My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17936
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17936
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2017 8:55:48 AM
Creation date
7/20/2017 8:55:46 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
16-17936
Building Department - Name
DUNE FL LAND I SUB LLC C/O HAWK
Address
6378 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-201� <br /> I MAN[�ATORY REQUIREMENTS - (Continued) <br /> � �R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. <br /> ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) <br /> or b��elow 55°F(13°C)shall be insulated to a minimum of R-3., -� <br /> R403.3.1 Protection of piping insulation. <br /> � R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily <br /> acc�essible manual switch that can tum off the hot-water circulating pump when the system is not in use. <br /> � R403.4.3 Neat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have <br /> hea traps installed on both the inlets and outlets. Extemal heat traps shall consist of either a commercially available heat trap or a <br /> do � ward and upward bend of at least 3�/z inches(89 mm)in the hot water distribution line and cold water line located as close as possible <br /> to t i e storage tank. <br /> � R403.4.4 Water heater efficiencies(Mandatory). <br /> �� R403.4.4.1 Storage water heater temperature controls <br /> . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls ' <br />', capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum <br /> temperature setting range shall be from 100°F to 140°F(38°C to 60°C). <br /> . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied <br /> to electric service systems to be tumed off.A separate valve shall be provided to permit the energy supplied to the main bumer(s) <br /> of combustion types of service water heating systems to be tumed off. <br /> � R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum e�ciencies of <br />� Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. <br /> Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water <br /> heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. <br /> . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy <br /> factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of <br /> Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, <br /> and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in installed solar water <br /> heating systems should meet the following criteria: <br /> 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and <br /> 2. Be installed at an orientation within 45 degrees of true south. <br />'i p R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the <br /> Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. <br /> li Outtloor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. <br /> p R4Q�3.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. <br /> � R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the <br /> equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, <br /> based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and <br />, indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions <br />� described in Section R302.1 This code does not allow designer safety factors,provisions for future expansion or other factors <br /> which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation <br /> such as standard kitchen and bathroom exhaust systems. <br /> • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the <br /> calculated totai load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in <br /> Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the <br /> equipment shall not be less than the calculated latent load. <br /> 1 0/1 8/201 6 4:14 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4 1 Com Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.