I
<br /> �
<br /> � Florida Building Code Online Page 2 of 7
<br /> I
<br /> i
<br />�� � �
<br /> � � Date Submitted 03/19/2015 �
<br /> I Date Validated 06/12/2015 ;
<br /> Date Pending FBC Approval
<br /> Date Approved 06/21/2015 i
<br /> I �
<br /> Summary of Products
<br /> I Go to Page � '� � �i) Page 7/8� 9�
<br /> � FL# Model,Number or Name Description I
<br /> 15279.121 121 W6-18 PAN-2F443: G45,GS4, Gallery/Artistry/Expressions: Steel Pan(min.24 ga.)16'4" �
<br /> i GD4S,GR4S,G4SV,GS4V,GD4SV, to 18'2"wide WINDCODEp W6 Garage Door
<br /> i GR4SV,E4S,ED4S,E4SV,ED4SV,
<br /> , SS4,AR4S,SS4V,AR4SV
<br /> Limits of Use Certification Agency Certificate
<br /> Approved for use in HVHZ:No FL15279 R4 C CAC Letter with oroof of contract and oroof �
<br /> Approved for use outside HVHZ:Yes of insoection.odf �
<br /> Impact Resistant:Yes FL15279 R4 C CAC W6 Listinq Intertek.odf
<br /> Design Pressure: +37 PSF/-39 PSF Quality Assurance Contract Expiration Date
<br /> Other:Solid doors(no standard glazing)are impact- OS/21/z028
<br /> � resistant(large missile impact). Installation Instructions
<br /> FL15279 R4 II 103406-A-Rev06.odf
<br /> Verified By: Intertek Testing Services NA Inc.-
<br /> � EI�L/Warnock Hersey
<br /> I Created by Independent Third Party:
<br /> Evaluation Reports
<br /> i Created by Independent Third Party:
<br /> 15279.122 122 W6-18 PAN-2F443: G4S,GS4, Gallery/Artistry/Expressions:Steel Pan(min.24 ga.)16'4"
<br /> GD45,GR4S,G4SV,GS4V,GD45V, to 18'2"wide WINDCODEp W6 Garage Door
<br /> GR45V,E4S,ED4S,E4SV,ED4SV,
<br /> SS4,AR4S,SS4V,AR45V
<br /> � Limits of Use Certification Agency Certificate
<br /> � Approved for use in HVHZ:No FL15279 R4 C CAC Letter with oroof of contract and oroof
<br /> Approved for use outside HVHZ:Yes of insoection.odf
<br /> Impact Resistant:No FL15279 R4 C CAC W6 Listinq Intertek.pdf
<br /> Design Pressure:+37 PSF/-39 PSF Quality Assurance Contract Expiration Date
<br /> Other:The standard glazing available for this product OS/21/z028
<br /> meets the wind load requirements of the building code but Installation Instructions
<br /> ; DOES NOT meet the impact resistant requirement for FL15279 R4 II 103406-B-Rev06.odf
<br /> � windborne debris regions. Verified By: Intertek Testing Services NA Inc.-
<br />, i
<br /> ETL/Warnock Hersey
<br /> Created by Independent Third Party:
<br /> Evaluation Reports
<br />� Created by Independent Third Party: ,
<br /> 15279.1Z3 123 W4-09 DSIE-1F171: 4300, 2"Double-skin Insulated EPS(exterior skin 27 ga.min.;
<br /> 4301,4310,4400,4401, HDG, interior skin 27 ga. min.)Single-Car(up to 9'0"wide)
<br /> HDGL,HDGF,66,66G,67,67G, WINDCODEp W4 Garage Door '
<br /> 68,SP200,SF200,SE200,6Z00, ,
<br />� � 6201,6203
<br /> i
<br />� I Limits of Use Certification Agency Certificate
<br />� � Approved for use in HVHZ:No FL15279 R4 C CAC Letter with oroof of contract and oroof �
<br />� Approved for use outside HVHZ:Yes of insoection.odf
<br /> Impact Resistant:Yes FL15279 R4 C CAC W4 Lisfinq Intertek.pdf
<br /> � Design Pressure:+28 PSF/-29 PSF Quality Assurence Contract Expiration Date �
<br /> j Other:Solid doors(no glazing)or doors with optional OS/21/2028 i
<br />� ; impact-resistant glazing are Impact-resistant(large missile Installation Instructions
<br />, ; Impact). FL15279 R4 II 101652-A-Revli.odf
<br /> Verified By: Intertek Testing Services NA Inc.- �
<br /> � ETL/Warnock Hersey '
<br /> , Created by Independent Third Party: - �
<br /> I Evaluation Reports
<br /> Created by Independent Third Party: ,
<br /> I 15279.124 124 W4-16 DSIE-1F171:4300, 2"Double-skin Insulated EPS(exterior skin 27 ga.min.; �
<br /> I� � 4301,4310,4400,4401,HDG, interior skin 27 ga.min.)Double-Car(9'2"to 16'0"wide) �
<br /> � HDGL,HDGF,66,66G,67,67G, WINDCODEp W4 Garage Door ,
<br /> I 68,SP200,SF200,SE200,6200, i
<br /> 6201,6203
<br /> Limits of Use Certification Agency CertiFcate
<br /> I Approved for use in HVHZ:No FL15279 R4 C CAC Letter with oroof of contrect and oroof ,
<br /> I Approved for use outside HVHZ:Yes of insoection.pdf
<br /> Impact Resistant:Yes FL15279 R4 C CAC W4 Listinq Intertek.Ddf
<br /> Design Pressure:+25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date
<br /> Other:Solid doors(no glazing)or doors with optional OS/21/2028
<br />� impact-resistant glazing are impact-resistant(large missile Instatlation Instructions
<br /> impact). FL15279 R4 II 101481-A-Revl3.odf
<br /> Verified By: Intertek Testing Services NA Inc.-
<br /> http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yWKJZ 1 Q... 5/20/2016 ,
<br /> i I
<br />
|