Laserfiche WebLink
.�,, <br /> �u�' �,��°' '°�,. <br /> `va,�..,.. <br /> 1'ry�•��''S9 �0 �k������9 9}� <br /> i <br /> TABLE 1C: WOOD DECI(S-NEW CONSTRUCTION,REROOF(Tear-OfF)or RECOVER <br /> SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED ROOF COVER <br /> 7hermal earrier Roof Cover <br /> System Roof Deck MDP <br /> No. Type Attach Membrane Fasteners Fastener �P W�dth Lap Spacing Seam Weld (Psf) <br /> Spacing <br /> Min.19/32-inch thick Mule-Hide FR Deck <br /> Panei A or C or BarrlerTechnology Corp (Optional)Any Mule-Hide EHD <br /> W-5 "Blazeguard A or C"at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 12-ihch o.c. 5-inch 48-inch o.c. 1.5-inch _30.0 <br /> attached using No.8 x 2Y=-inch long thermal barrier 2.4 Seam Plates outside <br /> course thread screws s aced 6"o.c. <br /> Min.19/32-inch thick Mule-Hide FR Deck <br /> Panel A or C or Barrier Technology Corp (Optionai)Any Mule-Hide EHD 1,5-inch <br /> W-6 "Blazeguard A or C'at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5-inch 72-inch o.c. -52.5 <br /> attached using No.8 x 2h-inch long thermal barrier 2.4 Seam Plates outside <br /> course thread screws spaced 6"o.c. <br /> Min.19/32-inch thick Mule-Hide FR Deck <br /> Panel A or C or BarrierTechnology Corp (Optional)Any Mule-Hide EHD 1.5-inch <br /> W-7 "Blazeguard A or C"at max.24inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5-inch 48-inch o.c. -75.0 <br /> attached using No.8 x 2�-inch long thermal barrier 2.4 Seam Plates outside <br /> course thread screws spaced 6"o.c. <br /> Min.19/32-inch plywood at max.24inch (Optional)Any Mule-Hide EH� <br /> W-8 spans attached using 8d ring shank nails approved Loose-laid Mule-Hide TP�-c Fasteners and 6-inch o.c. 5.5-inch 48-inch o.c.(over 1.5-inch _75.0 <br /> spaced 6-inch o.c. thermal barrier 2.4 Seam Plates structural memhers) outside <br /> TABLE 1D:WOOD DECKS—TIEW CONSTRUCfION <br /> SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER <br /> System Roof Deck Roof Cover MDP <br /> • �O' Membrane Application (psf� <br /> W_9 Min.15/32-inch thicl<Mule-Hide FR Deck Panel A or C or Barrier Technology Corp"Blazeguard A or C"at <br /> max.24-inch spans attached using No.8 x 2'/:-inch long course thread screws spaced 6"o.c. Mule-Hide TPO-c WBBA 2000 -45.0 <br /> W-10 Min.19/32-inch thicl<Mule-Hide FR Deck Panel A or C or Barrier Technology Corp"Blazeguard A or C"at Mule-Hide TPO-c W BBA 2000 -52.5 <br /> max.24-inch spans attached using No.8 x 2%-inch long course thread screws spaced 6"o.c. <br /> • Ex[erfor Research and Design,LLC,d/b/a Trtnity�ERD Evaluation Report M35060.06.09-R3 for FL32772-R3 <br /> Certificate of Authorizatlon t19503 Revision 3:03/18J2015 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 18 <br /> _ _ I <br />