My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18230
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18230
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 2:03:08 PM
Creation date
12/12/2017 2:03:06 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18230
Building Department - Name
LENNAR HOMES LLC
Address
6611 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ � <br /> 413 <br /> FORM R405-2014 � <br /> �; <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2268 sf ADS Builder Name: LENNAR HOMES <br /> street: 6611 Paden Wheel Street � Permit Office: <br /> City,State,Zip: ,FL, Permit Number <br /> Owner LENNAR HOMES Jurisdiction: <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1904.00 ftz ' <br /> b.Frame-Wood,Adjacent R=11.0 364.00 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A 2 <br /> R= ft <br /> 4 Number of Bedrooms 4 d.N/A R= ftx <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2267.0 sqft.) Insulation Area Z <br /> a.UnderAttic(Vented) R=30.0 2267.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2267 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11 Ducts R ftz <br /> 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 600 <br /> a. U-Factor Dbl,U=0.54 143.00 ftZ <br /> ` SHGC� SHGC=0.31 <br /> b. U-Factor. Dbl,U=0.58 96.00 ftZ �2.Cooling systems kBtu/hr Efficiency , <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 ' <br /> c. U-Factor• Dbl,U=0.56 38.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ftz a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.206 ft. <br /> Area Weighted Average SHGC• 0.309 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2267.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> � c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.122 Total Proposed Modified Loads: 71.00 pASS <br /> Total Baseline Loads: 72.50 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ���hTE S7'��, <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,�' ,f`; ' �.; �Q�; <br /> Code. calculation indicates compliance �"a ri�, '� `=��`'ra`, <br /> /,,� /. with the Florida Energy Code. � lrrrrr�°'%��;;;�;_"�;•��"�„i�� <br /> PREPARED BY. �G�V� �GUI�'(�VL Before construction is completed � _ �� '` - �` .� <br /> DATE: this building will be inspected for �• ��' �� . . <br /> compliance with Section 553.908 ,� �"� - , : � <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. � <br /> Y fY 9, 9 P '��;o �ra <br /> with the Florida Energy Code. � ,i3 yy�'C�` <br /> OWNER/AGENT: BUILDING OFFI L <br /> DATE: �' ' DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> ,Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 1/3/2017 9:49 AM Ener Gau e0 USA-FlaRes2014 Section R405.4 1 Com liant Software Pa e 1 of 4 <br /> 9Y 9 P 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.