Description
DIAGNOSTIC SHELL ADDITION
Owner
EAST PASCO MEDICAL CENTER
Building Plans - Permit #
0090B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`'�` ^s , I ,i ; _ .,---� _ <br /> i I ; <br /> � � I <br /> , ; <br />� REVISION NO. 5 <br />� �OVEMBER 22, 2000 <br /> i <br /> DIAGNOSTIC'S ADDITION-PHASE I <br /> EAST PASC�O�MEDICAL CENTER - _ � . <br /> ZEPHYRHIL��S,FLORIDA _ � <br />� ESa JOB NOi 99087.00 <br /> EARL SWENSSON ASSOCIATES <br /> �100 WEST END AVENUE, SIJITE 1200 ° <br /> i ASHVILLE,TENNESSEE 37203 <br /> i � <br /> 1'his Revision forms a part of the Contract Documents and modifies the original Bidding Documents, <br /> dated July 28,�2000, as outlined here in addition to being shown on the drawings as Delta 5,dated ' <br /> I ovember 22��2000: <br /> I I / <br /> CHANGES TO THE SPEC]FICATIONS <br /> il " <br /> 1. Refe'r to the Speci�cation Section 08100-Hollow Metal Doors and Frames and insert the <br /> following: <br /> i • <br /> 2.7 ' , Performance: ' <br /> ' <br /> A. Hollow metal doors and frames shall be tested to ASTM E1886-97 Standard <br /> ' Test Method for performance of exterior windows,curtainwalls, doors and the <br /> � storm shutters impacted by missiles and exposed to cyclic pressure differentials. <br /> B. Hollow metal doors and frames shall meet the debris impact requirements in the <br /> _ South Florida Building Code(SFBC,Reference 1.3). Provisions of SBCC I Test <br /> Standazd for determining impact resistance for wind-borne debris,SSTD 12-97 <br /> i <br /> (Reference 1.4). <br /> 2. Refer�to Speci�cation Section 08800-Glass and Glazing and refer to Part 2-Products; 2.1 <br /> Glass and change the item G to read as follows: <br /> "G. � Clear Laminated Glass: G1assLam(9/16"overall) laminated by Custom Glass of Fort <br /> Lauderdale(954/491-7862). <br /> 3. Referl to the Specification Section 15910-Sheet Metal Accessories and refer to item"L" and add I <br /> the following: I <br /> �� <br /> 12. Louvers shall be tested to ASTM E1886-97 Standazd Test Method for performance of ' � <br /> exterior windows,curtainwalls,doors and storm shutters impacted by missiles and <br /> exposed to cyclic pressure differentials. - ' <br /> 13. ; Louvers systems shall meet the debris impact requirements in the South Florida Building <br /> Code(SFBC, Reference 1.3). Provisions of SBCC I Test Standard for determining <br /> impact resistance for wind-bome debris,SSTD 12-97 (Reference 1.4). <br /> I <br /> I ; <br /> � � <br /> REVISION NO. 5 PAGE 1 JOB NO. 99087.00 <br />�,\ � I <br /> I I . <br />
The URL can be used to link to this page
Your browser does not support the video tag.