<br /> ...�1 T�IIlIiTY�ERD
<br /> 3
<br /> .'APPEN�IX�I:ATTpCNMENYREQUIREMENTS,FOR-WINOUPLIFTRESISTANCE"„ , ",,, ,� � ` ,�
<br /> Ta61e Deck Appllcation Type Descrlptlon Page
<br /> lA Wood New,Reroof(Tear-Off�,Recover C MechanicallyAttached Insulation,Bonded Roof Cover 3
<br /> 18 Wood New Constructlon F Non-Insulated,Bonded Roof Cover 3
<br /> 2A Steel ar Conc. New,Reroof(Tear-Off�,Recover C Mechanically Attached Insulation,Bonded Roof Cover 4-6
<br /> 28-1 Steel or Conc. New,Reroof(Tear-Off�,Recover D Insulated,Mechanically Attached Roof Cover(Stress Plates� 7
<br /> 28-2 Steel or Conc. New,Reroof(Tear-Off�,Recover D Insulated,Mechanically Attached Roof Cover(8attens) 8
<br /> 3A Concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 9-10
<br /> 3B Concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded RoofCover 10
<br /> 4A Various Recover A-1 Bondedlnsulatfon,Donded RoofCover 11-12
<br /> The following notes apply to the systems outlined herein:
<br /> 1. 7he raof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. �oad resistance of the
<br /> roof deck shall he documented through proper codlfled and/or FBC Approval documentatlon.
<br /> 2. Unless otherwise noted,fasteners and stress plates for Insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
<br /> Y Wood Deck: Mule-Hide HDP Fastener with Mule-Hide 3 in.Insulatlon Plate,OMG#12 or#14 Roofgrip wlth Flat Bottom Plate,OMG#12 Standard or ti14 HD with OMG Standard metal plate,Dekfast ti12
<br /> or St14 with Hex Plate,Trufast DP or HD with Trufast 3"Metal Insula[ion Plate Plates. Minimum'/.-fnch plywood penetration,or 1-inch wood plank emhedment
<br />—�Ste�Deck: Mo�e=Hid€HDP-fastenerwith-Mule-Hide3-in.—Insulation-Plate�OMG-p12or�t14Boofgdpyvitl]Fla_tBottom Plate,OMG#12 Standard or tl14 HD with OMG Standard metal plate,Dekfast it12
<br /> or tt14 with Hex Plate,Trufast DP or HD with Trufast 3"Metal Insulation Plate Plates. Minimum'/.-inch steel penetration,engage the top flute of the stee ec .
<br /> ➢ Concrete Deck: Mule-Hide HDP Fastener or Mule-Hide CF with Mule-Hide 3 in.Insulatfon Plate,OMG ti14 Roofgrip with Flat Bottom Plate,OMG#14 HD or CD-10 with OMG Standard metal plate,Dekfast
<br /> 7114 or Dekspike with Hex Plate,Trufast HD or CF wi[h Trufast 3"Metal Insulation Plate Pla[es.Mlnimum 1-inch embedment. Fasteners installed with a pilo[hole in accordance with the
<br /> fastenermanufacturels published installatlon instructlons.
<br /> 3. Unless otherwise noted,insulation may he any one layer or combination of polyisocyanurate,polysryrene,wood fiberboard,perlite,Dens Deck,Dens Deck Prlme,SECUROCK Gypsuin-Fiber Roof Board or SECUROCK
<br /> Glass-Mat Roof Board that meets the OA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC 26o3,4.1 or 2603.6,when installed wfth the roof cover
<br /> 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be suhstituted for rigid insula[ion board for System Type D�mechanically attached membrane),wherehy the membrane fasteners are
<br /> installed through the LWIC to engage tlie structural steel or concrete deck.The structural deck shall be of equal or greater configuration to the steel and concrete deck Iistings.
<br /> 5. Preliminary insulation a[tachment for Sys[em Type D=Minimum four fasteners per 4 x B ft hoard or minimum[wo fasteners per 4 x 4 ft 6oard.
<br /> 6. Unless otherwise noted,Insulation adhesive application retes are as follows. Ribbon or bead width(s ax the time of application;the ribbons/beads shall expand as noted In the manufacturer's published instrudlons:
<br /> D Hot Asphalt: Applied at a rate af 20-40 Ibs./sq.
<br /> D OlyBond 500: Continuous'/.to 1-inch wide ribbons,12-inch o.c.using PaceCart or SpotShot application devices.
<br /> ➢ lVofe: When multiple layers(sJ of insulatian and/or cover6oard ore/nstaded in ribbon-oppl(ed odhesive,adhesive rib6ons sha!/6e sYaggered from layer-[o-layer a distance of one-half Lhe ribGon spacing.
<br /> D Note:The maximum edge distonce from the adhesive ri6ban[o fhe edge of[he insulation board shall be naf less[han one-half the specffied ribbons spacing
<br /> Exterlor Research and Design,LLC.d/b/a Trinity�ERb Evaluation Report M31240.11.09-RS for FL10703-R6
<br /> Certificate of Authorization N9503 Revislon 5:03/20/2015
<br /> Prepared by: Robert Niemtnen,PE-59166 Appendix 1,Page 1 of 12