Laserfiche WebLink
G310A-A „ <br /> Page 6 Revised February 20, 2007 <br />� <br /> SENSOR ASSEMBLY crnv G3os� <br /> The sensor assembly,which is temperature activated, consists of two(2)metal housed detector assemblies with two <br /> (2) different wire lengths. Sensor one (1) is 30" long (P/N G305-1) sensor two (2) is 54" long (P/N G305-2). (See <br /> FIGURE 4) <br /> Temperature <br /> Temperature Sensor <br /> Sensor (P!N G305-2) <br /> (P!�G305-1) � <br /> � �� <br /> L <br /> ��. Tee (P!N G304-E) <br /> (P(N G304-D) <br /> � <br /> 1 <br /> � Quick Cannect DisVibution Assy. ____ <br /> Nozzle(FM G304-F) <br /> FIGURE 4 <br /> :DISTRI��JTION 1�SSEMBLY crnv csoa_A> <br /> The distribution assembly consist of two (2) Teflon lined N���� <br /> stainless steel braided hoses and two (2) ma�neric based Magnetic base with tee assembly shall be on <br /> adjustable nozzle assemblies. The hose assembly from the the same Slde of the range hood 8S the <br /> extinguisher has a length�ariation of 22"-30". In addition, system encfosure, i.e., if the magnetic base <br /> the hose assemb]y between the nozzles ranges in length with "T" is installed on the left side of the <br /> from 27"-36". range hood, enclosure shall be mounted <br /> inside the cabinetry above the range hood on <br /> The assembly is inscalled on the underside of the range the far leff side or vice versa for the right <br /> hood connecting to the hose from the cylinder extending side. (See FIGURE 4) <br /> through the 7/8"hole via the qwck connect fittmg to the <br /> tee. One magnetic base nozzle assembly is placed on each <br /> under portion of the range hood,left and right. <br />' — <br />