My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39128 OLD MILL LN
Zephyrhills
>
Building Department
>
Building Plans
>
39128 OLD MILL LN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2017 11:10:36 AM
Creation date
5/15/2017 11:07:38 AM
Metadata
Fields
Template:
Building Plans
Street #
39128 OLD MILL LN
Contractor
TENBRINK AND ASSOCIATES
Building Plans - Permit #
0578
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� grounded. <br /> �e� �anc�•���-E�aca�ed ������ode. An.electrode encased by at least 2 in. (50.8 mm) of concrete, loc;ated within <br /> and near the bQttom of.a concrete foundation or footing that is in direct contact with the earth, consisting of at <br /> least 20 ft (6.1 m) of one or more bare or zinc galvanized or other electrically conductive coated st�el reinforcing <br /> bars or rods of not less than '/2-in. (12.7-mm) diameter, or consisting of at least 20 ft (6.1 m) of bare copper <br /> conductor not smaller than No. 4. Reinforcing bars shall be pernutted to be bonded together by the usual steel tie <br /> wires or other effective means. ���r�a�,;� - <br /> (d� �rouand Raaag. A ground ring encircling the building or structure, in direct contact with the eaxth at a depth <br /> below the earth's surface of not less than 2'/z ft (762 mm), consisting of at least 20 ft (6.1 m) of bare copper <br /> conductor not smaller than No. 2. ;��,,,�;�a�y� <br /> ����, ���0-57. ktecept�cles gn Damp ar�et l�.ocataans _ . <br /> �a� �aa�ap �.�.c��ioa�s. A receptacle installed outdoors in a location protected from the weather or in other damp <br /> locations shall have an enclosure for the receptacle that is weatherproof when the receptacle is co`�ered <br /> (attachment plug cap not inserted and receptacle covers closed). <br /> An installation suitable for wet locations shall also be considered suitable for damp locations. <br /> A receptacle shall be considered to be in a location protected from the weather where located und.er roofed open <br /> porches, canopies, marquees, and the like, and will not be subjected to a beating rain or water run.off. <br /> {b� �%�Iet I,�catio�as. <br /> 1. A receptacle installed in a wet location where the product intended to be plugged into it is�Z��t attended <br />' while in use (e.g., sprinkler system controllers, landscape lighting, holiday lights, etc.) shall have ��ri enclosure <br /> that is weatherproof with the attachment plug cap inserted or removed. ;��TM��a��:� � � <br /> 2. A receptacle installed in a wet location where the product intended to be plugged into it wi_l�be attended <br /> while in use (e.g., portable tools, etc.) shall have an enclosure that is weatherproof when the attachment plug cap <br /> is removed. :����a�y� <br /> (�) �at�tu&r �nd 5��av�� �pace. A receptacle shall not be installed within a bathtub or shower s.pace. ����a.y� <br /> ��➢) Prat�c�ioaa fv��+'loo�-�ecept��les. Standpipes of floor receptacles shall allow floor-cleaning equipment to be <br /> operated without damage to receptacles. <br /> (e� ��ush IVY+�uaa$ang��it�a �'ace���at�. The enclosure for a receptacle installed in an outlet box flush-mounted on <br /> a wa11 surface sha11 be made weatherproof by means of a weatherproof faceplate assembly that provides a <br /> watertight connection between the plate and the wall surface. <br /> (� �st�ll�tioaa. A receptacle outlet installed outdoors sha11 be located so that water accumulati��n is not likely to <br /> touch the outlet cover or plate. :c�,�,��a�y� <br /> CA�O 3�6.�. Smoke�letee�ors required: <br /> Smoke detectors shall be installed in each sleeping room, outside of each separate sleeping area in the <br /> , immediate vicinity of the bedrooms. <br /> CA�O�16.2 Power source: <br /> required smoke detectors shall receive their primary power from the building wiring when such wiring is <br /> served form a commercial source, and when primary power is interrupted, shall receive power frc�m a <br /> battery. <br />
The URL can be used to link to this page
Your browser does not support the video tag.