TRINITY)ERD
<br /> TABLE 2A: STEEL or CONCREfE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
<br /> SYSTEM TYPE B: MECHANICALLY A7TACHED BASE INSUTATION,BONDED TOP INSULATION,BONDED ROOF COVER
<br /> System Deck Base Insulation Layer Tap Insulation Layer MDP
<br /> No. (See Note 1) Type Fastener Attach Type Attach Roof Cover/Adhesive (Psfl
<br /> Min.22 ga.,type 8, Min.0.5-inch Dens Deck or Dens Min.1.5-inch ACFoam II,Poly I50 2, Mule-Hide TPO-c/WBBA 2000
<br /> SC-1 Grade 33 steel or min. See Note 2 1 per 2.0 ft2 ENRGY 3,Poly ISO 1 or H-Shield followed OBSOD or Mule-Hide TPO-c Bonding -37.5•
<br /> 2,500 psi concrete Deck Prime by Min.0.25-inch Dens Deck Prime Adhesive
<br /> Min.22 ga.,type 8, Min.2-inch Poly ISO 1.H-Shield,H- , Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/WBBA 2000 *
<br /> SC-2 Grade 33 steel or min. Shield CG See Note 2 1 per 4.0 ft Roof Board OB500 or Mule-Hide TPO-c Bonding -37.5
<br /> 2,500 psi conc. Adhesive
<br /> Min.22 ga.,type B, Mule-Hide TPO-c/W88A 2000
<br /> SC-3 Grade 33 steel or min. Min.1.5-inch ACFoam II,Poly I50 See Note 2 1 per 2.0 ftZ Additional layers of base insulation OB500 or Mule-Hide TPO-c Bonding -45.0' I
<br /> 2,500 psi concrete 1,Poly I50 2,H-Shield CG,ENRGY 3 ,'
<br /> Adhesive
<br /> �
<br /> Min.22 ga.,type B, Min.1.5-inch ACFoam II,Poly ISO = Min.0.25-inch Dens Deck,Dens Deck Mule-Hide TPO-c/WBBA 2000 I
<br /> SC-4 Grede 33 steel or min. 1,Poly ISO 2,H-Shield CG,ENRGY 3 See Note 2 1 per 2.0 ft prime OB500 or Mule-Hide TPO-c Bonding -45.0'
<br /> 2,500 psi concrete Adhesive
<br /> Min.22 ga.,type B, Mule-Hide TPO-c/WBBA 2000
<br /> -SG-S—-Grade-33-steel-or-min.—_Min.0.5-inch Dens Deck or Dens See Note 2 1 per 2.0 ft� Min.1.5-inch ACFoam II,Poly ISO 2, OB500 or Mule-Hide TPO-c Bonding -45.0'
<br /> 2,500 psi concrete Deck P�ime - -ENRGY3,-H-Shield orPoly ISO-1 Adhesive -- ----- -
<br /> Min.22 ga.,type B, Mule-Hide TPO-c/WBBA 2000
<br /> SC-6 Grade 33 steel or min. Min.2.0-inch ACFoam II,Poly ISO See Note 2 1 per 4.0 ft� Additional layers of base insulation OB500 or Mule-Hide TPO-c Bonding -45.0•
<br /> 2,500 psi concrete 1,Poly ISO 2,H-Shield CG,ENRGY 3
<br /> Adhesive
<br /> Min.22 ga.,type B, Min.2.0-inch ACFoam II,Poly ISO Min.0.25-inch Dens Deck,Dens Deck Mule-Hide TPO-c/WBBA 2000 ;
<br /> SC-7 Grade 33 steel or min. 1,Poly I50 2,H-Shield CG,ENRGY 3 See Note 2 1 per 4.0 ft' prime OB500 or Mule-Hide TPO-c Bonding -45.0
<br /> 2,500 psi concrete Adhesive
<br /> Min.22 ga.,type B, Min.1.5-inch Poly ISO 1,H-Shield, = Min.0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/WBBA 2000
<br /> SC-S Grade 33 steel or min. H-Shield CG See Note 2 1 per 3.2 ft Roof Board OB500 or Mule-Hide TPO-c Bonding -45.0•
<br /> 2,500 psi conc. Adhesive
<br /> Min.22 ga.,type B, Min.2-inch Poly ISO 1,H-Shield,H- � Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/W BBA 2000 s
<br /> SC-9 Grade 33 steel or min. Shield CG See Note 2 1 per 2.67 ft Roof Board OB500 or Mule-Hide TPO-c Bo�ding -45.0
<br /> 2,500 psi conc. Adhesive
<br /> Min.22 ga.,type B, Min.2-inch Poly I50 1,H-Shleld,H- , Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/WBBA 2000
<br /> SC-10 Grade 33 steel or min. Shield CG See Note 2 1 per 1.6 ft Roof Board OB500 or Mule-Hide TPO-c Bonding -60.0
<br /> 2,500 psi conc. Adhesive
<br /> Exterior Research and Design,LLC,d/b/a Trinity�ERD Evaluation Report M15060.06.09-R3 for FL32772-R3
<br /> Certificate of Authori:atlon q9503 Revision 3:03/1B/2015
<br /> Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 5 of 18