My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6606 STADIUM DR (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6606 STADIUM DR (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2017 11:05:05 AM
Creation date
5/2/2017 10:57:54 AM
Metadata
Fields
Template:
Building Plans
Street #
6606 STADIUM DR
Location
STADIUM DR
Contractor
RONALD E HUFF
Building Plans - Permit #
DIALYSIS CENTER
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I1 <br /> I <br /> � <br /> I BASIC MECHANICAL REQUIREMENTS <br /> ' SECTION 15010 <br /> � ) . <br /> i <br /> � <br /> �C. Erec#ion drawings shall consist of scale drawings of the work inciuding foundatians in <br /> i plan and elevation. These drawings shall shaw clearances between units and relation <br /> � of equipment ta space assigned. Make erection drawings when requested by #he <br /> � Architect to supplement his diagrammatic drawings. <br /> ! <br /> � D. Narmal(y, with the exceptian of drawings for ductwork, erection drawings are required <br /> ionly in mechanical equipment rooms and the congested areas. The drawings sha!! also <br /> , shaw the work of all ofher trades in the immediate vicinity of such areas. Ducfinrork <br /> , � drawings are required throughout and shall be a minimum of 1/4"scale. Drawing sheets <br /> ; ' j shall be of the same size as the contract set sheets. They shall shaw wa(I partitions, <br /> , <br /> � lights, room numbers and match lines with drawing references. <br /> E. The duc#work(ayout sha�l show all apparatus such as diffusers, registers, grilles, turning <br /> � vanes, splitter dampers, volume dampers, fire and smoke dampers, duct and ceiling <br /> ' � access panels (where required}, acousticai insulatian, duct sizes and bottom elevations <br /> � of each duct. <br /> , <br /> i <br /> �I. These drawings sl�all became part af the �nal as-built recards. Coordinate with <br /> � i strucEural and architectural drawings for available ceiling ctearance. <br /> G. Submit samples requested for appfavai. The sample shal! be praperiy taggecf and.will <br /> iremain in the Architecf's possession untif final acceptance-af the work. - <br /> I. The stamp af approval daes not relieve the confractar of his responsibi(ity to comply with <br /> 1 all requirements of this specification. <br /> 1.11 SUBMITTAL REQUIREMENTS <br /> , i <br /> � i. Submittal data is required for each Division 15 sectian. <br /> � <br /> i B. Submittals for this secfion: <br /> �' � 1. Firm qualifications for this project. <br /> ; � 2. Foreman's resume and experience for this project. <br /> ! 3. List of subcontractors. <br /> 4. Schedute of vaEues. <br /> 5. Mechanical system identification. i <br /> � <br /> t <br /> C. A(( data shali be submitted to the Engineer at one time; partial submittals will nat be <br /> accepted. Submit in individual vinyl-cavered 3-ring binders. The front �cover of the <br /> binder shall cantain the projecf name and the Brian Cumming & Associates, tnc. job <br /> number from the drawings. Index each section using the format from the Project <br /> Specifica#ians. Each section of the submittal sha11 begin with a "Submittal Id�ntificatian <br /> Sheet" (last page of this specification section) with a complete list of all items in that <br /> section. Failure to follow this procedure shall result in rejection of the submittaf by the <br /> Engineer. This list sha(I also contain the following information: <br /> � 1. Model numbers and summary descriptions. <br /> 2. The number of pages submitted for each item. <br /> 3. Space for Engineer's review stamp for each item. <br /> � 4. Names of Project, Contractor,Sub-Contractors and Suppliers of Equipment. <br /> The submittal shalf be farmatted in this manner in order#o facElitate timel review b the <br /> Y Y <br /> Engineer. Engineer shall review submittal data na more than two times. Additional <br /> submittal review time shall be paid by Contractor under the base bid at a minimum rate <br /> � af$65A0/hour. <br /> i <br /> {s�oos-o�o�s�} s�o�a-� <br /> �s7oas-u4ci4yr,� •__.- - <br /> I ' <br /> � � <br /> � <br /> __ I � <br /> I <br /> 1 <br /> 'D, See Section 15990 for responsibilities of inechanical contractor prior to test and <br /> i i �}r'3�r`i11G£.'. <br /> i <br /> i � <br /> (9700&040497) ���1�-�� <br /> ( <br /> � � <br /> � <br /> � ' <br /> i <br /> i <br /> I <br /> i <br /> � <br /> 1 <br />