My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18232
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18232
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 2:05:01 PM
Creation date
12/12/2017 2:04:59 PM
Metadata
Fields
Template:
Building Department
Company Name
SIVLERADO
Building Department - Doc Type
Permit
Permit #
17-18232
Building Department - Name
LENNAR HOMES LLC
Address
36124 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.y • 208 <br /> FORM R405-2014 , <br /> FLORIDA ENERGY EFFI'CIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name. 1941 sf ADS Builder Name: Le nar Homes <br /> street: 36124 Stable Wilk Avenue Permit Office: ������q",`�� <br /> City,State,Zip� ,FL, Permit Number <br /> Owner• Lennar Homes Jurisdiction: � r�'��� <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9 Wall Types(1666.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1378.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 288.00 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z <br />, a.UnderAttic(Vented) R=30.0 1594.00 ft <br /> 6. Conditioned floor area above grade(ftz) 1936 b.Cathedral/Single Assembly(Vented) R=30.0 342.00 ftz <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11 Ducts R ftZ <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 165.7 <br /> a. U-Factor• Dbl,U=0.54 101.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor Dbl,U=0.56 23.00 ft2 <br /> SHGC• SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftz a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC• <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area EF 0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/FloorArea: 0.081 Total Proposed Modified Loads. 58.15 pASS <br /> Total Baseline Loads: 58.52 <br /> I hereby certiiy that the plans and specifications covered by Review of the plans and �'C�S7'�?, <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��� '" = -. �p�; , <br /> � <br /> Code. calculation indicates compliance � rl, ''' '"��`�` <br /> t , <br /> with the Florida Energy Code. �+ ,rtiro�.'c%;�.r?���•��,�,� � <br /> PREPARED BY. J�G�V� f�GD�YIG� Before construction is completed <br /> � _:t5�`"' .. tJ <br /> DATE: this building will be inspected for � �,� � <br /> compliance with Section 553.908 *, '� � <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. � . �', <br /> Y fY 9, 9 P �'�; ' . �}�a <br /> with the Florida Energy Code. ` OD yyE'� <br /> OWNER/AGENT. BUILDING OFFIC L. <br /> DATE: E DATE: ' <br />, - Compliance requires certification b the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br />, -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br />' test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 12/30/2016 8:53 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.