My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-16850
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-16850
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2020 1:37:31 PM
Creation date
7/12/2017 1:36:54 PM
Metadata
Fields
Template:
Building Department
Company Name
SUMMERSET APARTMENTS
Building Department - Doc Type
Permit
Permit #
16-16850
Building Department - Name
SUMMERSET APARTMENTS
Address
6659 FORT KING RD
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
369
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
__ _ _____ � l <br /> �,, � • FORM 2-K � <br /> .ryutomai�c 5prir►kler Sysfiems <br />� Co�.�ractar's Mat��rial and Test <br /> C�ertificate for Underground Piping <br /> � <br /> Date:r � r/ Property ame: � <br /> P�operEy Address: � - � l�fr�, �'� .c f�j r <br /> Procedure <br /> lJpon�.completion af wbrk, inspection and tests shall be made by the contractar's representative and witnessed by <br /> an o ne�'s r�presentative.Ail ciefects shatl be corrected and the system (eft in service before contractor's persottnei <br /> finatl�+ ieave the jab. <br /> A certificate shall be filled out and signed by both representatives.Copies sha!! be prepared for approving authari- <br /> ties, owners,and cantractors.}t is understaod that the owner's repcesentative's signature in no way prejudices any <br /> claim�against contractor far faulty material, poor warkmanship,or•failure to camply with approving autharity's <br /> reqw�ements ar locai ordinanc�s. <br /> Plans <br /> Acce i ted bY[�pP�'aving authority's nameCs)3 <br /> Address <br /> R <br /> Installation conforms to accepted plans? Yes � Na <br /> Egui �ment used is ap�roved? Yes O No <br /> If no, explain deviations. <br /> Instructions <br /> Has persan in charge of fire equipment been instructed as to IQcation of controE valves <br /> and �are and maintenance of this new equiprnent? 97 Yes O IVo <br /> If no, explain. <br /> Have copies of app�opriate instructions and care and maintenance charts been left on � <br /> i premises? ❑ Yes 0 No <br /> ' If na,�explain. <br /> Coca�ion � ' <br /> . Supplies bidgs. <br /> Unde�ground Pipes and oints <br /> ' Pipe i onforms to_��� , standard. Yes ❑ No <br /> Fittings conforms to �f�- standard. �1'� ❑ NQ <br /> � if�o,�expiain. , <br /> Join� needin anchorage clamped, strapped, or blotked in accardance with <br /> ' ����� standard. '�Yes ❑ No <br /> �� If na,explain. <br /> � � <br /> i Test Pescription <br /> FLUSN!lVG:Flow the reguired rate until wate�is clear as indicated by na coElectic�n csf foreign materiat in burIap <br /> bags at outletr sucfi� as hydrants and blaw offs. Ftush at flows not less than 400 gpm(1 S14 Umin)for 4in.(102-mrn} <br /> pipe,�600 gpm (2271 L/min)far 5-in.(127-rnm) pipe, 750 gpm (2839 L/min)for 6-in. (152-mm)pipe, 100D gpm <br /> {3785 l.Jrr�in�for 8-in. {2P3-mm}pipe, 15p0 gpm{5t78 �Jmin)for 10-in.{2S4-mm}pipe and 200Q g�m(757f? <br /> Llmi�)for 12-in. (305-mm}pipe.When supply cannot produce stipulated flow rates, abtain maximum available. <br /> PAGE 1 af 2 <br /> Copyright�12000 National Fire Protection Association <br /> I . .. . ..._ - �- - <br /> - , , <br /> i ---� <br />
The URL can be used to link to this page
Your browser does not support the video tag.