Permit #
15-16312
Building Department - Name
MCCOY,FERN C
Address
5123 21ST ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� , ; • '� <br /> Deck Ty�e 1s Wood,Non-insulated <br /> Deck Desc�riiption: 19/32" or greater plywood or wood plank <br /> System E(4): Anchor sheet mechanicaIly fastened to deck,meznbrane adhered, , � 'I <br /> Base Sheet: One or more piies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" <br /> side lap and a 6"end lap mechantcally fastened to deck with approved annular <br /> ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12"o.c.the <br /> field of the roll, <br /> Membrane: One or more plies of Awaflex,Awaplan 170 or Awa�lan Premium applied at a <br /> right angle(90°)to the slope of the deck adhered in a fuil mopping of approved <br /> asphalt applied within the EVT range and at a rate of 20-401bs,/sq. Vertical <br /> strapping of the roof with Awaflex,Awaplan 170 or Awaplan Premium <br /> underlayments is accaptable. <br /> When usad in Tile roof systems the capsheet shall be back nailed to deck with <br /> approved annular ring shank nails and tin caps at a maximum 12"o.c, at the side <br /> laps and 6"o,c. at the end laps. No nails or tin caps shalI ba axposed, • <br /> Surfacing: Approved Mechanically Fastened or Adhered Tile or Metal Roofing Assembly or <br /> Approved Roofing Assamblles where an TAS 104 underlayment is allow�d. <br /> Deck Type �: Wood,Non-insulated <br /> Deck Description: 19I32}� or greater plywood or wood plank <br /> System E(S): Anchor sheet mechanically fastened to deck,membrane adhered. <br /> Base Sbeet: One or more pl'ses of Tamko SA Base with a minimum 4"side lap and a 6"end <br /> lap mechanically fastened to deck with approved annular ringshank nails and tin <br /> caps 6" o.c.at the laps and two staggered rows 12" o.c. the field of the roll.Shall <br /> oniy be mechanically fastened to woad deck.Direct adhesion to wood deck <br /> uot permitted in the HVHZ.Do Not Remove Release Film1 <br /> Membrane: One or mote plies of Tamko SA Cap with a minimum 4"side lap and 6"end lap, <br /> Place the first coarse of inembrane paralle!to the eave,rolling the membr�ne to <br /> obtain maximum contact with base sheet,Remove the release liner as the <br /> mambrane is applied,Vertical strapping of the roof with Tamko SA Cap • <br /> underiayment is acceptabie. <br /> When used in Tile roof systems the capsheet shall be back nailed to deck with <br /> approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side <br /> laps and 6" o.c. at the end laps. No nails or tin caps shail be exposed <br /> Surfacing: Approved Mechanically Fastened Tile or Metal Roofing Assembly or Ap��roved <br /> Roofing Assamblies where an ASTM D 6164 membraae is allowed. <br />� <br />�i <br /> NOA No.: 1�0406,07 <br /> AM�N,r,Y Expiration Date: 07/05/17 <br />� ,, � � Approval Date: 06/21/12 <br /> Pa�ge 5 of 6 <br />