<br /> 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,fiberboard,periite and/or gypsum-based tnsulation board that meets the CL4 requirements of F.A.C.Rule
<br /> 61G20-3 and fs documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when Installed with the roof cover.
<br /> 4, Mfnimum 200 psl,minimum 2-Inch thick Ilghtweight Insulating concrete may be substftuted for rigid insulation board for System Type D(mechanically attached membrane),whereby the membrane fasteners are
<br /> Installed through the LWIC to engage the structural steel or concrete deck. The strudurel deck shall be of equal or greater type,thickness and strength to the steel and concrete deck Iistfngs. Roof decks and
<br /> structurel members shall be in accordance wfth FBC requirements to the satisfacHon of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or PBC Approval documentation.
<br /> 5. Preliminary insulation attachment for System Type D=Min(mum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board.
<br /> 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturers published instructlons:
<br /> 9 Carlisle FAST 100,FAST 1�LV(full); Full-coverage at 1 gal./square.
<br /> D Carllsle FAST 300,FAST 100 W(ribbon): Continuous 0.75 to 1-inch wide rfbbons,l2-Inch o.c.
<br /> D Carlisle Flexible FAST(full): Fuil-coverage at 1 gal,/square.
<br /> D Carlisle Flexible Fast(ribbon): Cont(nuous 0.75 to 1-fnch wide ribbons,l2-inch o,c.
<br /> D Carilsle FAST Dual Cartridge: Continuous 0.75 to i-inch wide ribbons,l2-inch o.c.
<br /> > Carlisle FAST Bag in a Box Adhesive(BIAB): Continuous 0.75 to 1-inch wlde ribbons,l2-inch o.c.using OMG Bag-In-Box PaceCart 2
<br /> ➢ OlyBond 500(OB500): Continuous 0.75 to 1-inch wlde ribbons,l2-inch o.c.using PaceCart or SpotShot
<br /> Note:OlyBond 50D Green may be used where OlyBond SOD is referenced.
<br /> D Note: When muftlple Iayers(s)of Insulatlon and/or coverboard are Jnsta!!ed In rlbbon-applied adheslve,adheslve rlbbons shall be staggered from layer-to-layer a dlstanre of one-half the rl66on spadng.
<br /> .............-- -..___..._,..,y,...___ O :- � ISlCifCE�fPdflTTJf�S'fIIfE�51[1P71 . . � - 8[!Ofl'bd�Iff3'IICJI'bP'ftOFJ � - - B � C ----.-------.......--.,__._...........,.,. ..,... .,..
<br /> 7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the fallowfng thickness Ilmitations may be substituted with the foilowing Maximum
<br /> Design Pressure(MDP)Ifmitatlons. In no case shall these values 6e used to'Increase'the MDP Iistings In the tables;rather if MDP Ifsttng below meets or exceeds that Iisted for a particular system In the tahles,then
<br /> the thinner board listed below may be used as a drop-In for the equivalent th(cker material listed in the table:
<br /> D FAST 100,FAST S00 LV or Flexible FAST: MDP -157,5 psf (Mfn,0.5-inch thick)
<br /> � OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick)
<br /> 8. Bonded palyisocyanurate insulation 6oards shall 6e maximum 4 x 4 ft.
<br /> 9, For mechanically attached components or parttally bonded Insulatlon,the maximum design pressure for the selected assem6ly shall meet or exceed the Zone 1 design pressure determined in accordance w(th FBC
<br /> Chapter 16,and Zones 2 and 3 shall emplay an attachment density designed by a qualifled design professlonal to resist the elevated pressure criteria. Commonly used methods are RAS 117,FM LPD51-29 and
<br /> AN51/SPRI WDi. Assemblies marked with an asterisk'carry the Iimitations set forth in Section 2.2,1.5.1(a)of FM LPDS i-29 for Zone 2/3 enhancements.
<br /> 10. For assem6Ues with all components fully bonded In place,the maximum design pressure for the selected assembly shall meet or exceed critical desl�n pressure determined in accordance with FBC Chapter 16,and no
<br /> rational analysis is perm(tted.
<br /> ii. For mechanlcally attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal reststance. A qualified desfgn prolessional shall review the data for comparison to the
<br /> minimum�equiremenu for the system. Testtng and analysis shall be In acrnrdance with TA5105 or AN51/SPRI FX-1.
<br /> 12. For existing substrates in a bonded recover or re-roof installatfon,the existing roof surface�or existing roof deck shall be examined for compatibiflty and bond performance with the selected adhesive,and the existing
<br /> roof system(for recover)shall be capable of resisting project design pressures on lu own merit to the satisfaction of the AHJ,as documented through fleld uplift testing in accordance with ASTM E907,FM LPDS i-52
<br /> orAfV51/SPRI IA-1,
<br /> 13. For System Type D,steel deck applications,the raof inembrane shall be run with(ts length perpendlcular to the steel deck flutes.
<br /> 14. For Recover Applicatlons using System Type D,the Insulatlon fs optional. Alternatively,min.0.5-Inch HP Recovery Boa�d,SecurShield HD or H-Shield HD or min.0.25-Inch to 0.625•Inch Dens Deck,Dens Deck Prirne,
<br /> SECUROCK Gypsum•Fiber Roof Board or SECUROCK Glass-Mat Roof Board or min.3/8-inch Insuifoam R-Tech EPS or Fan-Fold may be used as a separator board,preliminarily attached priar to roof cover tnstallatian.
<br /> The existing roof system shall be suitahle for a recover application.
<br />� Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluatlon Report C33680.09.10-R10 for FL14083•R10
<br /> Certiflcate of Authorization p9503 Revision 10;10/19/2015
<br />� Prepared by; Robert Nieminen,PE-59166 Appendix 1,Page 2 of 39