: .�.. 9 � Pro ect Summar Job: R1115486 <br /> WI'1 �'1tS0� � � Date: 11-17-15 <br /> Entire House By: JND <br />' Bahr's Propane Gas 8�AC Inc <br /> 4441 Allen Rd,Zephyrhills,FL33541 Phane:813-782-5013 <br /> � • s • <br /> For: Butte�eld Quadplex Unit 6-1 <br /> 4408 Court St, Zephyrhills, FL 33542 <br /> Notes: Load Calculation was obtained from an on-site inspection. <br /> ! - • • • <br /> Weather: Lakeland Co(S), FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 41 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 29 °F Design TD 16 °F <br /> Daily range M <br /> Relative humidity 50 % <br /> Moisture difference 47 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 15350 Btuh Structure 13615 Btuh <br /> Ducts 3379 Btuh Ducts 5710 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 1416 Btuh <br /> Piping 0 Btuh I <br /> Equipment load 18729 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Inflltl'atlon Equipment sensible load 20741 Btuh <br />' Method simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br />� Fireplaces 0 Structure 2200 Btuh <br /> Ducts 1274 Btuh <br /> Heating Cooling Central vent (0 cfm) 0 Btuh <br /> Area(ftZ 1435 1435 Equipment latent load 3474 Btuh <br /> Volume ft') 11480 11480 <br /> Air changes/hour 0.45 0.23 Equipment total load 24216 Btuh <br /> Equiv.AVF (cfm) 86 44 Req. total capacity at 0.75 SHR 2.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Make Tem star or E v. <br /> Trade p q <br /> Trade TEMPSTAR <br /> Model Cond N4A330A(G)KC* <br /> AHRI ref Coil FXM4X30*'`A'` <br /> AHRI ref 3692289 <br /> Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER <br /> Heating input 8.0 kW Sensible cooling 20850 Btuh <br /> i� Heating output 27297 Btuh Latent cooling 6950 Btuh <br /> Temperature rise 96 °F Total cooling 27800 Btuh <br /> Actual air flow 261 cfm Actual air flow 927 cfm <br /> Air flow factor 0.014 cfm/Btuh Air flow factor 0.048 cfm/Btuh <br /> Static pressure 0.50 in H20 Static pressure 0.50 in H20 <br /> Space thermostat Load sensible heat ratio 0.86 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �, <br /> 201�rNov-�9 13:57•13 <br /> �. "�"' wrightsoftY Right-Suite�Universal 2015 15.0.21 RSU07440 Page 1 <br /> ��...le\R1115486-Buttertield\R'1115466 Unit Cr�.rup Calc=MJB Building Front faces: N <br />