My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37343 LAUREL HAMMOCK DR
Zephyrhills
>
Building Department
>
Building Plans
>
37343 LAUREL HAMMOCK DR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2017 10:21:11 AM
Creation date
5/15/2017 10:18:13 AM
Metadata
Fields
Template:
Building Plans
Street #
37343 LAUREL HAMMOCK DR
Location
OAK RUN
Contractor
RYMAN CONSTRUCTION
Building Plans - Permit #
0512
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> � <br /> the floor�line by doo�ways, fireplaces,;and similar openi.ngs <br /> - ' I <br /> b. The space occupied by fixed panels in exterior walls, excluding sliding panels <br /> � c. Th'e space afforded by fixed room dividers such as freestanding bar-type counters or railings�;ca;�„��e�y� <br /> (3) Floor Receptaclea. Receptacle outlets in floors shall not be counted as part of the required number of <br /> receptacie outlets unl ess located within 18 in. (457 mm) of the wall. <br /> (b) Sma71 Appliances.,c�,�;�a,y <br /> 1. Inithe kitchen,pantry, breakfast room, di.ning room, or similar area of a dwelling unit,the two or more <br /> 20-ampere small-ap �liance branch circuits required by Section 210-11(c)(1) sha11 serve all receptacle outlets <br /> covered by Sections 210-52(a) and(c) and receptacle outlets for refrigeration equipment. <br /> Exception No. 1: I i addition to the required�eceptacles specified by Section 210-52, switched receptacles <br /> . supp lie d,f rom a genera l purpose branc h carcui t as de f ine d in Section 2 1 0-7 0(a)(1), Exception No. 1, s ha l l be <br /> permitted. (ca�� I <br /> = Exception No. 2: �e receptacle outlet for�ef�ige�ation equipment shall be permitted to be su�plied from an <br /> individu'al branch ci��cuit rated 1 S ampe�es or greate�. �c�;,,���a�;� <br /> ; <br /> 2. The two or mi re small-appliance branch circuits specified in(b)(1) shall have no other outlets. <br /> � I <br /> Exception No. 1. f1 receptacle installed solely fo�the electrical supply to and support of an elect�-ic clock in <br /> any of the roonzs specified above. <br /> Exception No. 2: Receptacles installed to provide power for supplemental equipment and lighting on <br /> gas-fired Yanges, o lens, or counter-mounted cooking units. ,Gc� <br /> - 3. Receptacles 'iristalled in a kitchen to serve countertop surfaces sha11 be supplied by not less than two <br /> � small-appliance branch circuits, either or both of which sha11 also be permitted to supply receptacle outlets in <br /> ''� the same kitchen an�d in other rooms specified in Section 210-52(b)(1). Additional small-appliance branch <br /> circuits!sha11 be perinitted to supply receptacle outlets in the kitchen and other rooms specified in Section <br /> 210-52(b)(1).No small-appliance branch circuit shall serve more than one kitchen. <br /> (c) Countertops. In�kitchens and dining rooms of dwelling units, receptacle outlets for counter spaces shall be <br /> installed in accord i�ce with(1)through(5). <br /> , (1)Wall Counter Spaces.A receptacle outlet shall be installed at each wa11 counter space that is 12 in. (305 <br /> mm) ori wider. Receptacle outlets shall be installed so that no point along the wall line is more than 24 in. (610 <br /> mm),measured homlzontally from a receptacle outlet in that space. <br /> ' i <br /> (2)Island Counter�paces.At least one receptacle outlet shall be installed at each island counter space with a <br /> long dimension of 24 in. (610 mm) or greater and a short dimension of 12 in. (305 mm) or greater. <br /> (3) Pe�insular Counter Spaces. At least one receptacle outlet shall be installed at each peninsular counter <br /> - space�vith a long dimension of 24 in. (610 mm) or greater and a short di.mension of 12 in. (305 mm) or greater. <br /> A peninsular countertop is measured from the connecting edge. <br /> ' (4) Separate Spaci�s. Countertop spaces separated by range tops, refrigerators, or sinks shall be considered as <br /> separate counterto � ispaces in applying the requirements of(1), (2), and (3). <br /> (5) Receptacle O�tlet I,ocation. Rece tacle outlets sha11 be located above but not more than 18 in. 458 <br /> p , ( mm) <br /> above the countertop. Receptacle outlets shall not be installed in a face-up position in the work surfaces or <br /> counteitops.Receptacle outlets rendered not readily accessible by appliances fastened in place or appliances <br /> � <br /> occupying dedicated space shall not be considered as these requ.ired outlets. ;'�,,;�;�a:� <br /> _ ' i <br /> Exception: To cornply with the conditions as specified in (a) or (b), receptacle outlets shall be permitted to be <br /> . ; <br /> �'{ ' i <br /> � I <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.