My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18229
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18229
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 2:02:06 PM
Creation date
12/12/2017 2:02:04 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18229
Building Department - Name
LENNAR HOMES LLC
Address
6592 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � <br /> ' ' � 308 <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2421 sf ADS drawn Builder Name: Lennar Homes <br /> street: 6592 Paden Wheel Street Permit ottice: <br /> City,State,Zip: ,FL, Permit Number� <br /> Owner Lennar Homes Jurisdiction: <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9 Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.0 1874.90 ftz <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4 Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area Z <br /> a.UnderAttic(Vented) R=30.0 1901.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2421 b.Cathedral/Single Assembly(Vented) R=30.0 520.00 ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A . R= ft2 <br /> 11 Ducts R ft� <br /> 7. Windows(230 7 sqft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 483 <br /> a. U-Factor Dbl,U=0.54 140.00 ft2 <br /> SHGC SHGC=0.31 <br /> b. U-Factor Dbl,U=0.58 64.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor• Dbl,U=0.56 26.67 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ftz a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC• <br /> Area Weighted Average Overhang Depth. 4.283 ft. <br /> Area Weighted Average SHGC• 0.309 14 Hot water systems <br /> 8. Floor Types (2420.2 sqft.) Insulation Area a.Electric Cap�40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ftZ b. Conservation features <br /> b N/A R= ft� None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/FloorArea. 0.095 Total Proposed Modified Loads: 71.47 pASS <br /> Total Baseline Loads: 73.07 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ���1cSE S7'.q�.�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this �v ,�.{ '�i=�' p�,�, _ <br /> Code. - calculation indicates compliance �'�;i„ `' _�'� �+ . <br /> with the Florida Energy Code. F+ ��r�rr.°�%� �.+�E".�,°:���`"*�,a�� <br /> �"� /. � ��� .• �..«. � . <br /> PREPARED BY �aV� f�Wl,j'l�Vl Before construction is completed <br /> DATE: this building will be inspected for � �'���! � � � <br /> compliance with Section 553.908 ' * � � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. . � . ��� <br /> with the Florida Energy Code. �D yy�'�� <br /> OWNER/AGENT: BUILDING OFFICIAL. <br /> DATE: � � ' DATE. � <br /> � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESPIET Standards,is not greater than 0.030 Qn for whole house. <br /> 1/3/2017 8:35 AM EnergyGaugeO USA-FlaRes2014 Section R405 4 1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.