My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17113
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17113
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2017 10:27:54 AM
Creation date
2/20/2017 10:27:51 AM
Metadata
Fields
Template:
Building Department
Company Name
FIRST PRESBYTERIAN CHURCH
Building Department - Doc Type
Permit
Permit #
16-17113
Building Department - Name
FIRST PRESBYTERIAN CHURCH
Address
5601 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Insulation C303.2.1 Envelope Exterior insulation is protected from damage with � � � <br /> a protective material.Verification for exposed <br /> foundation insulation may need to occur during <br /> Foundation Inspection. <br /> Insulation C402.2.1 Envelope Insulation intended to meet the roof insulation � � � <br /> requirements cannot be installed on top of a <br /> suspended ceiling.Mark this requirement <br /> compliant if insulation is installed accordingly <br /> Controls C405.2.4 Exterior Lighting Automatic lighting controls for exterior lighting � � � <br /> installed. <br /> Wattage C405.6 Exterior Lighting Exterior grounds lighting over 100 W provides>60 � � ❑ <br /> Im/W unless on motion sensor or fixture is exempt <br /> Watta e from scope of code or from extemal LPD. <br /> 9 C405.6.2 Exterior Lighting Exterior lighting power is consistent with what is ❑ � � <br /> shown on the approved lighting plans, <br /> demonstrating proposed watts are less than or <br /> Controls equal to allowed watts. <br /> C405.2.2.1 Interior Lighting Automatic controls to shut off all building lighting � �I � <br /> installed in all buildings. <br /> Controls C405.2.1 1 Interior Lighting Independent lighting controls installed per � � � <br /> approved lighting plans and all manual conVols <br /> readily accessible and visible to occupants. <br /> Controls C405.2.1.2 Interior Lighting Lighting controls installed to uniformly reduce the � � � <br /> IighGng load by at least 50°/,. <br /> Controls C405.2.2.3 Interior Lighting Daylight zones provided with individual controls � � � <br /> that control the lights independent of general area <br /> lighting. <br /> Controls C405.2.3 Interior Lighting Sleeping units have at least one master switch at � � � <br /> the main entry door that controls wired luminaires <br /> and switched receptacles. <br /> Controls C405.2.2.2 Interior Lighting Occupancy sensors installed in required spaces. ❑ � � <br /> Controls C405.22.3 interior Lighting Primary sidelighted areas are equipped with ❑ ❑ � <br /> required lighting controls. <br /> Controls C405.2.2.3 Interior Lighting Enclosed spaces with daylight area under � � � <br /> skylights and rooftop monitors are equipped with <br /> required lighting controls. <br /> Controls C405.2.3 Interior Lighting Separate lighting control devices for specific uses � � � <br /> installed per approved lighting plans. <br /> Controls C405.3 Interior Lighting Fluorescent luminaires within odd numbered lamp � � � <br /> configurations that are with 10 feet center to <br /> center(if recess mounted)or are within 1 foot <br /> edge to edge(if pendant or surFace mounted) <br /> shall be tandem wired. <br /> Wattage C405.4 Interior Lighting Exit signs do not exceed 5 watts per face. ❑ � � <br /> Wattage C405.2.3 Interior Lighting Additional interior lighting power allowed for � � � <br /> special functions per the approved IighGng plans <br /> and is automatically controlled and separated <br /> from general lighting. <br /> Wattage C405.5.2 Interior Lighting Interior installed lamp and fixture lighting power is � ❑ � <br /> , consistent with what is shown on the approved <br /> lighting plans,demonstrating proposed watts are <br /> HVAC less than or equal to allowed watts. <br /> C403.2.4.5 Mechanical Freeze protection and snow/ice melting system � � � <br /> sensors for future connection to controls. <br /> HVAC C403.2.3 Mechanical HVAC equipment efficiency verified. � � � <br /> Air Leakage C402.4.5.1 Envelope Stair and elevator shaft vents have motorized � � � <br /> dampers that automatically close. <br /> Air Leakage C402.4.5.2 Envelope Outdoor air and exhaust systems have motorized � � � <br /> dampers that automatically shut when not in use <br /> and meet maximum leakage rates.Check gravity <br /> HVAC dampers where allowed. <br /> C403.2.5.1 Mechanical Demand control ventilation provided for spaces � � � <br /> >500 ft2 and>25 people/1000 ft2 occupant <br /> density and served by systems with air side <br /> economizer,auto modulating outside air damper <br /> control,or design airflow>3,000 cfm. <br /> EnergyGauge Summit0 Fla/Com-2014.TAM 2014-1.0 Compliant Software.Effective Date:June 30,2015 <br /> 2/25/2016 I <br /> Page 9 of 13 ' <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.