<br /> TABLE 2A: STEEL oa CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TenR-OFF)oa RECOVER
<br /> SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
<br /> System Deck Top Insulation Layer Roof Cover Adhesive MDP
<br /> Base Insulation Layer � (psf)
<br /> No. (See Note 1) Type Fasteners Attach
<br /> MEMBRANE APPLIED IN MULE-HIDE BONDING ADHESIVE: ,
<br /> Min.0.5-inch thick HP Recovery Board,Fiber Base
<br /> HD1,GP High Density Roof Fiberboard,min.0.25- Mule-Hide Standard Black EPDM,
<br /> Min.22 ga.,type B, inch thick Dens Deck,Dens Deck Prime or White-on-Black EPDM,Standard
<br /> Grede 33 steel or (Optional)One or more layers, 1 per 2
<br /> SC-1 min.2,500 psi any combination,loose laid SECUROCK Gypsum-Fiber Roof Board,min.1.5-inch See Note 2 ft� Reinforced EPDM or FR Reinforced -45.0*
<br /> Poly ISO 2,ACFoam II,ACFoam III,Polyiso HP-H,HP- EPDM/Mule-Hide Bonding
<br /> concrete N,HP-W,Poly ISO 1,H-Shield,H-Shield CG,ENRGY Adhesive
<br /> 3,PSI-25,Multi-Max FA-3
<br /> Mule-Hide Standard Black EPDM,
<br /> Min.22 ga.,type B, Min.1.5-inch Poly ISO 2 WF,ACFoam White-on-Black EPDM,Standard
<br /> Grade 33 steel or (Optional)One or more layers, 1 per 3 .
<br /> SC-2 min.2,500 psi any combination,loose laid Composite/FB,Polyiso HP-H Composite,H-Shield- See Note 2 ftz Reinforced EPDM or FR Reinforced -45.0
<br /> WF,ENRGY 3 Plus EPDM/Mule-Hide Bonding
<br /> concrete
<br /> Adhesive
<br /> Mule-Hide Standard Black EPDM,
<br /> Min.22 ga.,type B, Min.2.0-inch Poly ISO 2,ACFoam II,ACFoam III, White-on-Black EPDM,Standard
<br /> Grede 33 steel or (Optional)One or more layers, 1 per 4
<br /> SC-3 min.2,500 psi any combination,loose laid Polyiso HP-H,HP-N,HP-W,Poly ISO 1,H-Shield,H- See Note 2 ftZ Reinforced EPDM or FR Reinfor�ed -45.0*
<br /> Shield CG,ENRGY 3,P51-25,Multi-Max FA-3 EPDM/Mule-Hide Bonding
<br /> concrete Adhesive
<br /> Min.0.5-inch Dens Deck,Dens
<br /> Min.22 ga.,type B, Mule-Hide HDP Fastener or
<br /> Deck Prime or SECUROCK Mule-Hide Standard Reinforced
<br /> SC-4 Grade 33 steel or Gypsum-Fiber Roof Board, Min.0.5-inch Dens Deck,Dens Deck Prime or Mule-Hide CF(concrete 1 pe Z13 EPDM or FR Reinforced EPDM/ -67.5
<br /> min.2,500 psi followed by min.1.5-inch SECUROCK Gypsum-Fiber Roof Board onlyJ with Mule-Hide 3 in. ft Mule-Hide Bonding Adhesive
<br /> concrete STYROFOAM DECKMATE Plus FA Insulation Plate
<br /> Min.22 ga.,type B, Mule-Hide HDP fastener or Mule-Hide Standard Reinforced
<br /> Grede 33 steel or Min.1.5-inch Approved Min.0.5-inch Dens Deck,Dens Deck Prime or Mule-Hide CF(concrete 1 per 1.3 EPDM or FR Reinforced EPDM/ -67.5
<br /> SC-5 min.2,500 psi polyisocyanurate SECUROCK Gypsum-Fiber Roof Board onlyJ with Mule-Hide 3 in. ft� Mule-Hide Bonding Adhesive
<br /> concrete Insulation Plate
<br /> Min.22 ga.,type B, Mule-Hide HDP Fastener or Mule-Hide Standard Black EPDM,
<br /> Grede 33 steel or (Optional)One or more layers, Min.2.0-inch Poly ISO 2,ACFoam II,Polyiso HP-H, Mule-Hide CF(concrete 1 per 1.6 White-on-Black EPDM,Standard
<br /> SC-6 min.2,500 psi any combination,loose laid HP-N,HP-W,Poly ISO 1,H-Shield or ENRGY 3. onlyJ with Mule-Hide 3 in. ft� Reinforced EPDM or FR Reinforced -75.0
<br /> concrete Insulation Plate EPDM/Mule-Hide Bonding
<br /> Adhesive
<br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report M31240.11.09-R4 for FL10703-RS
<br /> Certificate of Authorization#9503 Revision 4:12/19/2014
<br /> � Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 12