My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16749
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16749
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2017 1:33:19 PM
Creation date
2/21/2017 1:33:17 PM
Metadata
Fields
Template:
Building Department
Company Name
WALNUT GROVE TOWNHOMES
Building Department - Doc Type
Permit
Permit #
15-16749
Building Department - Name
BUTTERFIELD MOBILE HOME SERVICE
Address
37756 PRAIRIE ROSE LP LOT 55
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� -� wrightsoft� Manual S Compliance Report Da e: R11I15456 <br /> Entire House By: JND <br /> Bahr's Propane Gas �AC Inc <br /> 4441 Allen Rd,Zephyrhills,FL33541 Phone:813782-5013 <br /> � • ' • • <br /> For: Butte�eld Quadplex Unit 6-1 <br /> 4408 Court St, Zephyrhills, FL 33542 <br /> • • • • • <br /> Design Conditions <br /> Outdoor design DB: 91.0°F Sensible gain: 20741 Btuh Entering coil DB. 79.2°F <br /> Outdoor design WB: 76.0°F Latent gain: 3474 Btuh Entering coil WB: 64.3°F <br /> Indoor design DB: 75.0°F Total gain: 24216 Btuh <br /> Indoor RH: 50% Estimated airflow: 927 cfm <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: Split AC <br /> Manufacturer: Tempstar or Eqv. Model: N4A330A(G)KC'+FXM4X30'*A" <br /> Actual airtlow: 927 cfm <br /> Sensible capacity: 20850 Btuh 101% of load <br /> Latent capacity: 6950 Btuh 200°/a of load <br /> Total capacity: 27800 Btuh 115% of load SHR: 75% <br /> • . • <br /> Design Conditions <br /> Outdoor design DB: 41.0°F Heat loss: 18729 Btuh Entering coil DB: 66.8°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Pertormance Data at Actual Design Conditions <br /> Equipment type: Elec strip <br /> Manufacturer: Model: , <br /> Actual airflow: 261 cfm <br /> Output capacity: 8.0 kW 146% of load Temp. rise: 96 °F <br /> I <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> c wri htsoft' 2015-Nov-1913:57:13 <br /> r 9 Right-Suite�Universal 2015 15.0.21 RSU07440 Page 1 <br /> �...le\R1115466-Butterfield�R1115486 Unit 6-i.rup Calc=MJ8 Building Front faces: N <br />
The URL can be used to link to this page
Your browser does not support the video tag.