17-18231
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18231
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 2:04:02 PM
Creation date
12/12/2017 2:04:00 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18231
Building Department - Name
LENNAR HOMES LLC
Address
36125 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � =y, <br /> 126 <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 1871 sf ADS Builder Name: Lennar H es <br /> street: 36125 Stable Wilk Avenue Permit Office: Cl��`T�'�� �2�j��-��l�s <br /> City,State,Zip: ,FL, Pertnit Number: �J �!8 23( <br /> Owner• Lennar Homes Jurisdiction: � l j�� <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2361.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1152.00 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 846.44 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 362.56 ft� <br /> 4. Number of Bedrooms 4 d.N/A R= ft� <br /> 10.Ceiling Types (1090.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1090.00 ftz <br /> 6. Conditioned floor area above grade(ft2) 1870 b.N/A R= ft' <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft' <br /> 11 Ducts R ft' <br /> 7. Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374 <br /> a. U-Factor Dbl,U=0.54 87.00 ft� <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 49.69 ft' �2•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor• Dbl,U=0.56 33.33 ft� <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftz a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.369 ft. <br /> Area Weighted Average SHGC: 0.303 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1870.0 sqft.) Insulation Area <br /> EF'0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 780.00 ft' b. Conservation features <br /> b.Floor Over Other Space R=0.0 647.00 ft� None <br /> c.other(see details) R= 443.00 ftZ 15.Credits Pstat <br /> Glass/Floor Area. 0.091 Total Proposed Modified Loads: 59.69 pASS <br /> Total Baseline Loads. 61 38 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �4'S��T'�7+� <br /> this calculation are in compliance with the Florida Energy specifications covered by this �,ti ,�f, ti�,�;� t��, <br /> Code. calculation indicates compliance � .rr, ' ' ,��'��� <br /> /. with the Florida Energy Code. �% jtrtr":�',''%� ;Y=y'-:�F�.,`�-'�,,,s,t:� <br /> PREPARED BY: �aVe �����'c Before construction is completed w� , � <br /> � '���;,.. _.. d. <br /> DATE. this building will be inspected for � �"?;,; , 3�._ <br /> � �: <br /> compliance with Section 553.908 �� � � <br /> I hereb certi that this buildin ,as desi ned, is in com liance Florida Statutes. ��� ''� <br /> Y fY 9 9 P � <br /> �. <br /> with the Florida Energy Code. �Q�3 WE'�F' <br /> OWNER/AGENT: � � BUILDING Q FI AL: <br /> DATE: � DATE: <br /> - Compliance requires certifcation by the air handler unit manufacturer that the air handler enc osure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/29/2016 9:57 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.