My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17524
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17524
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2016 10:13:57 AM
Creation date
11/2/2016 10:13:55 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
16-17524
Building Department - Name
BINGHAM,MATTHEW JAMES
Address
6015 10TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . - ~'''�� <br /> ��T����� ERD <br /> � <br /> Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Fasten 6- <br /> inch o.c.in the laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are <br /> staggered at least 3-feet apart. <br /> 6.3.4.2 Standard Installation with Double Layer,2:12<roof slope<4:12 ' <br /> Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll 12-inch <br /> o.c,in two,equally spaced,staggered center rows. <br /> Continue upslope in a similar manner,with minimum 28.5-inch side-laps and minimum 6-inch end-laps. Fasten 6-inch <br /> o.c. along the low edge and end laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. <br /> Ensure all end laps are staggered at least 3-feet apart. <br /> 6.4 Ti�er PawTM'Roof Deck Protedion: <br /> 6.4.1 Install Tiger PawT""Roof Deck Protection in compliance with manufacturer's published installation instructions and the <br /> requirements for ASTM D226,Type I and II underlayments in FBC Sections 1507 for the type of prepared roof covering <br /> to be installed. . <br /> 6.4.2 Fasteners shall be 1-inch diameter plastic-capped corrosion resistant nails or 1-inch diameter plastic-capped,corrosion <br /> resistant staples. <br /> 6.4.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty'"" SBS Self-Adhering <br /> Base/Ply Sheet;StormGuard� Film Surfaced Leak Barrier; UnderRooP"" 2 Polyester-Surfaced Leak Barrier; UnderRoof'"' <br /> HT High Temperature Leak Barrier; WeatherWatch� Mineral Surfaced Leak Barrier or WeatherWatch� XT Mat <br />' Surfaced Leak Barrier at vulnerable leak areas,including but not limited Yo eaves,valleys,rakes,skylights and dormers. <br /> At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the <br /> underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and <br /> exposed decking. At other areas,install the leak barrier over the underlayment. <br /> 6.4.4 For non-tile roof installations: <br /> 6.4.4.1 Standard Installation with Single Layer;roof slope>4:12 <br /> Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll 12-inch <br /> I o.c.in two,equally spaced,staggered center rows. <br /> Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Fasten 6- <br /> inch o.c.in the laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are <br /> staggered at least 3-feet apart. <br /> 6.4.4.2 Standard Installation with Double Layer;2:12<roof slope<4:12 <br /> Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll 12-inch <br /> o.c.in two,equally spaced,staggered center rows. <br /> Continue upslope in a similar manner,with minimum 22.5-inch side-laps and minimum 6-inch end-laps. Fasten 6-inch <br /> o.c. along the low edge and end laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. <br /> Ensure all end laps are staggered at least 3-feet apart. <br /> 6.5 StormSafe'""Anchor Sheet: <br /> 6.5.1 StormSafeT"'Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. <br /> 6.5.2 Fasteners shall be 1-inch diameter plastic-or steel-capped corrosion resistant nails; corrosion-resistant nails& 1-5/8- <br /> inch tin-caps;or Drill-Tec screws and plates. <br /> 6.5.3 For tile roof installations: <br /> Installation is governed by the FRSA/TRI April 2012(04-12)Installation Manual,5th Edition(Revised). Use is limited to � <br /> the mechanically attached base sheet in the two-ply system beneath UnderRoofl"' 2 Polyester-Surfaced Leak Barrier. <br /> The attachment requirements for StormSafe"" Anchor Sheet shall be adjusted from those in Appendix A,Table 1 of <br /> FRSA/TRI April 2012 (04-12),5`h Edition (Revised)to be proportionate to the width of the StormSafe'"" Anchor Sheet <br /> product. � <br /> 6.5.4 For non-tile roof installations: <br /> Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll 12-inch <br /> o.c.in two,equally spaced,staggered center rows. <br /> Exterior Research and Design,LLC. Evaluation Report 01506.03.12-RS <br /> Certificate of AuthorizaYion N9503 FL15487-RS <br /> Revision 5:04/02/2015 <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.