Laserfiche WebLink
� EnCon Services, Inc. <br />' Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. I�, <br /> Non-Illuminated Sign Frames 2272 Jaudon Road I, <br /> II 38435 CR 54 Dover, FL 33527 <br /> Zephyrhills, Florida P 813-655-3373 ' <br /> 2'x 10'wall sign frame F 813-655-9814 <br /> Design per Florida Building Code,5th Edition(2014), Section 16 Wind Load, FLEB#9394 I <br /> ASCE 7-10, Load Case: D+0.6W � <br /> Design Specifications <br /> Risk Category II <br /> Kzt 1 <br /> Exposure Factor C <br /> I Kd 0.85 <br /> Kz 0.98 <br />' V 150 (mph) ```����U1111111ffU/�j�',' <br /> .°�� N P� ►'R ���'. <br /> GCp-GCpi 1.4 Zone 5, H <60 Feet �O Q;.••'E •�sA"�ii <br /> WindPressure 67.2 (psfl �'��.•��.�C NSF'•i���i� <br /> �;� <br /> '�Q:' No 77 6 ' <br /> ` • - <br /> = * : : * � <br /> Sign Information — • • <br /> �•�: • � <br /> Height 2.00 (ft) • <br /> Width 10.00 (ft) � O•.�. S ATE OF . ��` <br /> Thickness 0.13 (ft) ��i��' ��O R 1�P'������� <br /> Distance grade to top 30 (ft) ���i��jsS�QNAL���O�� <br /> llllllllllllU� <br /> Wind Shear Force 10.48 (Ib) <br /> Weight of Sign 60 (Ib) DATE SIGNED: <br /> Total Shear Force= 60.91 (Ib) 2/2/2016 <br /> Total Tension Force= 806.08 Ib <br /> � ) <br /> Require Provi ed <br /> Fastener size(Nominal) 3/8 3/8 <br /> Minimum number of fasteners 6 6 <br /> Shear Force per fastener(Ib) 10.2 280 <br /> Tension Force per fastener(Ib) 134.3 352 <br />� Combination Tension and 0.42 <1 O.K. <br /> Sheer ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING IAG BOLT(3°EMBEDMEN�THROUGH BLOCKING <br /> EIFS OVER 518'PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-1/2"EMBEDMENn <br /> SOLID CONCRETE WEDGE ANCHOR(2-112°EMBEDMEN� <br /> CMU,SOLID CONCRETE,BRICK HILTI HIT ROD WIHY-20 ADHESIVE(3112'EMBEDMEN� <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS <br /> 2/2/2016 <br /> Non Illuminated Sign Frames Zephyrhills 2-0 x 10-0 WS Frank Tampa Sign <br />