Laserfiche WebLink
126 <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 1871 sf ADS Builder Name: Lennar Homes <br /> screet: 36125 Stable Wilk Avenue Permit Office: <br /> City,State,Zip: ,FL, Permit Number <br /> Owner• Lennar Homes Jurisdiction: <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2361.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1152.00 ft' <br /> b.Concrete Block-Int Insul,Exterior R=4.1 846.44 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 362.56 ft' <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1090.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1090.00 ft <br /> 6. Conditioned floor area above grade(ft=) 1870 b.N/A R= ft' <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11 Ducts R ft' <br /> 7. Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374 <br /> a. U-Factor: Dbl,U=0.54 87.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 49.69 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor• Dbl,U=0.56 33.33 ft� <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftz a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.369 ft. <br /> Area Weighted Average SHGC: 0.303 14 Hot water systems <br /> 8. Floor Types (1870.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 780.00 ft2 b. Conservation features <br /> b.Floor Over Other Space R=0.0 647.00 ft' None <br /> c.other(see details) R= 443.00 ftZ 15.Credits Pstat � <br /> Total Proposed Modified Loads: 59.69 pASS I <br /> Glass/Floor Area: 0.091 <br /> Total Baseline Loads: 61.38 <br /> I hereby certify that the plans and specifications covered by Review of the plans and .��'��s�'�qp,�, I <br /> this calculation are in compliance with the Flonda Energy specifications covered by this w���. i`ti`*` U�, . <br /> Code. calculation indicates compliance r,y'�Ir,, � -� �����' <br /> with the Florida Energy Code. � It�r�:�`'%::�':�",'.;�,'�"„tCi <br /> PREPARED BY: �ave ����� Before construction is completed � ` `'�� � " `�'�' <br /> this buildin will be ins ected for ���`� � � <br /> DATE. 9 P s9 !.�.��;i. ` �: . <br /> compliance with Section 553.908 ,r ��_ ;� <br /> I hereby certify that this building,as designed, i in compliance Florida Statutes. {,�; 4��5 . <br /> with the Florida Energy Code. �Qb WE� <br /> i <br /> OWNER/AGENT: BUILDING QFFICIA . <br /> DATE. DATE. � � <br /> - Compliance requires cerEification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2,1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/29l2016 9:57 AM EnergyGauge�USA-FlaRes2014 Section R4�5.4.1 Compliant Software Page 1 of 5 <br />