Laserfiche WebLink
` =�; <br /> � ' � 308 <br /> ' FORNf R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2421 sf ADS drawn Builder Name: Lennar o es Sl�,n <br /> street: 6592 Paden Wheel Street Permit Office: �(i r� c� <br /> City,State,Zip: ,FL, Permit Number � (g 2- <br /> Owner� Lennar Homes Jurisdiction: � ���� <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.0 1874.90 ftz <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4 Number of Bedrooms 4 d.N!A R= ftz <br /> 10 Ceiling Types (2421.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1901.00 ftZ <br /> 6. Conditioned floor area above grade(ft2) 2421 b.Cathedral/Single Assembly(Vented) R=30.0 520.00 ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11 Ducts R ftZ <br /> 7 Windows(230.7 sqft.) Description Area a.Sup�Attic,Ret:dining rm,AH:laundry 6 483 <br /> a. U-Factor Dbl,U=0.54 140.00 ftZ <br /> SHGC' SHGC=0.31 <br /> b. U-Factor• Dbl,U=0.58 64.00 ftx 12.Cooling systems kBtu/hr Efficiency <br /> SHGC� SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor• Dbl,U=0.56 26.67 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.283 ft. <br /> Area Weighted Average SHGC: 0.309 14 Hot water systems I <br /> B. Floor Types (2420.2 sqft.) Insulation Area a.Electric Cap:40 gallons I <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ftz b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area. 0 095 Total Proposed Modified Loads. 71.47 pASS <br /> Total Baseline Loads: 73.07 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �"C'H��7`.��. <br /> d. ,..':q �. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ' '+v.., _,:; p�, , <br /> fr�� {=�i4 <br /> Code. calculation indicates compliance c,�'�frr, ' r` n^ <br /> /. with the Florida Energy Code. � '�� � i � <br /> �' tr,fri�%;;::;�':.-'��"�'.,�� � <br /> PREPARED BY: �QV� �����'c Before construction is completed �� '4 � <br /> this buildin will be ins ected for ���' " � <br /> DATE. 9 P r:� ����;� � <br /> compliance with Section 553.908 � � � , � <br /> I hereb certi that this buildin as desi ned is in com liance Florida Statutes. �S <br /> Y fY 9, 9 P �!_:. � �� , <br /> with the Florida Energy Code. �'��W�'�` <br /> OWNER/AGENT: BUILDING OF CI . <br /> DATE. DATE. " <br /> - Compliance requires certificati n by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance.with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 1/3/2017 8:35 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 6 <br /> � <br />