Laserfiche WebLink
TRINITI�}ERD <br /> TABLE iC: WOOD DECKS-NEW CONSTRUCTION,REROOF(Tear-Of�or RECOVER <br /> SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED ROOF COVER <br /> Thermal Barrier Roof Cover <br /> System Roof Deck MDP <br /> No. Type Attach Membrane Fasteners Fastener �p yyidth Lap Spacing Seam Weld (psf) <br /> Spacing <br /> Min.19/32-inch thick Mule-Hide FR Deck <br /> Panel A or C or BarrierTechnology Corp (Optional)Any Mule-Hide EHD 1.5-inch <br /> W-5 "Blazeguard A or C"at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 12-inch o.c. 5-inch 48-inch o.c. -30.0 <br /> attached using No.8 x 2'/:-inch long thermal barrier 2.4 Seam Plates outside <br /> course thread screws spaced 6"o.c. <br /> Min.19/32-inch thick Mule-Hide FR Deck <br /> Panel A or C or BarrierTechnology Corp (Optional)Any Mule-Hide EHD 1.5-inch <br /> W-6 "Blazeguard A or C"at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5-fnch 72-(nch o.c. -52.5 <br /> attached using No.S x 2K-inch long thermal barrier 2.4 Seam Plates outside <br /> course thread screws spaced 6"o.c. <br /> Min.19/32-inch thick Mule-Hide FR Deck <br /> Panel A or C or Barrier Technology Corp (Optional)Any Mule-Hide EHD 1.5-inch <br /> W-7 "Blazeguard A or C"at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5-inch 48-inch o.c. outside -�5.0 <br /> attached using No.S x 2'r4-inch long thermal barrier 2.4 Seam Plates <br /> —course_threadsccews_spaced 6'_o.c. <br /> Min.19/32-inch plywood at max.24-inch (Optional)Any Mule-Hide EHD 48-inch o.c.{over 1.5-inch <br /> W-8 spans attached using Sd ring shank nails approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5.5-inch structurel members) outsfde -�5.0 <br /> spaced 6-inch o.c. thermal barrier 2.4 Seam Plates <br /> TABLE SD:WOOD DECKS—NEW CONSTRUCTION <br /> SYSTEM TYPE F:NON-INSUTATED,BONDED ROOF COVER <br /> System Roof Deck Roof Cover MDP <br /> No. Membrane Application (psf) <br /> Min.15/32-inch thick Mule-Hide FR Deck Panel A or C ar Barrier Technology Corp"Blazeguard A or C"at <br /> w 9 max.24-inch spans attached using No.8 x 2Y4-inch long course thread screws spaced 6"o.c. Mule-Hide TPO-c WBBA 2000 -45.0 <br /> W-10 Min.19/32-inch thick Mule-Hide FR Deck Panel A or C or Barrier Technology Corp"Blazeguard A or C"at Mule-Hide TPO-c WBBA 2000 -52.5 <br /> max.24-fnch spans attached us(ng No.8 x 214-inch long course thread screws spaced 6"o.c. <br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report M15060.06.09-R3 for FL12772-R3 <br /> Certificate of Authorization k9503 � Revision 3:03/18/2015 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 18 <br />