Laserfiche WebLink
1 � <br /> APPROVED ASSEMBLIES: <br /> Deck Type 1: Wood,Non-insulated <br /> Deck Description: 19/32" or greater plywood or wood plank <br /> System E(1): Anchor sheet mechanically fastened'to deck,membrane adhered. <br /> Base Sheet: One or more plies of ASTM D 226 Type 1I or ASTM D 2626 with a.minimum 4" <br /> side lap and a 6"end lap mechanically fastened to deck with approved annular <br /> ringshank nails and tin caps 6" o,c, at the laps and two staggered rows 12" o.c.the <br /> field of the roll. <br /> Mem6rane: One or more plies of TW Metal and Ti�e Undexlayment with a minimum 4"side <br /> lap and 6"end Iap.Place the first course of inembrane parallel to the eave,rolling <br /> the membrana to obtain maxim:um contact,Remove the release liner ss the <br /> membrane is applied. Vertical strapping of the roof with TW Metal and Tile <br /> Underlayment is acceptable. <br /> When used in Tile roof systems#he capsheet shall be back naiied to deck with <br /> approved annular ring shank nails and tin caps at a maximum l2"o.c. at th�side <br /> laps and 6" o,c,a#the end laps. No nails or tin caps shaIl be exposed. <br /> Surfacing: Approved Mechanically Fastened Tile or Metal Roofing Assembly or App�oved <br /> Roofing Assemblies where an ASTM D 1970 underlayment is allowed. <br /> Deck Type 1: Wood,Non-insulated <br /> Deck Descriptfon: 19/32" or greater plywood or wood plank <br /> System E(2): Anchor sheet mechanically fastened to deck,membrane adhered. <br /> Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimuim 4" <br /> side lap and a 6"end lap mechanically fastaned to deck with approved annular <br /> ringshank nails and tin caps 6"o.c, at the laps and two staggered rows 12"o.c,the <br /> �eld of the rolt. <br /> Membrane: One or more plies of Moisture Guard Plus with a minimum 3,5"side!ap and 6" <br /> end lap. Place the�rst course of inembrane pazallel to the eave,roIling the <br /> membrane to obtain maximum contact. Remove the release liner as the mexnbxane <br /> is applied. Vertical strapping of tha roof with Moistare Guard Plus is acceptable. <br /> Surfacing: Approved Roofing Assemblies where an ASTM D ]970 underlayment is allowe�l. <br /> Deck Type 1: Wood,Non-insulated <br /> Deck Descrlptlou: t9/3Z" or greater plywood or wood plank <br /> System E(3): Anchor sheet mechanically fastened to deck,membrane adhered. <br /> Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" <br /> side lap and a 6"and iap mechanically fastened to deck with approved annalar <br /> ringshank nails and tin caps 6" o.c.at the taps arid two sta�gered rows 12" o.c.the <br /> field of the roll. ' <br /> Membrane: One or more plies�of TW Undtex'�"'��meat with a minimum 4"side lap and 4"end <br /> lap.Placa the first course of inembrane parallel to the eave,rolling the membrane <br /> to obtain maximum contact. Remove the release liner as the membxane is applied, <br /> Vertical strapping of the roof with TW Undarlayment is aoceptable. <br /> Surfac�ng: Approved Roo#ing Assemblies where an ASTM D 197Q underlayment is a�lowed. <br /> NOA No.: 12-0406.07 <br /> Expiration Date: d7/05/17 <br /> M� , . � NTM Approval Date: 06/21/12 <br /> Pa�e 4 of 6 <br />