My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17113
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17113
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2017 10:27:54 AM
Creation date
2/20/2017 10:27:51 AM
Metadata
Fields
Template:
Building Department
Company Name
FIRST PRESBYTERIAN CHURCH
Building Department - Doc Type
Permit
Permit #
16-17113
Building Department - Name
FIRST PRESBYTERIAN CHURCH
Address
5601 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ _._ _ ____ � <br /> . . . ' <br /> ' HVAC G4Q3.2.8.'! Mechanical Piping Insulafion exposed to weather is protected � � � <br /> from damage(due ta sun,moisture,wind,etc.). <br /> HVAC C403.2.7 Mechanical HVAC ducts and plenums insulated. Where ducts � � � <br /> or plenums are installed in or under a slab, <br /> verification may need to occur during Faundatian <br /> Inspection. <br /> NVAC C403.2.8 Mechanical Thermally ineffective panel surfaces of sensible � � � <br /> heating panels have insulatian>=R-3.5. <br /> HVAC C403.2.7 Mechanica! Ducts and plenums sealed based on static ❑ � � ' <br /> pressure and lacatian. <br /> � HVAC C4Q8.2.2.1 Mechanicai Air outlefs and zone terminal devices have means � � � ' <br /> � far air batancing. . � <br /> HVAC C403.2.6 Mecfianical Exhaust air energy recove►y on systems meeting � � � <br /> Tabte C403.2.6 <br /> � HVAC C4p3.2.11 Mechanica! Unenclosed spaces that are heated use oniy � � � <br /> � radiant heat. <br /> NVAC C4432.4.1 Mechanfca! Hea6ng and coaling to each zane is confrol(ed by � � � � <br /> a thermastat controt. I <br /> HVAG - C403.2.4.2 Mechanical Thermostatic controls have a 5°F deadband. � � � � <br /> HVAC C403.2.4.2 Mechanical Temperature controls have setpoint overlap � � � � <br /> restrictions. � <br /> HVAC C403.2.4.3 Mechanicat Each zane equipped with setback con#rots using � � ❑ <br /> autamatic time cioak or programmabfe control � <br /> system. <br /> HVAC C4032.4.3 Mechanica! Automatic ConVots:Setback to 55°F(heat)and � � � i <br /> 85°F(cool);7-day elock,2-haur occupant <br /> averride,'!Q-hourtrackup <br /> SYSTEM_SPECIFIC C404.3 Mechanica! Temperature controls instalied on service water � � � <br /> heating systems(910°F for dwelling units and <br /> lavafaries in pub!!c resVooms and 84°F for other <br /> occupancies.) <br /> SYSTEM_SPECIFIC C404.4 Mechanicel Automatic time switches fnstalled ta automaticafly � � � <br /> switch off the recirculating hot-water system or <br /> heat trace. <br /> SYSTEM_SPECIFIC C404.2 Mechanical Heat traps installed on non-circulating storage � � � <br /> watertanks. <br /> SYSTEM_SPECIFIC C403.2.3 Mechanical PTAC and PTHP with slseves 16 in.by 42 in. � � � <br /> labeled for replacemenf only as per Footnote b to <br /> Table G443.2.3{3}. <br /> SYSTEM_SPECIFIC C409.4.2 Mechanical VAV fan>=7.5 hp are driven by mechanica!or � � � <br /> electrical variable speed ddve,or dr+ven by <br /> vane-axia!with variable spesd blades,ar operate <br /> with motor demand<=30°10 design kW at 50°!0 <br /> design flow-calculations required <br /> SYSTEM_SPECIFIC C403,2.8 Mechanical HVAC piping insulation thickness. Where piping � � � <br /> is instailed in or under a slab,verification may <br /> need to occur during Foundatian Inspection. <br /> SYSTEM_SPECIFtC C4d3.2.71,3 Mechanica� Ductwark operating>3 in.water column requires � ❑ � <br /> air teakage testing. <br /> SYSTEM_SPECIFIC C403.3.1,G4Q3.3.L1 Mechanical Air economizers provided where required,meei � � � <br /> the requirements for design capacity,conVol <br /> signal,ventilation controis,high-limitshut-off, <br /> � j integrated economizer control,and provide a <br /> means to relieve excess outside air during <br /> i operation. <br /> SYSTEM_SPECiFIC C403.3.1,C403.4 1 Mechanical Water ec000mizers provided where required, � � � <br /> meet the requirements for design capacity, <br /> , mauimum pressure drop and integrated <br /> economizer controi. <br /> SYSTEM_SPEGIFIC C4d3.4.1.4 Mecfianical Economizer operation will not increase heating � � � <br /> energy use during normat operation. <br /> SYSTEM_BPEC�FiC C403.4.5 Mechanical Zane controls can limit simultaneous heating and ❑ � � <br /> cooling and sequence heating and cooling to each <br /> zone. <br /> SYSTEM_SPECIFIC C403.A.3.1 Mechanical Three-pipe hydronic systems using a common � ❑ � <br /> , retum for hot and chilled water are not used. <br /> EnergyGauge Summit0 Fla/Com-2014.TAM 2014-1.0 Compliant Sofiware.Effective Date:June 30,2015 <br /> 2/2SI2016 Page 1Q of 13 � <br /> i <br /> � � <br /> I '' <br /> � + <br /> � � <br />
The URL can be used to link to this page
Your browser does not support the video tag.