Laserfiche WebLink
� Page 3 of 3 <br /> : . <br /> opaque panels,but is required on glazed panels.See DWG-MA-FL0129- <br /> O5. <br /> 4904.6 Wood-edge Steel Side-Hinged Door Units 6'-8"Glazed I/S and O/S Door w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R7 C CAC NI0061_]0_03,.pdf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:No 12/31/2020 <br /> Design Pressure:+50.5/-50.5 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the Florida Building FL4904 R7 II FL0130.pdf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verified By•National Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by Independent Third Party• <br /> Buildings and Other Structures,does not exceed the design pressures Evaluation Reports <br /> listed. 12'-0"a 6'-8"max nominal size.When large missile impact FL4904 R7 AE 502A.pdf <br /> resistance is required,hurricane protective system is required.See DWG- Created by Independent Third Party•Yes <br /> MA-FL0130-OS for details. - <br /> 4904.7 Wood-edge Steel Side-Hinged Door Units 8'-0"Glazed I/S Door w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R7 C CAC NI006110�04.pdf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Imp�ct Rcsistant:No 12/31/2020 <br /> Design Pressure:+40.0/-45.0 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the Florida Building FL4904 R7 II FL0131.pdf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verified By National Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by Independent Third Party: <br /> Buildings and Other Structures,does not exceed the design pressures Evaluation Reports <br /> listed. 12'-0"x 8'-0"max nominal size.When large missile impact FL4904 R7 AE SOIA.pdf <br /> resistance is required,hurricane protective system is required.See DWG- Created by Independent Third Party:Yes <br /> MA-FL0131-OS for details. <br /> 4904.8 Wood-edge Steel Side-Hinged Door Units 8'-0"Glazed O/S Door w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R7 C CAC NI006110.04.pdf <br /> Approved for usc outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Imp�ct Resistant:No 12/31/2020 <br /> Design Pressure:+45.0/-40 0 Installation Instructions <br /> Other:Evaluated for use in locations adliering to the Florida Building FL4904 R7 [I FL0131.adf <br /> Code including the High Velocity Hurticane Zone,and where pressure Verified By•National Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by[ndependent Third Party• <br /> Buildings and Other Structures,does not exceed the design pressures Evaluation Reports <br /> listed. 12'-0"x 8'-0"max nominal size.When large missile impact FL4904 R7 AE SOIA.pdf <br /> resistance is required,hurricane protective system is required.See DWG- Created by Independent Third Party•Yes <br /> MA-FL0131-OS for details. <br /> http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqteluIwHNbblSc... 1/23/2016 <br />