Laserfiche WebLink
I <br /> I <br /> I _ <br />� I � � j � �' � ■ <br /> .y ; �;: y � , <br />� ri , , . <br /> 0 I , ' <br /> � • <br /> � <br /> � September 28, 1989 <br /> the <br /> edge oroup Fire Chief William T. Fenton <br /> Fire Departrnent <br /> p � City of Zephyrhills ' <br /> ' 38410 6th Avenue <br /> j Zephyrhills, FL 34248 <br /> arch�tects <br /> des�gners� Re: East Pasco Medical Center <br /> I O.B, and Ca�h. Tab. Adciicit�r. <br /> consuftants <br /> p I a n n e r s� Dear Chief Fenton: <br /> i n t e r i o r s �r. Ken Griff in, the Genera 1 Contrac tor for tnis pro j ec t, has <br /> � relayed several questions and comments to our office, based on <br /> 4448UNKERROAD cor.versations he has had recently with you. Thi� letter will <br /> WESTPALMBEACH atr.empt t0 answer the questions SS W0 understand them; �alease <br /> FL 33405-369i call if you need further infoimation. ' <br /> 407 585-9307 <br /> 1. ues tion - Are corridor wa 11 s 1-hour ra ted, requirino 100 <br /> square inch maximum duct penetrations, or dampers? <br /> Answer - Corridor walls are NOT 1-hour rated, per NFPA-101, <br /> PRINCIPAL , Chapter 12-3.6.1, Exception No. 1. This building is fully <br /> Donald R.Edge.A.IA.I <br />�i , fire sprinklered. Corridor walls in the area of this work <br /> � are being taken up tight to the deck above. �%�SG s�� 1��-�/ /�.� <br /> ARCHITECTS i <br /> Joe A.Rainwater,A.I.A. <br /> _ f 2• Question - Are we, as part of this pro.ject, going to have <br /> BUSINESSDEV. . th� existing corrid�or walls throughout this entire smoke <br /> GeorgeF Sauers � compartment 2A-1 extended up to the deck above? <br /> � <br /> secaeTaar � Answer - No. Existing areas not a part of this work are <br /> w'"'�`ed"'."e""edY ', not being modified. However, we have called for the <br /> ! existino walls which form the "dividing line" between the <br /> ' new work and the existing areas to be extended up tight to <br /> the deck. Notes describing this requirement are on the <br /> Floor Plan A4-1, and Reflected Ceiling Plan A4-2, at the <br /> , affected areas. - <br /> 3. uestion - Should the new cross-corridor doors all have <br /> electro-magnetic hold-opens? <br /> Answer - No. These doors are control doors only, they are <br /> not a part of the fire or smoke compartmentation system. <br /> FAX NO a07 585•9628 <br /> il . <br /> � He who builds according to evsry man's advice will have a crooked house Danish proverb <br /> 1 <br /> ' ------- -- - --- - -- -- r- <br />