Laserfiche WebLink
� <br /> . , <br /> ��� 1 t�s�������� �� ��aysnc�� ��aga�g�. Overcurrent devices sha11 be located where they will not be exposed to <br /> physical damage. �I - <br /> FPN: See Section 110-11,Deteriorating Agents. <br /> i <br /> ��� 1'��t iaa �acan��y ��'��sa9��g�a�tnb��l��t�r��i. Overcurrent devices sha11 not be located in the vicinity of <br /> easily ignitible mat'I rial, such as in clothes closets. :�� <br /> (e�l�To�I,�cat�� gai��t�n�o�aaa�. In dwelling units and guest rooms of hotels and motels, overcurrent devices, <br /> ' other than supplementary overcurrent protection, shall not be located in bathrooms as defined in Article 100. <br /> �250-50. �round�ng Elecga��a$e S�stea� <br /> � <br /> If available on the premises at each building or structure served, each item (a) through (d), and any made � <br /> electrodes in accordance with Sections 250-52(c) and (d), shall be bonded together to form the grounding <br /> electrode system. The bonding jumper(s) shall be installed in accordance with Sections 250-64(a), (b), and (e), <br /> shall be'sized in accordance with Section 250-66, and shall be connected in the manner specified in Section <br /> 250-70., � <br /> An uns �liced oundin electrode conductor shall be ermitted to be run to an convenient oundin electrode <br /> P �' g P Y �' g <br />� available in the ��n ' r � <br /> grou dmg electrode system o to one or more grounding electrode(s) individually. It shall be <br /> sized for the lar est I oundin electrode conductor re uired amon all the electrodes connected to it. :�on.n.er��. � <br /> g �' g q g ��,�.� <br /> The grounding electrode conductor sha11 be unspliced or spliced by means of irreversible compression-type <br /> connectors listed fori the puipose or by the exothernuc welding process. <br />', I . <br /> Interior metal water i in located more than 5 ft 1.52 m from the oin f n r <br />, p p g ( ) p t o e t ance to the buildin shall not be <br /> g <br /> used as a part of the�grounding electrode system or as a conductor to interconnect electrodes that are part of the <br /> groundirig electrode system. <br /> i <br /> Exception:In indarstrial and commercial buildings where conditions of maintenance and supervision ensure <br /> that only qualified pe�•sons will se�vice the installation and the entire length of the interior metal water pipe that <br /> is being zrsed for the 'I onductor is exposed. °;���-�ra��:y� <br /> FPN: See Sections 5i7-8 and 547-9 for special grounding and bonding requirements for agricultural buildings. <br /> �a}1°d��tafl i7nclea��round�Ja����ipe. A metal underground water pipe in direct contact with the earth for 10 ft <br /> (3.05 m) or more (including any metal well casing effectively bonded to the pipe) and electrically continuous (or <br /> made electrically continuous by bonding around insulating joints or sections or insulating pipe) to the points of , <br /> connection of the grounding electrode conductor and the bonding conductors. ;�a���a�� <br /> {l� f;��atnnuiiy. Contil'nuity of the grounding path or the bonding connection to interior piping shall not rely on <br /> water meters or filtenng devices and similar equipment. <br /> 2 S�a ���ane�nta� �le;ctr�de�8e uareai. A metal under round water i e shall be su lemented b an additional <br /> � � �� � g P P pP Y <br /> electrode of a type specified in Sections 250-50 or 250-52. Where the supplemental electrode is a made electrode <br /> of the rod,�pipe, or plate type, it shall comply with Section 250-56. The supplemental electrode sha11 be permitted <br /> to be bond'ed to the gr�ounding electrode conductor, the grounded service-entrance conductor, the nonflexible <br /> grounded service raceway, or any grounded service enclosure. ':�� <br /> Exception: The suppl emental elect�ode shall be peYmitted to be bonded to the interior metal water piping at <br /> m <br /> any convenient point a �covered in Section 250-50, Exception. <br /> Where the supplemental electrode is a made electrode as in Section 250-52(c) or (cl), that portion of the bonding <br /> jumper that is the sole connection to the supplemental grounding electrode shall not be required to be larger than <br /> No. 6 copper wire or No 4 aluminum wire. ;��,��,�ga�y� <br /> �b) l�e�ad�raaYae �f the�aanic�aa�� or �tra�c��ar�. The metal frame of the building or structure, where effectively . <br /> � <br />