' Florida Building Code Online Page 3 of 7
<br /> �
<br /> • , � ETL/Warnock Hersey ,
<br /> � Created by Independent Third Party:
<br /> Evaluation Reports
<br /> i Created by IndependentThird Party:
<br /> � 15279.125 125 W4-18 DSIE-SF171:4300, 2"Double-skin Insulated EPS(exterior skin 27 ga.min.;
<br /> 4301,4310,4400,4401,HDG, interior skin 27 ga. min.)16'2"to 18'0"wide WINDCODEp
<br /> ' HDGL,HDGF,66,66G,67,67G, W4 Garege Door
<br /> i 68,SP200,SF200,SE200,6200,
<br /> � 6201,6203
<br /> � Limits of Use ` Certification Agency Certificate
<br /> Approved for use in HVHZ:No FL15279 R4 C CAC Letter with proof of contract and oroof
<br /> � Approved for use outside HVHZ:Yes of insoection.�df
<br /> ! Impact Resistant:Yes FL15279 R4 C CAC W4 Listinq Intertek.odf
<br /> i Design Pressure:+25 PSF/-25 PSF Quality Assurance Contrect Expiration Date
<br /> Other:Solid doors(no glazing)or doors with optional OS/21/2028
<br /> impact-resistant glazing are impact-resistant(large missile Installation Instructions
<br /> impact). FL15279 R4 II 101247-A-Revl9.odf
<br /> Verified By: Intertek Testing Services NA Inc.- �
<br /> ETL/Warnock Hersey
<br /> Created by Independent Third Party:
<br /> Evaluation Reports
<br /> � Created by Independent Third Party:
<br /> �
<br /> i
<br /> 15279.126 126 W4-09 PAN-2F151: 73, 1500, Steel Pan(min.25 ga.)Single-Car(up to 9'0"wide)
<br /> � 75, 190,84A,94,76,42,48,55, WINDCODEp W4 Garage Door
<br /> � �� � 428,48B,SSS,4RST,6RST,4RSF,
<br /> , 6RSF,2RST,GDSS,GDSSV,GR5S,
<br /> GR5SV,ARSS,ARSSV,EDSS,
<br /> EDSSV
<br /> i
<br /> Limits of Use Certification Agency Certificate �
<br /> � Approved for use in HVHZ:No FL15279 R4 C CAC Letter with oroof of contract and oroof
<br /> Approved for use outside HVHZ:Yes of insoection.odf
<br /> i Impact Resistant:Yes FL15279 R4 C CAC W4 Listinq Intertek.Ddf
<br /> Design Pressure:+25 PSF/-32 PSF Quality Assurance Contract Expiration Date ,
<br /> Other:Solid doors(no glazing)or doors with optional OS/21/2028
<br /> impact-resistant glazing are impact-resistant(large missile Instaltation Instructions
<br /> impact). FL15279 R4 II 300159-A-Revl6.pdf
<br /> Verified By: Intertek Testing Services NA Inc.- ;
<br /> ETL/Warnock Hersey
<br /> Created by Independent Third Party:
<br /> Evaluation Reports
<br /> � Created by Independent Third Party: ,
<br /> 15Z79.127 127 W4-16 PAN-2F153: 73, 1500, Steel Pan(min.25 ga.)Double-Car(9'2"to 16'0"wide)
<br /> 75, 190,84A,94,42,48,55, WINDCODEp W4 Garage Door
<br /> 4RST,6RST,4RSF,6RSF,GDSS, ,
<br /> GDSSV,GRSS,GRSSV,ARSS, ,
<br /> AR5SV,EDSS,EDSSV
<br /> Limits of Use Certification Agency Certificate ,
<br /> Approved for use in HVHZ:No FL15279 R4 C CAC Letter with oroof of contract and oroof
<br /> j Approved for use outside HVHZ:Yes of ins�ection.odf �
<br /> I Impact Resistant:Yes FL15279 R4 C CAC W4 Listinq Intertek.odf
<br /> � Design Pressure:+24 PSF/-24.5 PSF Quality Assurance Contract Expiration Date
<br /> � Other:Solid doors(no glazing)or doors with optional OS/21/2028
<br /> � impact-resistant glazing are impact-resistant(large missile Installation Instructions �
<br /> i impact). - FL15279 R4 II 101711-A=RevlS.odf
<br /> i Verified By:Intertek Testing Services NA Inc.-
<br /> I ETL/Warnock Hersey
<br /> Created by Independent Third Party: '
<br /> Evaluation Reports '
<br /> ' Created by Independent Third Party:
<br /> I '
<br /> I �
<br /> � 15279.128 128 W4-18 PAN-2F153: 73, 1500, Steel Pan(min.25 ga.)16'2"to 18'0"wide WINDCODEO �
<br /> I
<br /> i 75, 190,84A,94,42,48,55,42B, W4 Garege Door
<br /> � 48B,555,4RST,6RST,4RSF,
<br /> � 6RSF,GDSS,GDSSV,GRSS, i
<br /> � GRSSV,AR55,ARSSV,EDSS, �
<br /> � EDSSV i
<br /> ( Limits of Use Certification Agency Certificate �
<br /> Approved for use in HVH2:No FL15279 R4 C CAC Letter with oroof of contract and oroof ;
<br /> � Approved for use outside HVHZ:Yes of inspection.odf
<br /> Impact Resistant:Yes FL15279 R4 C CAC W4 Listinq Intertek.odf
<br /> Design Pressure:+25 PSF/-25 PSF Quality Assurance Contract Expiration Date
<br /> � Other:Solid doors(no glazing)or doors with optional O5/21/2028
<br /> I impact-resistant glazing are impact-resistant(large missile Installation Instructions
<br /> impact). FL15279 R4 II 101312-A-Revl4.odf
<br /> I Verified By: Intertek Testing Services NA Inc.-
<br /> ETL/Wamock Hersey
<br /> Created by Independent Third Party:
<br /> http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZI Q... 5/20/2016
<br /> I
<br />
|