Laserfiche WebLink
� � � <br /> , , <br /> . FORM R405-2014 <br /> F�ORIDA ENERGY EFFICIENCY CODE FOR BUtLDING CONSTRUCTIt�N <br /> Florida Department of Business ancf Prafessianal Regulation - Residential Performance Method <br /> Project Name: Gali Elevation C 8uilder Name: dRH Express Homes � <br /> Street: ��� f�� G���e ��'" Permit Office: Ct d��P�N�'�� <br /> City,State,Zip: Zephyrhiils,F����`1 1 � J Permit Number. /��� <br /> Owner: ��/ Jurisdietion: (p( rOd� <br /> Design Location: FL,Tampa '�, County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Singls#amiiy or multipie famlly Sing}e-#amily a.Goncreie 81ock-!nt insul,Exterior R=4.1 1404.00 ft2 <br /> b.Frame-Wood,Adjacent R=1 i.D 306.22 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. tJum6er of Bedroams 4 ���lA R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1828.Oq ftz <br /> 6. Gonditianed floor area abave grade(ftz) 1828 b.NIA R= �t2 <br /> Conditioned floor area belaw grade(ftz) 0 c.N/A R= ftz <br /> i 1. Ducis R ftz <br /> 7. Windows{166.5 sqft.} DescripElon Area a.Sup:Attic,Ret:Main,AN:tU�ain 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 � <br /> SHGC: BHGC=0.31 <br /> b. U-Facfor: Dbl,ll=d.55 40.d0 ft2 12.Cooling systems kBtulhr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> , c. U-Factor: NIA ff2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Meat Pump 28.6 H8PF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SH�G: 0.3i� 14.Hot water systems <br /> a.Electric Cap:50 galions <br /> S. Fioor Types (1828.0 sqft.) Insulation Area <br /> a.Slab-On-Grade Ed e Insulation R=p.O 1828.00 ftz EF:0,950 <br /> 9 b. Conservation feaiures <br /> b.NIA R= ft2 None <br /> c.N/A �= ft2 15.Credits Pstat <br /> " Total Proposed Modified L.oads: 60.74 pq�S <br /> Glass/Floor Area: 0.091 Total Baselins Loads: 61.25 <br /> !hereby certify thai the ptans and specifications covered by Fteview of the plans and fl�*�'k�S'T,q� <br /> this calculation are in compfiance wiih the Fiorida Energy specifications covered by this ��' =� p <br /> Code. calculation indicates compliance �w rr,�" ;�;`��`;1�� <br /> with the F3arida Ener Code. � r �<<�;:-_-' ' <br /> 9Y trr,iv.. f;;."�;,�'.�„ t� <br /> PREPARED BY: �'�-�� Before construction is completed w� ;�` ''' "''" � <br /> DATE: II-4-l6 this building will be irsspected for � --,s�'�� ,�, <br /> compliance with Sectian 553.908 * � " * <br /> I hereby certify that this building,as designed,.is in compliance Florida Statutes. „t� �,S <br /> with tFte Florida Energy Gode. y��� <br /> OWNER/AGE : BUILDWG OFF! IAL: r� / - � <br /> DATE: DATE: <br /> - Compi�ance requires certlficat�on by the air handler unit manufacturer that the air handler enciasure quatifies as <br /> certified factory-sealed in accardance with R403.2.2.i. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4U2.4.1.1 and an envelope leakage <br /> test report in accordance w�th R402.4.'f.2. <br /> - Compliance with a proposed duct leakege Qn requires a Duct Leakage Test Report confirming duct leakage ta outdoars, <br /> tested!n acaardanca with Sectian 8Q3 af RESNET Siandards,is not greater than Q.Q50 Qn for whole hause. <br /> 1 1/4/201 6 3:25 PM EnergyGaugeQ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br /> �_ ' <br />