell <br />LT <br />Laundry Tub <br />TOM or T.O.M. <br />Top of Masonry <br />DBL or Dbl. <br />Double <br />MAS or Mas. <br />Masonry <br />TOP or T.O.P. <br />Top of Plate <br />DCF <br />Decorative Cementitious Finish <br />MAX or Max <br />Maximum <br />TP <br />Toilet Paper Holder <br />DEC or Dec. <br />Decorative <br />MC <br />Medicine Cabinet <br />TR <br />Towel Ring <br />DIED or Ded. <br />Dedicated (outlet) <br />MFR or Mfr. <br />Manufacturer <br />TRANS WDW or Trans. <br />Transom Window <br />DIA or Dia. <br />Diameter <br />MGT <br />Management (room) <br />TYP or Typ. <br />Typical <br />DISP or Disp. <br />Disposal <br />MIN or Min <br />Minimum <br />UC or u.c. <br />Under Counter <br />DIST or Dist. <br />Distance <br />MIR or Mir. <br />Mirror <br />UCL <br />Under Cabinet Lighting <br />DMF <br />Decorative Masonry Finish <br />ML or M.L. <br />Microlam <br />LINO or U.N.O. <br />Unless Noted Otherwise <br />DS or D.S. <br />Drawer Stack <br />MONO or Mono <br />Monolithic <br />V or v. <br />Valve (shower or tub/shower) <br />DTL <br />Detail <br />MW or MICRO or Micro. <br />Microwave <br />VB <br />Vanity Base <br />DV or D.V. <br />Dryer Vent <br />NTS or N.T.S. <br />Not to Scale <br />VERT or Vert. <br />Vertical <br />DVP or D.V.P. <br />Diverter Valve (plumbing) <br />OE or O.E. <br />Owner's Entry <br />VL or V.L. <br />Versalam <br />DW or D.W. <br />Dishwasher <br />OPNG or Opn'g. <br />Opening <br />VTR <br />Vent through Roof <br />EA or Ea. <br />Each <br />OPT or Opt <br />Optional <br />W or w <br />Washer <br />ELEC or Elec. <br />Electrical <br />PC <br />Pull Chain <br />W/ or w/ <br />With <br />ELEV or Elev. <br />Elevation <br />PED or Ped. <br />Pedestal <br />WA or WA. <br />Wedge Anchor <br />EQ <br />Equal <br />PH <br />Phone <br />WC or We or W.C. <br />Water Closet (toilet) <br />EW or E.W. <br />Each Way <br />PKT or Pkt. <br />Pocket (Door) <br />WD or Wd <br />Wood <br />EXP or Exp. <br />Expansion <br />PL or P.L. <br />Parallam <br />WOW HDR or WOW. HDR. <br />Window Header <br />EXT or Ext. <br />Exterior <br />PLF <br />Pounds per linear foot <br />WH or W.H. <br />Water Heater <br />FBC <br />Florida Budding Code <br />PLNT SHLF or Pit. Sh. <br />Plant Shelf <br />WIC or W.I.C. <br />Walk-in Closet <br />FDN or Fdn. <br />Foundation <br />PLT HT or Pit. Ht. <br />Plate Height <br />WM or W.M. <br />Wall Mounted (plumbing fixture) <br />FG <br />Fiberglass (Shower Pan) <br />PSF <br />Pounds per square foot <br />WP <br />Water Proofing) <br />FIN <br />Finished <br />PT or P.T. <br />Pressure Treated <br />WS <br />Water Softener <br />FIN FLR or FF or Fin. Flr. Finished Floor <br />PW or P.W. <br />Pre -wire <br />WWF <br />Welded Wire Fabric (Mesh) <br />PLAN REVISIONS <br />DATE VERSION DESCRIPTION <br />08-20-15 1.0 1.00EW EhUM BAW PLAN <br />12-8-15 2.0 FRAME -WALK REVISIONS <br />12-27-17 3.0 2017 FBC UPDATES <br />05-20-19 3.1 ELEV. Al -REVISED BANDS BACK TO <br />ORIGINAL DESIGN <br />a� <br />1551 <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />FLOOR PLAN <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAILS <br />4 <br />ELECTRICAL PLAN <br />5 <br />ROOF PLAN <br />6 <br />FOUNDATION PLAN MONO <br />7 <br />ROOF FRAMING PLAN <br />8 <br />LINTEL PLAN AND DETAILS <br />SIN <br />STRUCTURAL NOTES <br />SN1 <br />DETAILS <br />S3M <br />MONO DETAILS <br />S4 <br />DETAILS <br />S5 <br />DETAILS <br />SS <br />RETROFIT DETAILS <br />D1 <br />SECTIONS & DETAILS <br />WP <br />WATERPROOFING DETAILS <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />PA1.3 <br />PRODUCT APPROVAL NUMBERS <br />ALLIWORK SHALLm vnNG CODE, <br />THE <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />� 0 � <br />O <br />0 V <br />z_o <br />z� <br />z <br />a <br />to c <br />Cl <br />(1) <br />C <br />a-J w <br />�J — <br />w <br />c/h Of <br />t.n:D <br />N <br />LU <br />r0 � M <br />U f%j <br />o <br />L V- o <br />to <br />¢rn <br />Rv <br />rnQ o <br />B D� <br />NN C� <br />d <br />' N N <br />10 00 <br />Z' <br />.j <br />Z ri Z <br />W w <br />LU d ii a <br />go <br />Z 0 <br />LLZQ <br />W NavNi• A <br />%rRi1f911fl/U <br />OM <br />Ly <br />C't <br />�) <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />o <br />W G <br />�a <br />a <br />oQ o <br />22 z� <br />Q <br />w <br />O�LLo <br />V W <br />F <br />L <br />� <br />UJ <br />Z <br />w3 <br />X <br />L <br />Ln <br />> <br />O <br />o <br />0Zo <br />oS <br />J <br />z <br />W <br />� <br />Q <br />Z <br />Ln <br />..�� <br />J <br />W <br />Lll <br />tj <br />z <br />o <br />Cal <br />Z <br />= <br />UJ <br />.-+ <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 08/08/2019 <br />TECH: FM <br />VERSION NO. 3ol <br />SHEET NO. <br />C S <br />