My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16527
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16527
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2016 8:49:08 AM
Creation date
6/15/2016 8:49:06 AM
Metadata
Fields
Template:
Building Department
Company Name
ADVENTIST HEALTH SYSTEM SUNBELT
Building Department - Doc Type
Permit
Permit #
15-16527
Building Department - Name
ADVENTIST HEALTH SYSTEM SUNBELT
Address
7340 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- <br /> G310A-A <br /> • Revised February 20, 2007 j - Page 7 <br /> I <br /> - _ _. . . � .. . .._ . ... , _ .. ... � �-- -- <br /> i <br /> � <br /> ACCESS,ORIES <br /> Remote Alarm �rmr c3ii-A� Manual Remote Pull Station�c3o9-n� <br /> � <br /> DESCRIPTION: DESCRIPTION: <br /> Due to different designs of cabinets, different A manual remote pull station is available where local <br /> materials and thicknesses, the sonic signal from the fire codes or circumstances require the capability to <br /> CPU board can in some cases be attenuated to a db manually activate the range top e�ctinguisher system. <br /> (loudness)level that will not activate the shutoff of the � See FIGURE 7 below. <br /> power supply to a range. If this is the case, an � <br /> optional external remote alarm is available to help p } r� � -�r�� <br /> f'�, - <br /> maintain the higher db(loudness)level to optimize the ��Ft��� Y E;:�:;`�F�'� <br />� operation of the electric/gas shutoff for the stove. �,t�{r0 Z' � �� <br /> St'3� �' l '_ �'Jp� <br /> %�,�:i �°�_',�'�_ � �ii�..:.:-� <br /> 48"(4 Ft.) ' �, �o�j '� `�;,''� <br />', � FIGURE 7 <br /> �000c � <br /> �` acoo <br /> ' U o o J o <br /> a � o o �, f Manual activation of the system will cause the <br /> 0 0�°,�:, extinguisher unit to fully discharge extinguishing <br /> �a o d� , agent, shut off the range top bumers and activate the <br /> i alarm or other electrical accessory. Once activated, <br /> the automatic sequence cannot be interrupted. <br /> FIGURE 5 The manual pull station is installed at a height not <br /> exceeding 60"from the floor and should be located in <br /> the path of exit.Avoid locating the manual pull station <br /> Installation: where the occupant would have to reach over the <br /> If the remote alarm is required,perform the following range top-cooking element to activate the system. <br /> installation steps. (Some jurisdictions require certain distances.) <br /> • Mount the remote alarm in a convenient location <br /> above the stove on the underside of the range NOTE: An Identification sign shall be installed <br /> hood or cabinet. indicating "NOT BUILDING FIRE ALARM PULL <br /> • Feed the cable wire through the access hole into � STATION." <br />' the system enclosure. � - <br /> • Position the cable wire on the same side of the Installation: <br /> Cylindef aS the SenSOf WlfeS. . Determine the best location for the manual pull station. <br /> • Connect the cable wire connector to location"P2" The location must be accessible as required. <br /> designation on the CPU board. (See FIGURE 6) . Install cable in conduit or attach using cable Gamps as <br /> below. required byjurisdiction. <br /> • Verify that external alarm is working during � • Feed the cable wire through the access hole into the <br />� system checkout. � system enclosure. <br /> • Position the cable wire on the same side of the cylinder <br /> ��,':.�+° I as the sensor wires <br /> ,<=�°�°fl�`��r' <br /> �� ��1� � • Connect (overiap sensor terminals) the cable wire <br /> spade terminals to location "P1-3 8� 4" designation on <br /> � a� Main CPU. (See FIGURE 8) below. No polarity <br /> � •• * . required on wires. <br /> . �' i Verify that manual remote pull station is working during <br /> � system checkout. <br /> � � <br /> • ��o �J�.�u � �.. l..,.Y�N�'_ <br /> � ��5Y'✓ <br /> �� ,o•itFnv' �� � �� a,�. �� <br /> O° <br /> FIGURE 6 Q �- o 0 0��� FIGURE 8 �6!Q_� y,�P�� <br /> B ° ° I 3_ _'`;-;r:1 <br /> S$ �g � � �b� I ��,:�;:.�` <br /> �: s� � <br /> 360"(30Ft.) <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.