Laserfiche WebLink
��� <br /> �� ��I�O��ERD <br /> � <br /> TABLE 2A: STEEL oa CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TeAR-OFF)oR RECOVER <br /> SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER <br /> System Deck Top Insulation Layer Roof Cover/Adhesive MDP <br /> Base Insulation Layer Fasteners Attach (Psfl <br /> No. (See Note 1) Type <br /> Mule-Hide Standard Black EPDM, <br /> Min.22 ga.,type B, Mule-Hide HDP Fastener or White-on-Black EPDM,Standard <br /> Mule-Hide CF(concrete 1 per 1.6 <br /> SC-7 Grade 33 steel or Min.1.5-inch Approved Reinforced EPDM or FR Reinforced -75.0 <br /> Min.0.5-inch SECUROCK Gypsum-Fiber Roof Board on/y)with Mule-Hide 3 in, ft2 <br /> min.2,500 psi polyisocyanurete EPDM/Mule-Hide Bonding <br /> concrete Insulation Plate Adhesive <br /> Min.0.5-inch Dens Deck,Dens Mule-Hide HDP Fastener or <br /> Min.22 ga.,type B, Deck Prime or SECUROCK Mule-Hide Standard Reinforced <br /> SC-8 Grede 33 steel or Gypsum-Fiber Roof Board, Min.0.5-inch Dens Deck,Dens Deck Prime or Mule-Hide CF(concrete 1 per 1 EPDM or FR Reinforced EPDM/ -97•5 <br /> min.2,500 psi followed by min.1.5-inch SECUROCK Gypsum-Fiber Roof Board onlyJ with Mule-Hide 3 in. ft2 Mule-Hide Bonding Adhesive <br /> concrete Insulation Plate <br /> SIYROFOAM DECKMATE Plus FA <br /> Min.22 ga.,type B, Mule-Hide HDP Fastener or Mule-Hide Standard Reinforced <br /> SC-9 Grade 33 steel or Min.1.5-inch Approved Min.0.5-inch Dens Deck,Dens Deck Prime or Mule-Hide CF(concrete 1 per 1 EPDM or FR Reinforced EPDM/ -97•5 <br /> min.2,500 psi polyisocyanurete SECUROCK Gypsum-Fiber Roof Board only)with Mule-Hide 3 in. ft� Mule-Hide Bonding Adhesive <br /> concrete Insulation Plate <br /> MEMBRANE APPLIED IN WBBA 2000 ADHESIVE: <br /> Min.22 ga.,type B, Mule-Hide HDP Fastener or Mule-Hide Standard Black EPDM, <br /> SC-10 Grede 33 steel or (Optional)One or more layers, Min.0.5-inch HP Recovery Board or min.0.25-inch Mule-Hide CF(concrete 1 per 4 Standard Reinforced EPDM or FR -30.0" <br /> min.2,500 psi any combination,loose laid Dens Deck Prime onlyJ with Mule-Hide 3 in. ft� Reinforced EPDM/WBBA 2000 <br /> concrete Insulation Plate <br /> Min.22 ga.,type B, Mule-Hide HDP Fastener or Mule-Hide Standard Black EPDM, <br /> Grade 33 steel or Mule-Hide CF(concrete 1 per 2 Standard Reinforced EPDM or FR -37.5* <br /> SC-11 None Min.0.5-inch HP Recovery Board only)with Mule-Hide 3 in. ft� <br /> min.2,500 psi Reinforced EPDM/WBBA 2000 <br /> concrete Insulation Plate <br /> Min.22 ga.,type B, Min.1.5-inch Poly I50 2, Mule-Hide HDP Fastener or Mule-Hide Standard Black EPDM, <br /> Grade 33 steel or ACFoam II,Polyiso HP-H,HP-N, Mule-Hide CF(concrete 1 per 2 Standard Reinforced EPDM or FR -45.0" <br /> SC-12 min.2,500 psi HP-W,Poly ISO 1,H-Shield, Min.0.5-inch HP Recovery Board only)with Mule-Hide 3 in. ftZ <br /> Reinforced EPDM/WBBA 2000 <br /> concrete ENRGY 3 Insulation Plate <br /> Min.22 ga.,type B, Min.1.5-inch Poly ISO 2,ACFoam II,Polyiso HP-H, Mule-Hide HDP Fastener or Mule-Hide Standard Black EPDM, <br /> SC-13 Grede 33 steel or (Optional)One or more layers, HP-N,HP-W,Poly ISO 1,H-Shield,ENRGY 3,min. Mule-Hide CF(concrete 1 per Z Standard Reinforced EPDM or FR -45.0` <br /> min.2,500 psi any combination,loose laid 7/16"APA Rated oriented strand board or min. only)with Mule-Hide 3 in. ftz Reinforced EPDM/WBBA 2000 <br /> concrete 0.25-inch Dens Deck Prime Insulation Plate <br /> MEMBRANE APPLIED IN MULE-HIDE ACRYLIC WATER BASE BONDING ADHFSIVE: � <br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report M31240.11.09-R4 for FL10703-RS <br /> Revision 4.12/19/2014 <br /> Certificate of Authorization#9503 <br /> y Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 5 of 12 <br />