Laserfiche WebLink
;. ; <br /> 413 <br /> FORM f2405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2268 sf ADS Builder Name: LENNAR OMES <br /> street: 6611 Paden Wheel Street Permit Office: ��� p�Z��c�rh���S <br /> City,State,Zip: ,FL, Permit Number ��2�-a <br /> Owner• LENNAR HOMES Jurisdiction: � ��(e� <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9 Wall Types(2268.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1904.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 364.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft: <br /> 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2267.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2267.00 ft' <br /> 6. Conditioned floor area above grade(ftZ) 2267 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 �• R= ft <br /> z <br /> � 11 Ducts R ftZ <br /> 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 600 <br /> a. U-Factor• Dbl,U=0.54 143.00 ft2 <br /> SHGC• SHGC=0.31 <br /> b. U-Factor• Dbl,U=0.58 96.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• SHGC=0.32 a.Central Unit 34.6 SEER:15.20 <br /> c. U-Factor: Dbl,U=0.56 38.00 ftZ <br /> SHGC: SHGC=0.26 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.206 ft. <br /> Area Weighted Average SHGC• 0.309 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2267.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftZ b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ftZ �5.Credits Pstat <br /> Glass/Floor Area. 0.122 <br /> Total Proposed Modified Loads: 71.00 pASS <br /> Total Baseline Loads: 72.50 <br /> I hereby certify that the plans and specifications covered by Review of the plans and _���3ru ST,��,� <br /> this calculation are in compliance with the Florida Energy specifications covered by this �.�r ' e`y p� , <br /> Code. calculation indicates compliance ��,,r;'' '=`^''��� re, <br /> with the Florida Energy Code. rrm�:'.�%:-'�•''��;.��„'r0 <br /> � , .f.r.�,. . :� � <br /> PREPARED BY: J�G�Ve �{CD�f'1GGl Before construction is completed , <br /> DATE: this building will be inspected for � ����; � <br /> compliance with Section 553.908 ,� :� � � <br /> I hereby certify that this building,as designed is in compliance Florida Statutes. �; . " ,. ��.: .� <br /> with the Florida Energy Code. �0,�,�y� ,^('$� <br /> OWNER/AGENT: � BUILDIN O FICIAL: <br /> DATE: � � DATE: ' <br /> - Compliance requires certificatio by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 1/3/2017 9:49 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br /> L <br />