My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37343 LAUREL HAMMOCK DR
Zephyrhills
>
Building Department
>
Building Plans
>
37343 LAUREL HAMMOCK DR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2017 10:21:11 AM
Creation date
5/15/2017 10:18:13 AM
Metadata
Fields
Template:
Building Plans
Street #
37343 LAUREL HAMMOCK DR
Location
OAK RUN
Contractor
RYMAN CONSTRUCTION
Building Plans - Permit #
0512
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> Branch circuits for lighting and for appliances,including motor-operated appliances, shall be provided to supply , <br /> the loads computed in accordance with Section 220-3. In addition,branch circuits shall be provi'ded for specific <br /> loads not covered by Section 220-3 where required elsewhere in this Code and for dwelling unit loads-as <br /> specified in(c).i��� ' ; Y <br /> (a)Number of Branch Cnrcuits. The minimum number of branch circuits shall be determined from the total <br /> computed load and the size or rating of the circuits used. In all installations,the number of circuits sha11 be <br /> sufficient to supply the load served. In no case sha11 the load on any circuit exceed the maximum specified by <br /> Section 220-4. � <br /> � <br /> (b) I,oad Evenly Proportioned Among Branch CYrcuits. Where the load is computed on a j <br /> volt-amperes/square foot(0.093 m2) basis,the wiring system up to and including the branch-circiait <br /> panelboard(s) shall be provided to serve not less than the calculated load. This load.shall be evenl�y proportioned <br /> among multioutlet branch circuits within the panelboard(s). Branch-circuit overcurrent devices a.nd circuits need <br /> only be installed to serve the connected load. i ' <br /> (c)Dwelling Units. I � <br /> (1) Small-Appliance�ranch Circuits. In addition to the number of branch circuits required by I�ther parts of <br /> this section,two or more 20-ampere small-appliance branch circuits sha11 be provided for all rece�tacle outlets <br /> specified by Section 210-52(b). � <br /> � <br /> (B)�,aundry�ranch Circuits. In addition to the number of branch circuits required by other parts of this <br /> section, at least one additional 20-ampere branch circuit shall be provided to supply the laundry r i�epta.cle <br /> outlet(s)required by Section 210-52(fl. This circuit shall have no other outlets. �, <br /> (3) Bathroom Branch Careuits. In addition to the number of branch circuits required by other palrts of this <br /> section, at least one 20-ampere branch circuit sha11 be provided to supply the bathroom receptaclel outlet(s). : <br /> Such circuits shall have no other outlets. ' <br /> Exception: Where the 20-arnpere circuit supplies a single bathroom, outlets for other equipmen�t within the y <br /> same bathroom shall be pe�mitted to be supplied in accordance with Section 210-23(a). � <br /> FPN: See Examples D 1(a),D1(b),D2(b),and D4(a)in Appendix D. �', <br /> I <br /> ��210-52. IDwelling�7nit iteceptacle Outlets ' <br /> I <br /> Receptacle outlets required by this section sha11 be in addition to any receptacle that is part of a lin�hting fixture , <br /> or appliance, located within cabinets or cupboards, or located more than 51/z ft(1.68 m) above the�floor. <br /> Permanently installed elecixic baseboard heaters equipped with factory-installed receptacle outlets lor outlets • <br /> provided as a separate assembly by the manufacturer sha11 be permitted as the required outlet or ou.tlets for the <br /> wall space utilized by such permanently installed heaters. Such receptacle outlets shall not be co��.ected to the <br /> heater circuits. i <br /> � <br /> FPN:Listed baseboard heaters include instructions that may not permit their installation below receptacle outlets.�ic�+`"� ` <br /> i' <br /> (a) Genea�al Provisions. In every kitchen, family room, dining room, living room,parlor,library, d.en, sunroom, <br /> bedroom,recreation room, or similar room or area of dwelling units, receptacle outlets shall be ins�:alled in � <br /> accordance with the general provisions specified in(1)through(3). <br /> (1) Spacing. Receptacles shall be installed so that no point along the floor line in any wall space is more than 6 <br /> ft (1.83 m), measured horizontally, from an outlet in that space. Receptacle outlets shall, insofar as�racticable, <br /> be spaced equal distances apart.,����u �I � <br /> (B)�Vall Space. As used in this section, a wa11 space shall include the following: I <br /> � <br /> a. Any space 2 ft (610 mm) or more in width(including space measured around corners) and un�broken along <br /> � . <br /> i � <br /> � <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.