My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17041
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17041
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2017 8:41:31 AM
Creation date
2/17/2017 8:39:09 AM
Metadata
Fields
Template:
Building Department
Company Name
PLAZA 54
Building Department - Doc Type
Permit
Permit #
16-17041
Building Department - Name
PLAZA 54 LLC
Address
38435 COUNTY ROAD 54
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 J <br />, EnCon Services, Inc. <br /> Sign Design Calculations � <br /> Job Description PREPARED BY: EnCon Services, Inc. i <br /> Non-Illuminated Sign Frames 2272 Jaudon Road I <br /> i 38435 CR 54 Dover, FL 33527 ', <br /> Zephyrhills, Florida P 813-655-3373 <br /> 2'x 10'wall sign frame F 813-655-9814 <br /> Design per Florida Building Code,5th Edition(2014), Section 16 Wind Load, FLEB#9394 <br /> ASCE 7-10, Load Case: D+0.6W ! <br /> Design Specifications <br /> Risk Category II <br /> Kzt 1 <br /> Exposure Factor C <br /> Kd 0.85 <br /> � 0 50 m h ```����UIIIIII11/1/�j���i <br /> c p ) oo� N P. PRF �•�. <br /> Wind Pre su ei s�2 �P�5, H <60 Feet `�����Q:;� E N S�sy���' <br /> -'?Q:' No 7 6 � <br /> _ ; � <br /> Sign Information — * ' — <br /> Height 2.00 (ft) ��' •' � <br /> . <br /> G'A".� S ATE OF �: � <br /> Width 10.00 (ft) � � . � !(�� <br /> Distance g ade to top O 30 (ft) ����i���ss' �R 1���`�`��� <br /> �����iii�miui t�������� <br /> Wind Shear Force 10.48 (Ib) <br /> Weight of Sign 60 (Ib) DATE SIGNED: <br /> Total Shear Force= 60.91 (Ib) 2/2/2016 <br /> Total Tension Force= 806.08 (Ib) <br /> Required Provide <br /> Fastener size(Nominal) 3/8 3/8 <br /> Minimum number of fasteners 6 6 <br /> Shear Force per fastener(Ib) 10.2 280 � <br /> Tension Force per fastener(Ib) 134.3 352 <br /> Combination Tension and 0.42 <1 O.K. <br /> Sheer ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> I WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT(3'EMBEDMENn THROUGH BLOCKING <br /> EIFS OVER 518'PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-112°EMBEDMEN� <br /> SOLID CONCRETE WEDGE ANCHOR(2-112°EMBEDMENn <br /> CMU,SOLID CONCRETE,BRICK , HILTI HIT ROD WIHY-20 ADHESIVE(3112'EMBEDMEN� <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS <br /> 2/2/2016 <br /> Non Illuminated Sign Fremes Zephyrhills 2-0 x 10-0 WS Frank Tampa Sign <br />
The URL can be used to link to this page
Your browser does not support the video tag.