Laserfiche WebLink
i <br /> • �. <br /> i <br /> SILENT j Addressable Devices <br />! . KNIGHT i with SK Protocol <br /> � � <br /> � by Honeywell � <br /> - � <br /> Addressable Devices with SK Protocol sK-HEAT-ROR , <br /> SK Module devices are intelligent addressable devices for use� A fixed temperature and rate-of-rise thermal detector that <br /> - with the following IntelliKnight addressable fire alarm control uses a thermistor sensing circuit to produce 135°F <br /> panels(FACPs): 5820XL,5808,and 5700. ; (57°C)thermal protection. Rate-of-rise detection occurs <br /> SK detectors, modules,and accessories communicate to the � at 15°F per minute(9°C per minute). Base included. <br /> FACP over the signaling line circuit loop(SLC loop)using a two- SK-BEAM <br /> wire connection.Shielded or twisted wire is not required. Up to� A beam smoke detector that is <br /> 99 addressable SK detectors and 99 SK modules can i' uniquely suited for protecting � <br /> communicate with the FACP on a single SLC loop.Any i open areas with high ceilings <br /> combination of addressable SK devices and SK modules can be " •; , <br /> used on a single SLC loop. i where other methods of smoke ',,? .,: <br /> detection are difficult to install ��'°'`�= <br /> The assortment of SK detectors, modules, and accessories that and maintain. <br /> are compatible with IntelliKnight addressable FACPs are SK-BEAM and <br /> described below. For detailed information on SK devices, see I SK-BEAM-T SK-BEAM-T <br />� the device specification sheet. A beam smoke detector that <br /> includes an integrated sensitivity test feature.The SK- <br /> Detectors i BEAM-T is uniquely suited for protecting open areas with <br />' SK-PHOTO � high ceilings where other methods of smoke detection <br />' A plug-in photoelectric smoke detector. . are difficult to install and maintain. <br /> SK-PHOTO offers a unique optical :"��,'�� SK-DUCT ^�* ��_.• , <br /> sensing chamber that is engineered to , �' An Intelligent photoelectric air `� � '�`' <br /> sense smoke produced by a wide ���;��, � duct smoke detector used with %�;.` <br /> range of combustion sources.6"base 4-. �-- SK-PHOTO(included)provides <br /> included. early detection of smoke in air - ° : 'a - <br /> SK-PHOTO-T SK-PHOTO (base Included) moving through HVAC ducts. SK- � - �-` � '�� <br /> A plug-in photoelectric smoke detector with thermal. � DUCT housing contains a vacant SK-DUCT <br /> SK-PHOTO-T offers a unique optical sensing chamber that is ' mount for SK-RELAY(sold <br /> engineered to sense smoke produced by a wide range of separately).The SK-DUCT requires communication line <br /> power only. <br /> combustion sources. Dual electronic thermistors add 135°F � <br /> (57°C)thermal technology to maximize detection. Base I SK-ACCLIMATE <br />' included. � Incorporates both thermal and photoelectric technologies <br /> � that interact to maximize detection.The - <br /> SK ACCLIMATE <br /> SK-ION � has an on-board microprocessor with advanced software <br /> A plug-in ionization smoke detector.SK-ION incorporates a � that focuses on rejecting nuisance alarms. Base <br /> unique single source, dual chamber design to respond quickly to included. <br /> a broad range of fires. 6"base included i �� <br /> � SK-FIRE- .�"�'�,' <br /> CO <br /> .�. <br />� . .ti` <br /> S K-H EAT � <br /> The SK-FIRE-CO is a plug-in, � �,5���:��`��= �� <br /> A fixed temperature thermal detector addressable device that provides <br /> that uses a thermistor sensing circuit both fire and carbon monoxide , f � <br /> to produce 135°F(57°C)fixed " _ (CO)detection.The SK-FIRE-CO <br /> thermal detection. Base included. ..� r~` should be used in conjunction with <br /> the 6200S intelligent sounder base. SK-FIRE-CO <br /> SK-HEAT-HT SK-HEAT(base included) Modules <br /> A variable high temperature ! <br /> detector that provides high temperature detection at 135°F— SK-MONITOR <br /> 190°F(57°C—88°C). Base included. I A monitor module that acts as an interFace to contact <br /> devices,such as waterflow switches and pull stations. <br /> i The SK-MONITOR supports Class B supervised or Class <br /> A supervised wiring. <br /> i <br /> I <br /> � <br />