Laserfiche WebLink
� , <br /> , . - <br /> FORM R405-2014 <br /> � F�{DF�IDA ENERGY EFFICiENCY C�DE FOR BUILDING CONSTRUCTIt�t� <br /> Fiorida Department of Business and Professional Regulation - F�esidentia! Performance Msthod <br /> Project Narne: Gaii Elevation C Buiider t�arne: DRH Express Homes <br /> Street: ���p � (�f(�i �jG���� G� Permit Office: _ <br /> City,State,Zip: Zephyrhiils,F�C����^�-�1 1 , J Permit Number: <br /> Owner. ' 7`R t �lf Jurisdiction: <br /> Design Location: FL,Tampa '� County:: Pasco(Florida Climate Zone 2) <br /> 1. New cons#ruction ar existing New(From Plansj 9. Wall Types(1710.2 sqft.) Insulatian Area <br /> 2. Single family or multiple famity Single-famiiy a.Cancrete Block-!nt Insul,Exterior R_4.1 i 404A0 ftz <br /> b.Frame-Wood,tadjacent F�=11.0 306,22 ft2 <br /> 3. Number af units,if multiple family 1 c.N/A ` R� nZ <br /> 4:�Nurnber of Bedroorns q d.N!A �� �2 <br /> i0.CeitingTypes (1828.0 sqft.} lnsuiatian �Area <br /> . 5. Is this a worst case? No a.Under Attic(Vented) R-30.0 1828.00 ftz <br /> 6. Gonditioned itoor area above grade(fiz) 1828 b.NtA FC= ft2 <br /> Conditioned floor area below grade(ftz) 0 c.NIA FI- ftz <br /> 11. Ducts R {�z <br /> 7. Wlndows(166.5 sqft.} Descriptlon Area a.Sup:Attio,Ret:Main,AH:Main 8 35B <br /> a. U-Pactor: DbI,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. t1-Factar: Dk�t,U=0.55 40.00 ftz 12.Cooting systerns kBtulhr Efficiency <br /> SHGC: SHGC=0.34 a.Gentral Unit 28.6 SEER:14.00 <br /> c. U-Factar: N/A ff2 <br /> Sy��� 13. Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGG: � <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14. Hot water systems <br /> a.E3ectric Gap:50 gatlons <br /> 8. RoorTypes {i828.Q sqft.} Insuiafion Area <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Conservation features • <br /> b.NlA R� ft� None <br /> c.N/A R= ft2 15.Credits <br /> Pstat <br /> Glass/Floor Area: 0.091 <br /> Total Proposed Modified L.aads: 60.74 n��� <br /> Total Basefine Loads: 61.25 � <br /> I hereby certify that the plans and specifications covered by Review of the plans and ���7���',,q�„� <br /> this calcuEation are in compiiar�ce with the F3orida Energy specif�cations covered by this +v =_ � p <br /> Code. caiculation indicates compliance ���,°'' ='��,.� � <br /> with the F}orida Energy�ode. �• nrr���t,r;Y�;';;',::,*�", C,� <br /> PREPARED BY: �'►'��� Before construction is completed w�i � ''` '""�`�� � <br /> DATE: ��-`�-�� this building will be inspected for � �;: . ,a <br /> cotnpliance with Secfian 553.908 ,� .` � � <br /> I hereby certify that this building, as designed, is in compliance Flarida Statutes. ,,,� ,S <br /> wiih ihe Florida Energy Gode. �'{��j,�,��g,"� <br /> OWNER/AGE : - BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air hanclfer unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspectian Checklist 1n accordance with Fi402.4.1.1 and an envelope leakage <br /> tesf report in accordance w�th R402.4;2.2. <br /> - Comptiance with a proposed duct(eakage Qn requires a Duct Leakage Test Report canfirming duct leakage to outdoors, <br /> tested ln accardance wit6 Section 803 of RESNET Standards, is not greafer than O.Q50 Gtn for whole hause. <br /> 1 1/4/201 6 325 PM EnergyGaugeC�il USA-FlaRes2014 Sectian R4Q5.4.1 Compfiant Software Page 7 of 4 <br />