G310A-A <br /> Page 20 Revised February 20, 2007 <br /> TROUBLESI�OOTING GUIDE <br /> CAUTION: DURING CHECK OUT PROCEDURES MAKE SURE SAFETY PULL PIN IS INSTALLED. <br /> Niain CPU Board �P�N�3oz� . Verify that the Interconnect cable wires to Main <br /> CPU control board are attached correctly on P1 <br /> Problem: Continuous Alarm terminal strip 5(com)and 7(N/O). <br /> Check the following: (See FIGURE 3) • Verify power is getting to stove by turning on <br /> burner. If, no power, disconnect electric shutoff <br /> e During test procedures, Push K1 on Main CPU to and plug stove directly into the wall. <br /> disable the alarm. <br /> • If power to the stove exists by plugging directty <br /> • Verify terminals are tight on P1 terminal strip. into the wall, replace electric shutoff. If no power <br /> exist to the stove,check site condition. <br />' • Sensor cable wires are not shorted or frayed. <br /> • For hardwired versions, have a certified <br />� • Open or bad connection to solenoid release electrician verify that the source power is <br /> valve. supplied to the same side of the contactor as the i <br />' orange wires from the ESO printed circuit board. <br /> • Bad sensor-replace one sensor at a time. <br /> Problem: No Shutoff Activation usinq the <br /> Interconnect Cable <br /> Release Solenoid Latch <br /> • Perform Electric Shutoff Checkout procedures on <br /> Page 16 that are applicable to right configuration. <br /> PI'Oblem: No Activation of Latch <br /> • Confirm that power is supplied to the stove <br /> Check the following: (See FIGURE 3) through the electric shutoff. <br /> • Terminals are tight on Main CPU P1-8&9. . Verify that the connector on the "interconnect <br /> cable" is plugged into the electric shutoff and that <br /> • Verify the red wire goes to P1-8 and the black the other end of the interconnect cable is connect <br /> wire goes to P1-9. to P1-5&7 on the Main CPU board. <br /> • Use a Multi-meter to measure the DC Voltage . Short across the interconnect cable terminated <br /> signal on P1-8 (+) and P1-9 (-) during system on P1-5&7 of the Main CPU board with a wire to <br /> checkout. If signal does not appear, replace complete the circuit in shut off Activation should <br /> CPU board. If signal exists, perform next step. occur. If activation does NOT occur, replace the <br /> shutoff. <br /> • Disconnect wires from P1-8 8 P1-9. Use a 9-volt <br /> battery and place the red wire on positive and the . If activation occurs, reset the shutofF and perForm <br /> black wire on negative. If solenoid DOES NOT INTERCONNECT CABLE TEST PROCEDURES <br /> ACTIVATE use a Multi-meter to measure the on Page 16 817 Be sure to keep short across <br /> resistance between the two wires. The resistance sensor for approximately 20-30 seconds to <br /> should be approximately 190 ohms. If no enable "Fire Detect Mode". If activation does <br /> indication of resistance, replace solenoid. NOT occur at this point, replace the Main CPU <br /> board. <br /> Electric Shu#offs cP�N�3,s� <br /> P�Oblem: No Shutoff Activation using the <br /> Verify the configuration and determine if the electric Sonic ReCeiver AssemblV <br /> shutoff is 1-Sonic or 2- Non-sonic and whether it is a <br /> 3 Prong,4 Prong or Hardwired version. . PerForm "Sonic Receiver Test Procedures" <br /> Checkout on Page 16. <br /> PPOblel7'i: No Electrical Power To Stove usinq <br /> Interconnect Cable Confiquration • Check that"Sonic Receiver Assembly"is plugged <br /> into shutoff. Power"ON"light will be lit. <br /> • Perform Electric Shutoff Checkout procedures on <br /> Page 16 that are applicable to right configuration. <br />