<br /> TABLE 2B:STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Offl or RECOVER
<br /> SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
<br /> System De�k Top Insulation Layer MDP
<br /> Base Insulation Layer Roof Cover/Adhesive
<br /> No. (See Note 1) Type Fasteners Attach (psf)
<br /> SC-11 Min.22 ga.,type B,Grade 33 steel Min.1.5"thick,one or more layers,any Min 7/16"APA or TECO rated OSB Trufast SIP LD 1 per 3.2 ft2 Mule-Hide TPO-c/WBBA 2000 or 3�5•
<br /> or min.2,500 psi concrete combination,loose laid Fasteners Mule-Hide TPO-c Bonding Adhesive
<br /> Min.22 ga.,type B,Grade 33 steel (Optional)One or more layers,any Min.l-inch Poly I50 2,ACFoam II Mule-Hide TPO-c/WBBA 2000 or
<br /> SC-12 or min.2,500 si concrete combination,loose laid or ENRGY 3 See Note 2 1 per 1.6 ftZ 37.5•
<br /> P Mule-Hide TPO-c Bonding Adhesive
<br /> SC-13 Min.22 ga.,type B,Grede 33 steel Min.1.5-inch thick,one or more layers, Min.0.5-inch H-Shield HD See Note 2 1 per 2.67 ft= Mule-Hide TPO-c/Mule-Hide TPO-c 3�5•
<br /> or min.2,500 psi concrete any combination,loose laid Bonding Adhesive
<br /> SC-14 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min 0.25-inch SECUROCK Gypsum- See Note 2 1 per 2.67 ft= Mule-Hide TPO-c/WBBA 2000 or 3�St
<br /> or min.2,500 psi concrete any combination,loose laid Fiber Roof Board Mule-Hide TPO-c Bonding Adhesive
<br /> SC-15 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min 0.50-inch SECUROCK Gypsum- See Note 2 1 per 3.2 ft= Mule-Hide TPO-c/WBBA 2000 or -45.0'
<br /> or min.2,500 psi concrete any combination,loose laid Fiber Roof Board Mule-Hide TPO-c Bonding Adhesive
<br /> SC-16 Min.22 ga.,type B,Grede 33 steel Min.1.5-inch thick,one or more layers, Min 0.625-inch SECUROCK See Note 2 1 per 4.0 ft2 Mule-Hide TPO-c/WBBA 2000 or _q5.0•
<br /> or min.2,500 psi concrete any combination,loose laid Gypsum-Fiber Roof Board Mule-Hide TPO-c Bonding Adhesive
<br /> SC-17- Min.22 ga.,type B,Grede 33 steel Min.1.5"thick,one or more layers,any _Min_7/16"A?A or_TECO_rated-058-_Trufast SIP LD _1_per_2.67 ft? Mule-Hide TPO-c/WBBA 2000 or -45.0'
<br /> or min.2,500 psi concrete combination,loose laid Fasteners Mule=Hide TP0=c8onding-Adhesive-- -
<br /> SC-18 Min.22 ga.,type 0,Grade 33 steel One or more layers,any combination, Min 7/16"APA or TECO rated OSB See Note 2 1 per 3.6 ft� Mule-Hide TPO-c/WBBA 2000 or _q5.0'
<br /> or min.2,500 psi concrete loose laid Mule-Hide TPO-c Bonding Adhesive
<br /> SC-19 Min.22 ga.,type B,Grade 33 steel (Optional)One or more layers,any Min.l-inch Poly ISO 1,H-Shield,H- See Note 2 1 per 1.6 ftZ Mule-Hide TPO-c/WBBA 2000 or -45.0•
<br /> or min.2,500 psi concrete combination,loose laid Shield CG Mule-Hide TPO-c Bonding Adhesive
<br /> Min.22 a., e B,Grade 33 steel 0 tional One or more la ers,an Min.1.5-inch ACFoam II,Poly ISO
<br /> SC-20 g TyP � P � Y y 2,H-Shield,Poly ISO 1,H-Shield See Note 2 1 per 2.0 ft� Mule-Hide TPO-c/WBBA 2000 or _q5.0"
<br /> or min.2,500 psi concrete combination,loose laid CG,ENRGY 3 Mule-Hide TPO-c Bonding Adhesive
<br /> Min.22 a., e B,Grade 33 steel Min.2.0-inch ACFoam II,Poly I50
<br /> SC-21 g �P (Optional)One or more layers,any Z�H-Shield,Poly ISO 1,H-Shield See Note 2 1 per 4.0 ft� Mule-Hide TPO-c/WBBA 200D or _45.0'
<br /> or min.2,500 psi concrete combination,loose laid CG,ENRGY 3 Mule-Hide TPO-c Bonding Adhesive
<br /> SC-22 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min.0.5-inch H-Shield HD See Note 2 1 per 2.0 ft� Mule-Hide TPO-c/Mule-Hide TPO-c _45.0•
<br /> or min.2,500 psi concrete any combination,loose laid Bonding Adhesive
<br /> SC-23 Min.22 ga.,type B,Grade 33 steel Min.1.5"thick,one or more layers,any Min 7/16"APA or TECO rated OSB See Note 2 1 per 1.9 ft� Mule-Hide TPO-c/WBBA 2000 -52.5
<br /> or min.2,500 psi concrete combination,loose laid
<br /> SC-24 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min 0.5-inch Dens Deck Prime See Note 2 1 per 1.6 ft� Mule-Hide TPO-c/Mule-Hide TPO-c _60.0
<br /> or min.2,500 psi concrete any combination,loose laid Bonding Adhesive
<br /> SC-25 Min.22 ga.,type B,Grede 33 steel Min.1.5"thick,one or more layers,any Min 7/16"APA or TECO reted OSB See Note 2 1 per 1.9 ft� Mule-Hide TPO-c/Mule-Hide TPO-c _75.0
<br /> or min.2,500 psi concrete combination,loose laid Bonding Adhesive
<br /> Exterior Research and Desfgn,LLC.d/b/a Trinity�ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
<br /> Certificat@ of Authorization k9503 � � Revision 3:03/18/2015
<br /> Prepared by: Robert Nfeminen,PE-59166 Appendix 1,Page 6 of 18