' Page 2 of 3 <br /> � . <br /> FL# Model,Number or Name Description <br /> 4904 1 Wood-edge Steel Side-Hinged Door Units 6'-8"Opaque I/S and O/S Single Door <br /> Limits of Use Certification Agency Certificate <br /> Approved Por use in HVHZ:Yes FL4904 R7 C CAC NI0061 IO.Ol.pdf <br /> Approved for use outside HVHZ:Yes Quality Assur:►nce Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+76.0/-76.0 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the Florida Building FL4904 R7 [I_FL0128_pdf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verifed By National Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by[ndependent Third Party: <br /> Buildings and Other Structures,does not exceed the design pressures Evaluation Reports <br /> listed.3'-0"x 6'-8"max nominal size.When large missile impact FL4904 R7 AE 504A.ndf <br /> resistance is required,hurricane protective system is NOT required.See Created by Independent Third Party:Yes <br /> DWG-MA-FL0128-OS for details. <br /> 4904.2 Wood-edge Steel Side-Hinged Door Units 8'-0"Opaque I/S and O/S Single Door <br /> Limits of Usc Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R7 C CAC NI006110.02.pdf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expir�tion Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+70.0/-70.0 Installation Instructions <br /> Othcr:Evaluated for use in locations adliering to the Florida Building FL4904 R7 II FL0129.adf <br /> Code including tlie High Velocity Hurricane Zone,and where pressure Verified By•National Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by Independent Third Party• <br /> Buildings and Other Structures,does not eaceed the design pressures Evaluation Reports <br /> listed.3'-0"x 8'-0"max nominal size.When large missile impact FL4904 R7 AE 503A.pdf <br /> resistance is required,hurricane protective system is NOT required.See Created by Independent Third Party:Yes <br /> DWG-MA-FL0129-OS for details. <br /> I 4904.3 Wood-edge Steel Side-Hinged Door Units 6'-8"Opaque[/S and O/S Door w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R7 C CAC NI006110.Ol.pdf <br />� Approved for usc outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+55.0/-55.0 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the Florida Building FL4904 R7 II FL0128.pdf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verified By•National Accreditation&Management Insti[ute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by Independent Third Party• <br /> Buildings and Other Structures,does not exceed the design pressures Evaluation Reports <br /> listed. 12'-0"x 6'-8"max nominal size.Wlien large missile impact FL4904 R7 AE 502A.odf <br /> resistance is required,hurricane protective system is NOT required on Created by Independent Third Party:Yes <br /> opaque panels,but is required on glazed panels.See DWG-MA-FL0128- <br /> OS <br /> 4904 4 Wood-edge Steel Side-Hinged Door Units 8'-0"Opaque[/S Door w/or w/o Sidelites <br /> Limits of Use Certitication Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R7 C CAC NI00611,0,02,pdf <br /> Approved for use outsidc HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Im pact Resistant:Yes 12/3 l/2020 <br /> Design Pressure:+45.0/-50.0 Installation Instructions <br /> Othcr:Evaluated for use in locations adhering to the Florida Building FL4904_R7 II FL0129.pdf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verified By:National Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by Independent Third Party• <br /> Buildings and Other Structures,does not eaceed the design pressures Evaluation Reports <br /> listed. 12'-0"x 8'-0"max nominal size.When large missile impact FL4904 R7 AE SOIA.qdf <br /> resistance is required,hurricane protective system is NOT required on Created by Independent Third Party•Yes <br /> opaque panels,but is required on glazed panels.See DWG-MA-FL0129- <br /> OS <br /> 4904.5 Wood-edge Steel Side-Hinged Door Units 8'-0"Opaque O/S w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R7 C CAC NI006110.02.�df <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+50.0/-45.0 Installation Instructions <br /> Other:Evaluated for use in locations adliering to the Florida Building FL4904 R7 II FL0129.pdf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verified By•National Accreditation&Management Instimte <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by Independent Third Party• <br /> Buildings and Other Structures,does not exceed the design pressures Ev�luation Reports <br /> listed. 12'-0"x 8'-0"max nominal size.When large missile impact FL4904_R7_AE_SOIA;,pdf <br /> resistance is required,hurricane protective system is NOT required on Created by[nclependent Third Party�Yes <br /> http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqteluIwHNbblSc... 1/23/2016 <br />