, , <br /> �f'�I�II�''�E�� <br /> Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Fasten 6- <br /> inch o.c.in the laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are <br /> staggered at least 3-feet apart. <br /> One the same day,install Liberty'"'SBS Self-Adhering Base/Ply;StormGuard�Film Surfaced Leak Barrier;UnderRoof""2 <br /> Polyester-Surfaced Leak Barrier; UnderRoof'"' HT High Temperature Leak Barrier; WeatherWatch° Mineral Surfaced <br /> Leak Barrier or WeatherWatch�XT Mat Surfaced Leak Barrier over the StormSafe'""Anchor Sheet. <br /> 6.6 RoofPro'""SBS-Modified All-Purpose Underlavment and ShinQle-Mate�Roof Deck Protection: <br /> 6.6.1 Install RoofPro'"' and Shingle-Mate° in compliance with manufacturer's published installation instructions and the <br /> requirements for ASTM D226,Type I and II underlayments in FBC Sections 1507 for the type of prepared roof covering <br />� to be installed. A double layer is required for 2:12<roof slope<4:12. No hammer tacks or staples are permitted. <br /> 6.6.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LibertyTM SBS Self-Adhering <br /> Base/Ply Sheet;StormGuard� Film 5urfaced Leak Barrier; UnderRoofn"2 Polyester-Surfaced Leak Barrier; UnderRoof7"' <br /> HT High Temperature Leak Barrier; WeatherWatch� Mineral Surfaced Leak Barrier or WeatherWatch� XT Mat <br /> Surfaced Leak Barrier at vulnerable leak areas,including but not limited to eaves,valleys,rakes,skylights and dormers. <br /> At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the <br /> underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and <br /> exposed decking. At other areas,install the leak barrier over the underlayment. <br /> 6.7 VersaShield�Fire-Resistant Roof Deck Protection: <br /> 6.7.1 Install VersaShield° Fire-Resistant Roof Deck Protection in compliance with manufacturer's published installation <br /> instructions and the requirements for ASTM D226,Type I and II or ASTM D4869 underlayments in fBC Sections 1507 <br /> for the type of prepared roof covering to be installed. A double layer is required for 2:12 < roof slope <4:12. No <br /> hammer tacks or staples are permitted. <br /> 6.7.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LibertyTM SBS Self-Adhering <br /> Base/Ply Sheet;StormGuard� Film Surfaced Leak Barrier; UnderRoof'"'2 Polyester-Surfaced Leak Barrier; UnderRoof'"' <br /> HT High Temperature Leak Barrier; WeatherWatch� Mineral Surfaced Leak Barrier or WeatherWatch� XT Mat <br /> Surfaced Leak Barrier at vulnerable leak areas,including but not limited to eaves,valleys,rakes,skylights and dormers. <br /> At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the <br />� underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and <br /> exposed decking. At other areas,install the leak barrier over the underlayment. <br /> 7. BUILDING PERMIT REQUIREMENTS: <br /> As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. <br /> 8. MANUFACiURING PLANTS: <br /> Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 Qq requirements. <br /> 9. QUALITY ASSURANCE ENTITY: <br /> UL,LLC.—QUA9625;(847)664-3281 <br /> -END OF EVALUATION REPORT- <br /> Exterior Research and Design,LLC. Evaluation Report 01506.03.12-RS <br /> Certificate ofAuthorizatian JI95o3 FL15487-RS <br /> Revisian 5:04/02/2015 <br /> Page 5 of 5 <br />