My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16496
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16496
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2016 9:37:16 AM
Creation date
3/7/2016 9:37:15 AM
Metadata
Fields
Template:
Building Department
Company Name
MOORES FIRST ADDITION
Building Department - Doc Type
Permit
Permit #
15-16496
Building Department - Name
COSTON II,JOEL & ALMA
Address
38831 B AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r-�.< <br /> � ;� � <br /> ��`������I��ERD ' <br /> - t <br /> 7 lJnless othenuise noted,all insulations are Flat slock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limita[ions may be substituted with the following Maximum <br /> �esign Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that Ifsted for a particular system in the tables,then <br /> the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the[able: <br /> ➢ OlyBond 500: MDP -187.5 psf (Min.0.5-inch thick� <br /> S. Bonded polyisocyanurate insulation boards shall be maxlmum 4 x 4 ft. <br /> 9. For mechanically attached components or partially 6onded insulation,[he maximum design pressure for the selected assem6ly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC <br /> Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professlonal to resist the elevated pressure criteria. Commonly used methods are RAS 117,FM LPDS 1-29 and <br /> ANSI/SPRI WDl. Assemblies marked with an asterisk'carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for 2one 2/3 enhancements. <br /> 10. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no <br /> retional analysis is permitted. <br /> 11. For mechanically a[tached components over existing decks,fasteners shall he tested in the existiny deck for withdrawal resistance. A qualified desi�n professional shall review[he data for comparison to the <br /> minfmum requirements for the system.Testing shall be in accordance with TAS 105 or ANSI/SPRI FX-1. <br /> 12. For existing substrates in a bonded recover or re-roof(nstallatlon,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing <br /> roof system(for recover}shali be capable of reststing project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1-52, <br /> ANSI/SPRI IA-1 or TAS 124. <br /> 13. For System Type D,steel deck appllcations,the roof inem6rane shall be run with Its length perpendicular to the steel deck flutes. <br /> 14. For Recover Applications using System Type D,the Insulation is optlonal.Alternatively,min.0.25-Inch to 0.625-Inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof <br /> 8oard may he used as a separetor board,preliminarily attached prior to roof cover ins[alla[ion.The existing roof system shall be suitahle for a recover applica[ion. <br /> �5._For membrane attachment using batten-strips,end laps shall 6e spliced with sufficient dimension to allow for minimum 2-fasteners at each batten-strip lap. <br /> 16. Side laps shall be sealed in ac[ordance with Mule-Hide requirements: <br /> ➢ Primed with Mule-Hide Tape Primer and adhered with Mule-Hide In-Seam 7ape <br /> ➢ Cleaned wtth Mule-Hlde Splice Cleaner and adhered with Mule-Hide Black or White Splice Adhesive. . <br /> 17 Membrane adhesive applica[ion rates are as follows: <br /> ➢ Mule-Hide Bonding Adhesive in a contact application at combined rete of 60 ft'/gal. <br /> ➢ WBBA 2000 in a contact application at a combined rate of 50 to 60 ft'/gal. <br /> ➢ Mule-Hide Acrylic Water Base Bonding Adhesive in a su6strate application at rete of S00 ft1/gal. <br /> 18. "MDP"=Mazimum Design Pressure is[he result of[esting for wind load resistance based on allowa6le wind loads. Refer to FBC 1609 for determination of design wind loads. <br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report fv131240.11.09-RS for FL10703-R6 <br /> Certificate of Authorization fF9503 Revislon 5:03/20/2015 <br /> Prepared by: Robert Niemfnen,PE-59166 Appendix 1,Page 2 of 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.