Laserfiche WebLink
� Pro ect Summar Job: R7115486 <br /> ` �' wrightsoft � y Date: 11-17-15 <br /> Entire House By: JND , <br />� Bahr's Propane Gas �AC Inc <br />' 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 <br /> � � • • <br /> For: Butterfield Quadplex Unit 6-1 <br /> 4408 Court St, Zephyrhills, FL 33542 <br /> Notes: Load Calculation was obtained from an on-site inspection. <br /> � - • • • <br /> Weather: Lakeland Co S ,IFL, US <br /> � ) <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 41 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 29 °F Design TD 16 °F <br /> Daily range M <br /> ' Relative humidity 50 % <br /> Moisture difference 47 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 15350 Btuh Structure 13615 Btuh <br />� Ducts 3379 Btuh Ducts 5710 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br />' Humidification 0 Btuh Blower 1416 Btuh <br /> Piping 0 Btuh � <br /> Equipment load 18729 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Inflltl'ation Equipment sensible load 20741 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2200 Btuh <br /> Ducts 1274 Btuh <br /> Heating Cooling Central vent (0 cfm) 0 Btuh <br /> Area(ftz 1435 1435 Equipment latent load 3474 Btuh <br /> Volume�ft') 11480 11480 <br /> Air changes/hour 0.45 0.23 Equipment total load 24216 Btuh <br /> Equiv.AVF(cfm) 86 44 Req. total capacity at 0.75 SHR 2.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Make Tempstar or Eqv. <br /> Trade Trade TEMPSTAR <br /> Model Cond N4A330A(G)KC'` <br /> AHRI ref Coil FXM4X30'"`A* <br /> AHRI ref 3692289 <br /> Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER <br /> Heating input 8.0 kW Sensible cooling 20850 Btuh <br /> Heating output 27297 Btuh Latent cooling 6950 Btuh <br /> Temperature rise 96 °F Total cooling 27800 Btuh <br /> Actual air flow 261 cfm Actual air flow 927 cfm <br /> Air flow factor 0.014 cfm/Btuh Air flow factor 0.048 cfm/Btuh <br /> Static pressure 0.50 in H20 Static pressure 0.50 in H20 <br /> Space thermostat Load sensible heat ratio 0.86 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ^�C Wt'1 htsoft` 2015�Nov-19 13:57:13 <br /> g Right-Suite�Universal 2D15 15.0.21 RSU07440 Page 1 <br /> ��...le\R1115486-Butterfield5R1115486 Unit E1.rup Calc=MJB Building Frant(aces: N <br /> — - � <br />