My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16510
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16510
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2016 8:37:13 AM
Creation date
6/15/2016 8:36:03 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
15-16510
Building Department - Name
MOSS,S ARDELL
Address
38444 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> SK-MINIMON This means you can retrofit an existing building and use existing <br /> ' A compact and light weight monitor module that acts as an conventional devices.The SK-ZONE supports Style B and Style <br /> interface to contact devices,such as waterFlow switches and D wiring. <br /> pull stations.The SK-MINIMON supports Class B supervised SK-ZONE-6 <br /> . wiring. <br /> SK-MONITOR-2 A two-wire interface module that has six integrated modules and <br /> A monitor module with two initiating circuits that acts as an allows an FACP to interface with and monitor two-wire <br /> conventional smoke detectors.This means you can retrofit an <br /> interFace to contact devices, such as waterflow switches and existing building and use existing conventional devices.The SK- <br />'I pull stations. Because the SK-MONITOR-2 is capable of ZONE-6 supports Class B and Class A wiring. <br /> monitoring two separate Class B circuits, it is ideal for , <br /> waterFlow tamper switch and flow switch monitoring. SK-ISO <br /> A line isolator module that acts as an <br /> SK-MON-10 automatic switch that opens when the line <br /> �10 point monitor module that acts as an interface to voltage on the SLC loop drops below four <br /> contact devices,such as waterflow switches and pull volts. Isolator modules are spaced between ' <br /> stations. Conventional 4-wire smoke detectors can be groups of sensors or modules in a loop to <br /> monitored for alarm and trouble conditions.The SK- protect the rest of the loop. If a short occurs ` 6 � <br /> MONITOR-10 supports ten Class B or five Class A �-- --- <br /> between any two isolators,then both SK-ISO <br />' supervised contact inputs. isolators immediately switch to an open <br /> SK-RELAY circuit state and isolate the devices between them. <br /> A relay module that allows an FACP to switch discrete ' <br /> contacts by code command.The relay contains two isolated Accessories <br /> sets of Form C contacts,which operate as a DPDT switch. SK-PULL-SA/SK-PULL-DA <br /> SK-RELAY-6 The SK-PULL-SA is a single action pull station requiring only <br /> A relay module that has six Form C relays.The SK-RELAY 6 one motion to activate the station.The SK-PULL-DA is a dual <br /> allows an FACP to switch discrete contacts by code action pull station requiring two motions to active the station. i <br /> command and can be used by virtually any normally open or 8501 /B210LP �i <br /> normally closed application. THe B501 is a 4"mounting base. B201 LP is a 6"mounting ' <br /> SK-RELAYMON-2 base. Both have built-in remote annunciator connections. <br /> The SK-RELAYMON-2 combines two relay outputs and two B200SR — <br /> monitor inputs into one module device. The module is TFie 6200SR is designed for new and `� <br /> capable of Class B supervised wiring to the monitored existing dwelling unit applications. It offers �'��F`� i I <br /> devices. It also contains Form C relay contacts allowing the maximum flexibility in installation, �=�`.�.'-.�• ' <br /> panel to switch the contacts on command. configuration,and operation to meet or r <br /> SK-CONTROL-6 � ------� exceed UL 268 and UL 464 requirements. BZOOSR Sounder <br /> �m� j ' Base <br /> A notification module that has six B200S <br /> integrated modules for maximum The sounder base"listens in"to the communication between the <br /> flexibility,allowing you to add attached sensor head and the fire alarm control panel (FACP)to <br /> notification circuits wherever they are adopt the same address as the detector, but as a unique device <br /> needed on an FACP SLC loop.The type on the loop.The B200S has support for CO detection <br /> SK-CONTROL-6 provides supervised SK-CONTROL-6 <br /> using the SK-FIRE-CO. <br /> monitoring of wiring to load devices that require an external ! <br /> power supply or amplifier to operate,such as bells, horns, B224RB <br /> and strobes.The SK-CONTROL-6 supports Class B and A 6"mounting base with a built-in Form C relay contact. Lets <br /> Class A wiring and has a short circuit protection monitor for yo'u control a wide variety of normally open and normally closed <br /> each module to protect external power supplies against short applications.The 6224RB supports Class B and Class A wiring. <br /> circuit conditions on the NAC. g224g� <br /> SK-CONTROL A 6"mounting base with a built-in isolator for SK-series <br /> A notification module that lets you add notification circuits detectors.The B224B1 prevents an entire communication loop <br /> wherever they are needed on an FACP SLC Ioop.The SK- from being disabled when a short circuit occurs by isolating any <br /> CONTROL provides supervised monitoring of wiring to load part of a loop that has a short from the rest of the loop. <br /> devices such as bells, horns,and strobes. Restores the entire loop when the cause of the short circuit is <br /> SK-ZONE corrected.Supports Class B and Class A wiring. <br /> i <br /> A two-wire interface module that allows an FACP to interface <br /> with and monitor two-wire conventional smoke detectors. I <br /> I <br /> � SILENT This document is not intended to be used for installation purposes.We try to <br /> keep our product information up-to-date and accurate.We cannot cover all <br /> KNIGHT specific applications or anticipate all requirements.All specifications are subject PN 53623 Rev D <br /> by Honeywell to change without notice.For more information!contact Silent Knight 12 O 2013 Honeywell Intemational Inc. <br /> Clintonville Road,Northford,CT 06472-1610.Fhone:(800)328-0103, <br /> Fax:(203)484-7118.For Technical Support,Please call 800-446-6444. <br />, wwwsilentknight.com ' <br /> i <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.